Task-based quantification of image quality using a model observer in abdominal CT: a multicentre study

被引:19
|
作者
Racine, Damien [1 ]
Ryckx, Nick [1 ]
Ba, Alexandre [1 ]
Becce, Fabio [2 ]
Viry, Anais [1 ]
Verdun, Francis R. [1 ]
Schmidt, Sabine [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Rue Grand Pre 1, CH-1007 Lausanne, Switzerland
[2] Lausanne Univ Hosp, Dept Diagnost & Intervent Radiol, Rue Bugnon 46, CH-1011 Lausanne, Switzerland
关键词
Abdominal computed tomography; Image quality; Model observer; Standardisation; Task-based assessment; STATISTICAL ITERATIVE RECONSTRUCTION; LOW-CONTRAST DETECTABILITY; FILTERED BACK-PROJECTION; LOW-TUBE-VOLTAGE; NOISE; OPTIMIZATION; PERFORMANCE; RESOLUTION; ALGORITHM; PHANTOM;
D O I
10.1007/s00330-018-5518-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveWe investigated the variability in diagnostic information inherent in computed tomography (CT) images acquired at 68 different CT units, with the selected acquisition protocols aiming to answer the same clinical question.MethodsAn anthropomorphic abdominal phantom with two optional rings was scanned on 68 CT systems from 62 centres using the local clinical acquisition parameters of the portal venous phase for the detection of focal liver lesions. Low-contrast detectability (LCD) was assessed objectively with channelised Hotelling observer (CHO) using the receiver operating characteristic (ROC) paradigm. For each lesion size, the area under the ROC curve (AUC) was calculated and considered as a figure of merit. The volume computed tomography dose index (CTDIvol) was used to indicate radiation dose exposure.ResultsThe median CTDIvol used was 5.8 mGy, 10.5 mGy and 16.3 mGy for the small, medium and large phantoms, respectively. The median AUC obtained from clinical CT protocols was 0.96, 0.90 and 0.83 for the small, medium and large phantoms, respectively.ConclusionsOur study used a model observer to highlight the difference in image quality levels when dealing with the same clinical question. This difference was important and increased with growing phantom size, which generated large variations in patient exposure. In the end, a standardisation initiative may be launched to ensure comparable diagnostic information for well-defined clinical questions. The image quality requirements, related to the clinical question to be answered, should be the starting point of patient dose optimisation.Key Points center dot Model observers enable to assess image quality objectively based on clinical tasks.center dot Objective image quality assessment should always include several patient sizes.center dot Clinical diagnostic image quality should be the starting point for patient dose optimisation.center dot Dose optimisation by applying DRLs only is insufficient for ensuring clinical requirements.
引用
收藏
页码:5203 / 5210
页数:8
相关论文
共 50 条
  • [31] Task-Based Image Quality Assessment in Radiation Therapy: Initial Characterization and Demonstration with CT Simulation Images
    Dolly, Steven R.
    Anastasio, Mark A.
    Yu, Lifeng
    Li, Hua
    MEDICAL IMAGING 2017: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2017, 10136
  • [32] An Improved Index of Image Quality for Task-based Performance of CT Iterative Reconstruction across Three Commercial Implementations
    Christianson, Olav
    Chen, Joseph J. S.
    Yang, Zhitong
    Saiprasad, Ganesh
    Dima, Alden
    Filliben, James J.
    Peskin, Adele
    Trimble, Christopher
    Siegel, Eliot L.
    Samei, Ehsan
    RADIOLOGY, 2015, 275 (03) : 725 - 734
  • [33] Parallelization Using Task Parallel Library with Task-Based Programming Model
    Hei, Xinhong
    Zhang, Jinlong
    Wang, Bin
    Jin, Haiyan
    Giacaman, Nasser
    2014 5TH IEEE INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING AND SERVICE SCIENCE (ICSESS), 2014, : 653 - 656
  • [34] Metrics of medical image quality: task-based model observers vs. image discrimination/perceptual difference models
    Eckstein, MP
    Zhang, Y
    Pham, BT
    MEDICAL IMAGING 2004: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2004, 5372 : 42 - 52
  • [35] Practical approaches to approximating MTF and NPS in CT with an example application to task-based observer studies
    Bujila, Robert
    Fransson, Annette
    Poludniowski, Gavin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 16 - 25
  • [36] A comparative study of two model observer calculation methods to evaluate CT image quality
    de Buren, P.
    Racine, D.
    Gianolini, S.
    Lutters, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 872 - 872
  • [37] Impact of four kVp combinations available in a dual-source CT on the spectral performance of abdominal imaging: A task-based image quality assessment on phantom data
    Greffier, Joel
    Frandon, Julien
    Sadate, Alexandre
    Akessoul, Philippe
    Belaouni, Asmaa
    Beregi, Jean-Paul
    Dabli, Djamel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 243 - 254
  • [39] Comparison of two deep learning image reconstruction algorithms in chest CT images: A task-based image quality assessment on phantom data
    Greffier, Joel
    Frandon, Julien
    Si-Mohamed, Salim
    Dabli, Djamel
    Hamard, Aymeric
    Belaouni, Asmaa
    Akessoul, Philippe
    Besse, Francis
    Guiu, Boris
    Beregi, Jean-Paul
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 21 - 30
  • [40] Task-based measures of image quality and their relation to radiation dose and patient risk
    Barrett, Harrison H.
    Myers, Kyle J.
    Hoeschen, Christoph
    Kupinski, Matthew A.
    Little, Mark P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : R1 - R75