Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

被引:15
|
作者
Struffert, Tobias [1 ]
Ott, Sabine [1 ]
Adamek, Edyta [1 ]
Schwarz, Marc [1 ]
Engelhorn, Tobias [1 ]
Kloska, Stephan [1 ]
Deuerling-Zheng, Yu [2 ]
Doerfler, Arnd [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Neuroradiol, D-91054 Erlangen, Germany
[2] Siemens AG, Healthcare Sector, D-91301 Forchheim, Germany
关键词
Angiography; Flat detector computed tomography; Animal model; Multislice computed tomography; Intracranial stent; SMALL-VESSEL STENTS; ANEURYSM MODEL; COIL EMBOLIZATION; RESTENOSIS; VISUALIZATION; ANGIOPLASTY; HEMORRHAGE; STENOSES;
D O I
10.1007/s00330-011-2093-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents.
引用
收藏
页码:1779 / 1787
页数:9
相关论文
共 50 条
  • [21] The value of flat-detector computed tomography during catheterisation of congenital heart disease
    Gloeckler, Martin
    Koch, Andreas
    Greim, Verena
    Shabaiek, Amira
    Rueffer, Andre
    Cesnjevar, Robert
    Achenbach, Stephan
    Dittrich, Sven
    EUROPEAN RADIOLOGY, 2011, 21 (12) : 2511 - 2520
  • [22] Laser-assisted flat-detector CT-guided intracranial access
    Daniel L. Cooke
    Michael R. Levitt
    Louis J. Kim
    Danial K. Hallam
    Laligam N. Sekhar
    Basavaraj V. Ghodke
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 467 - 472
  • [23] The value of flat-detector computed tomography during catheterisation of congenital heart disease
    Martin Glöckler
    Andreas Koch
    Verena Greim
    Amira Shabaiek
    Andrè Rüffer
    Robert Cesnjevar
    Stephan Achenbach
    Sven Dittrich
    European Radiology, 2011, 21 : 2511 - 2520
  • [24] Laser-assisted flat-detector CT-guided intracranial access
    Cooke, Daniel L.
    Levitt, Michael R.
    Kim, Louis J.
    Hallam, Danial K.
    Sekhar, Laligam N.
    Ghodke, Basavaraj V.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (03) : 467 - 472
  • [25] Non-invasive coronary angiography with multi-detector computed tomography: comparison to conventional X-ray angiography
    Paul Schoenhagen
    Arthur E. Stillman
    Sandy S. Halliburton
    Stacie A. Kuzmiak
    Tracy Painter
    Richard D. White
    The International Journal of Cardiovascular Imaging, 2005, 21 : 63 - 72
  • [26] Non-invasive coronary angiography with multi-detector computed tomography: comparison to conventional X-ray angiography
    Schoenhagen, P
    Stillman, AE
    Halliburton, SS
    Kuzmiak, SA
    Painter, T
    White, RD
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01): : 63 - 72
  • [27] Discrepancies in segmental and "per vessel" assessment of coronary stenoses - Comparison of Multi Detector Computed Tomography (MDCT) with conventional coronary angiography (CA)
    Zagrodzka, M
    Ryczek, R
    Zarebinski, M
    Janczak, J
    Dziuk, M
    Adamus, J
    Cholewa, M
    Twarkowski, P
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONGRESS OF RADIOLOGY OF THE INTERNATIONAL SOCIETY OF RADIOLOGY, 2004, : 675 - 679
  • [28] Flat-Detector Computed Tomography for Evaluation of Intracerebral Vasculature for Planning of Stereoelectroencephalography Electrode Implantation
    Schmidt, Richard F.
    Lang, Michael J.
    Hoelscher, Christian M.
    Jabbour, Pascal M.
    Tjoumakaris, Stavropoula I.
    Sharan, Ashwini D.
    Wu, Chengyuan
    WORLD NEUROSURGERY, 2018, 110 : E585 - E592
  • [29] Combining measurement and Monte Carlo methods for dose assessment in flat-detector CT
    Kyriakou, Y.
    Krause, J.
    Langner, O.
    Deak, P.
    Kalender, W.
    MEDICAL PHYSICS, 2007, 34 (06) : 2544 - 2544
  • [30] Flat-panel detector computed tomography for the assessment of coronary artery stents -: Phantom study in comparison with 16-slice spiral computed tomography
    Mahnken, AH
    Seyfarth, T
    Flohr, T
    Herzog, C
    Stahl, J
    Stanzel, S
    Kuettner, A
    Wildberger, JE
    Günther, RW
    INVESTIGATIVE RADIOLOGY, 2005, 40 (01) : 8 - 13