Optical Assessment of Soft Contact Lens Edge-Thickness

被引:9
|
作者
Tankam, Patrice [1 ,2 ]
Won, Jungeun [3 ]
Canavesi, Cristina [4 ]
Cox, Ian [2 ,5 ]
Rolland, Jannick P. [1 ,2 ,3 ,4 ]
机构
[1] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[2] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
[4] LighTopTech Corp, West Henrietta, NY USA
[5] IGC Consulting, New York, NY USA
基金
美国国家科学基金会;
关键词
soft contact lens; edge-thickness; optical coherence tomography; microscopy; optical metrology; TFOS INTERNATIONAL WORKSHOP; COHERENCE TOMOGRAPHY; IN-VIVO; HIGH-SPEED; DISCOMFORT; MICROSCOPY; EPITHELIUM; QUALITY; VISION; DESIGN;
D O I
10.1097/OPX.0000000000000892
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-mu m imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. Methods. A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. Results. The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 mu m. Conclusions. The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCMin the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.
引用
收藏
页码:987 / 996
页数:10
相关论文
共 50 条
  • [1] Stickiness, edge-thickness, and clique-thickness in graphs
    Kloks, T
    Lee, CM
    Liu, JP
    JOURNAL OF INFORMATION SCIENCE AND ENGINEERING, 2004, 20 (02) : 207 - 217
  • [2] Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear
    Del Aguila-Carrasco, Antonio J.
    Dominguez-Vicent, Alberto
    Perez-Vives, Cari
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (05) : 385 - 390
  • [3] Assessment of the reliability (repeatability) of corneal thickness measurements in soft contact lens wearers using a non-contact specular microscope
    Doughty, Michael J.
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (04):
  • [4] Effects of the peripheral thickness of soft contact lenses on tears and eye dryness during soft contact lens wear
    Yokoi, Norihiko
    Sakai, Rieko
    Yamaguchi, Hiroyuki
    Kinoshita, Shigeru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [5] Evaluation of the effect of soft contact lens edge shape on conjunctival epithelium
    Szczesna-Iskander, Dorota
    Iskander, D. Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [6] Wearing time affects post-lens tear thickness under a soft contact lens
    Polse, KA
    Lin, MC
    Han, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U213 - U213
  • [7] OPTICAL ADVANTAGE OF A SOFT CONTACT-LENS IN SPECULAR MICROSCOPY
    SHERRARD, ES
    BUCKLEY, RJ
    ARCHIVES OF OPHTHALMOLOGY, 1981, 99 (03) : 511 - 512
  • [8] Distribution of Baseline Soft Contact Lens Power by Age in the Contact Lens Assessment in Youth (CLAY) Study
    Kinoshita, B. T.
    Larry, D.
    Mitchell, G. L.
    Wagner, H.
    Chalmers, R.
    Jansen, M.
    Richdale, K.
    Sorbara, L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [9] Impact of Soft Contact Lens Edge Design and Midperipheral Lens Shape on the Epithelium and Its Indentation With Lens Mobility
    Wolffsohn, James S.
    Drew, Thomas
    Dhallu, Sandeep
    Sheppard, Amy
    Hofmann, Greg J.
    Prince, Mark
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (09) : 6190 - 6196
  • [10] Multicenter Testing of a Risk Assessment Survey for Soft Contact Lens Wearers With Adverse Events: A Contact Lens Assessment in Youth Study
    Sorbara, Luigina
    Zimmerman, Aaron B.
    Mitchell, G. Lynn
    Richdale, Kathryn
    Lam, Dawn Y.
    Kinoshita, Beth T.
    Chalmers, Robin L.
    Wagner, Heidi
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 (01): : 21 - 28