Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

被引:15
|
作者
Struffert, Tobias [1 ]
Ott, Sabine [1 ]
Adamek, Edyta [1 ]
Schwarz, Marc [1 ]
Engelhorn, Tobias [1 ]
Kloska, Stephan [1 ]
Deuerling-Zheng, Yu [2 ]
Doerfler, Arnd [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Neuroradiol, D-91054 Erlangen, Germany
[2] Siemens AG, Healthcare Sector, D-91301 Forchheim, Germany
关键词
Angiography; Flat detector computed tomography; Animal model; Multislice computed tomography; Intracranial stent; SMALL-VESSEL STENTS; ANEURYSM MODEL; COIL EMBOLIZATION; RESTENOSIS; VISUALIZATION; ANGIOPLASTY; HEMORRHAGE; STENOSES;
D O I
10.1007/s00330-011-2093-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents.
引用
收藏
页码:1779 / 1787
页数:9
相关论文
共 50 条
  • [41] Bronchial and nonbronchial systemic arteries at multi-detector row CT angiography: Comparison with conventional angiography
    Remy-Jardin, M
    Bouaziz, N
    Dumont, P
    Brillet, PY
    Bruzzi, J
    Remy, J
    RADIOLOGY, 2004, 233 (03) : 741 - 749
  • [42] Basics priciples of flat detector computed tomography (FD-CT)
    Kyriakou, Y.
    Struffert, T.
    Doerfler, A.
    Kalender, W. A.
    RADIOLOGE, 2009, 49 (09): : 811 - 819
  • [43] Feasibility of Intravenous Flat Panel Detector CT Angiography for Intracranial Arterial Stenosis
    Jeon, J. S.
    Sheen, S. H.
    Hwang, G. J.
    Kim, H. C.
    Kwon, B. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (01) : 129 - 134
  • [44] "Stent View" Flat-Detector CT and Stent-Assisted Treatment Strategies for Complex Intracranial Aneurysms
    Levitt, Michael R.
    Cooke, Daniel L.
    Ghodke, Basavaraj V.
    Kim, Louis J.
    Hallam, Danial K.
    Sekhar, Laligam N.
    WORLD NEUROSURGERY, 2011, 75 (02) : 275 - 278
  • [45] Predicting the functional significance of stenosis severity on coronary multi detector computed tomography and conventional coronary angiography
    Decramer, I.
    Sarno, G.
    Vanhoenacker, P. K.
    Wyffels, E.
    De Bruyne, B.
    Wijns, W.
    EUROPEAN HEART JOURNAL, 2008, 29 : 719 - 719
  • [46] Evaluation of rapamycin coated stents by Multi Row Detector Computed angiography: Comparison to quantitative angiographic results
    Pinto, IM
    Ishikawa, W
    Sousa, A
    Mattos, L
    Feres, F
    Abizaid, A
    Abizaid, A
    Souza, L
    Sousa, JE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 357A - 357A
  • [47] 320-Detector row CT angiography for detection and evaluation of intracranial aneurysms: Comparison with conventional digital subtraction angiography
    Wang, H.
    Li, W.
    He, H.
    Luo, L.
    Chen, C.
    Guo, Y.
    CLINICAL RADIOLOGY, 2013, 68 (01) : E15 - E20
  • [48] A novel forward projection-based metal artifact reduction method for flat-detector computed tomography
    Prell, Daniel
    Kyriakou, Yiannis
    Beister, Marcel
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21): : 6575 - 6591
  • [49] Myocardial computed tomography perfusion after Computed tomography angiography in patients with coronary stents: comparison with conventional coronary angiography
    Qin Jie
    Hao Baoshun
    Liao Hongying
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (16) : C231 - C231
  • [50] Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms
    Luo, Zhuren
    Wang, Dan
    Sun, Xilin
    Zhang, Tong
    Liu, Fang
    Dong, Dandan
    Chan, Nicholas K.
    Shen, Baozhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 118 - 122