Spectrophotometric determination of iron and copper ions in industrial wastewater, cooling water and scale of power station

被引:4
|
作者
Ghafar, Hany H. Abdel [1 ,2 ]
Mohamed, Gehad G. [3 ]
Abd El-Salam, Magdy [4 ]
El-Sayed, Abdel-Aziz Y. [5 ]
机构
[1] King Abdulaziz Univ, Dept Chem, Fac Sci & Arts Khulais, Jeddah 21413, Saudi Arabia
[2] Natl Res Ctr, Water Pollut Res Dept, Giza 12622, Egypt
[3] Cairo Univ, Dept Chem, Fac Sci, Giza 12613, Egypt
[4] Minist Elect & Energy, Cent Chem Lab, Cairo, Egypt
[5] Al Azhar Univ, Dept Chem, Fac Sci, Assiut, Egypt
关键词
Spectrophotometry; Boilers; Iron and copper determination; Water analysis; STANDARD ADDITION METHOD; SPECTROMETRIC DETERMINATION; PHARMACEUTICAL SAMPLES; MICELLAR MEDIA; IRON(III); EXTRACTION; NICKEL; PRECONCENTRATION; LIGANDS; COMPLEX;
D O I
10.1080/19443994.2014.913207
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Sensitive and selective spectrophotometric procedures were proposed for the determination of Fe(III) and Cu(II) using simple chromogenic reagents. The procedure of iron determination was based on the formation of ternary complex between Fe(III) and 4,7-diphenyl-1,10-bathophenanthroline (DPBP)-eosin in acid medium. On the other hand, the procedure of copper (II) determination was based on the formation of ternary complex between Cu(II) and 4,7-diphenyl-1,10-bathophenanthroline (DPBP)-Eriochrome Black-T (EBT) in alkaline medium. The ternary complexes were extracted in the presence of cetyltrimethyl ammonium bromide with chloroform. The molar absorptivities of the Fe(III)-DPBP-eosin and Cu(II)-DPBP-EBT ternary complexes were 2.23 center dot 10(5) and 9.35 center dot 10(4 )L mol(-1) cm(-1) at 542 and 565 nm, respectively. Beer's law is valid over the concentration ranges from 0.280 to 7.814 and from 0.320 to 8.260 mu g mL(-1) for Fe(III) and Cu(II), respectively. Sandell sensitivity (0.0025 and 0.0679 ng cm(-2)), relative standard deviation (0.257-1.94 and 0.305-1.85), limits of detection (0.076 and 0.045 mu g mL(-1)) and quantification (0.253 and 0.150 mu g mL(-1)) for Fe(III) and Cu(II) ions, respectively, are calculated. The procedures are applied for the determination of Fe(III) and Cu(II) in different polluted water sources, drinking water, river water as well as cooling water and boiler scales. The results obtained are compared with those obtained using atomic absorption spectroscopy. The effects of different tolerances are studied in the presence of masking agents.
引用
收藏
页码:96 / 106
页数:11
相关论文
共 50 条
  • [31] Barking Reach Power Station cooling water system
    Evans, JF
    Hodgkins, DJ
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 1997, 120 (01) : 15 - 26
  • [32] Removal of iron, zinc, and nickel-ions using nano bentonite and its applications on power station wastewater
    Ahmed, A. M.
    Ayad, Mohamed, I
    Eledkawy, Mohamed A.
    Darweesh, M. A.
    Elmelegy, Essam M.
    HELIYON, 2021, 7 (02)
  • [33] Determination of the cause of a damage to the boiler of an industrial power station
    Pfander, M
    PRAKTISCHE METALLOGRAPHIE-PRACTICAL METALLOGRAPHY, 2003, 40 (05): : 257 - 261
  • [35] SPECTROPHOTOMETRIC DETERMINATION OF IRON, VANADIUM, NICKEL, COPPER AND LEAD IN PETROCHEMICALS
    HULANICKI, A
    KARWOWSKA, R
    CHEMIA ANALITYCZNA, 1977, 22 (04): : 637 - 644
  • [36] SPECTROPHOTOMETRIC TITRATIONS WITH ETHYLENEDIAMINETETRAACETIC ACID - DETERMINATION OF IRON, COPPER, AND NICKEL
    SWEETSER, PB
    BRICKER, CE
    ANALYTICAL CHEMISTRY, 1953, 25 (02) : 253 - 255
  • [37] SPECTROPHOTOMETRIC DETERMINATION OF NICKEL COBALT COPPER IRON AND ZINC IN NIOBIUM
    GROSSMANN, O
    GROSSERU.H
    ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1968, 233 (01): : 14 - +
  • [38] Simultaneous spectrophotometric determination of iron and copper using ferroin reagents
    Teixeira, Leonardo S. G.
    Brasileiro, Joao F.
    Borges, Mario M., Jr.
    Cordeiro, Paulo W. L.
    Rocha, Sarah A. N.
    Costa, Antonio C. Spinola
    QUIMICA NOVA, 2006, 29 (04): : 741 - 745
  • [39] Spectrophotometric determination of trace copper in water samples with thiornichlersketone
    Fu, Dayou
    Yuan, Dong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 66 (02) : 434 - 437
  • [40] Synchronous Determination of Copper, Iron, Nickel, Cobalt, Gold and Silver in Industrial wastewater by ICP-AES
    Qu, Wei
    Hu, Yihanna
    Liu, Shuang
    Zhou, Chengying
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MATERIAL, MECHANICAL AND MANUFACTURING ENGINEERING, 2015, 27 : 477 - 480