Contrast-Enhanced Dual-Energy CT of Gastrointestinal Stromal Tumors Is Iodine-Related Attenuation a Potential Indicator of Tumor Response?

被引:104
|
作者
Apfaltrer, Paul [1 ]
Meyer, Mathias [1 ]
Meier, Caroline [1 ]
Henzler, Thomas [1 ]
Barraza, John M., Jr. [2 ]
Dinter, Dietmar J. [1 ]
Hohenberger, Peter [3 ]
Schoepf, U. Joseph [2 ]
Schoenberg, Stefan O. [1 ]
Fink, Christian [1 ]
机构
[1] Univ Heidelberg, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[2] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[3] Univ Heidelberg, Med Fac Mannheim, Dept Surg, Div Surg Oncol & Thorac Surg, D-68167 Mannheim, Germany
关键词
dual-energy CT; gastrointestinal stromal tumors; response evaluation; RECIST; IMATINIB MESYLATE; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; PATIENT SIZE; SOLID TUMORS; RENAL MASSES; ABDOMEN; APPROPRIATE; PROGRESSION; SURVIVAL;
D O I
10.1097/RLI.0b013e31823003d2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To assess the correlation of true nonenhanced (TNE) and virtually nonenhanced (VNE) images of abdominal dual-energy computed tomography (DECT) in patients with metastatic gastrointestinal stromal tumors (GIST), and further to investigate the correlation of iodine-related attenuation (IRA) of DECT with the Choi criteria. Material and Methods: Twenty-four consecutive patients (5 women aged 61 +/- 10 years) with metastatic GIST underwent DECT of the abdomen (80 kV, 140 kV) using first-generation dual-source computed tomography (CT). All patients had at least one or more liver lesions (median, 4; maximum, 9). Image data were processed with a dedicated DECT software algorithm designed for evaluation of iodine distribution in soft tissue lesions, and VNE CT images were generated. The tumor density (according to Choi criteria) and the maximum transverse diameter of the lesions (according to Response Evaluation Criteria in Solid Tumors [RECIST]) were determined. TNE and VNE lesion attenuation and Choi criteria and IRA were correlated with each other. Results: A total of 291 liver lesions were evaluated, of which 220 were cystic and 71 were solid. The mean lesion size was 4.5 +/- 3.2 cm (1.1-18.7 cm). The mean attenuation of all lesions was significantly higher in the TNE images than in the VNE images (P = 0.0001). Pearson statistics revealed an excellent correlation of r = 0.843 (P = 0.0001) between IRA and Choi criteria for all lesions. DECT showed significantly higher IRA in progressive (23.3 +/- 9.5 HU) lesions compared with stable or regressive (17.8 +/- 9.1 HU) lesions (P = 0.0185). Similarly, the Choi criteria differed significantly between progressive (39.9 +/- 12.8 HU) and stable/regressive (31.1 +/- 10.3 HU) lesions (P = 0.0003). Conclusions: DECT is a promising imaging method for the assessment of treatment response in GIST, as IRA might be a more robust response parameter than the Choi criteria. VNE CT data calculated from DECT may eliminate the need for acquisition of a separate unenhanced data set.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 50 条
  • [21] Assessing tumor vascularization as a potential biomarker of imatinib resistance in gastrointestinal stromal tumors by dynamic contrast-enhanced magnetic resonance imaging
    Lorena Consolino
    Dario Livio Longo
    Marianna Sciortino
    Walter Dastrù
    Sara Cabodi
    Giovanni Battista Giovenzana
    Silvio Aime
    Gastric Cancer, 2017, 20 : 629 - 639
  • [22] Assessing tumor vascularization as a potential biomarker of imatinib resistance in gastrointestinal stromal tumors by dynamic contrast-enhanced magnetic resonance imaging
    Consolino, Lorena
    Longo, Dario Livio
    Sciortino, Marianna
    Dastru, Walter
    Cabodi, Sara
    Giovenzana, Giovanni Battista
    Aime, Silvio
    GASTRIC CANCER, 2017, 20 (04) : 629 - 639
  • [23] Potential of spectral imaging generated by contrast-enhanced dual-energy CT for lung cancer histopathological classification - A preliminary study
    Sasaki, Tomoaki
    Oda, Shioto
    Kuno, Hirofumi
    Hiyama, Takashi
    Taki, Tetsuro
    Takahashi, Shugo
    Ishii, Genichiro
    Tsuboi, Masahiro
    Kobayashi, Tatsushi
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2025, 14
  • [24] Radiomics Nomogram Based on Contrast-enhanced CT to Predict the Malignant Potential of Gastrointestinal Stromal Tumor: A Two-center Study
    Song, Yancheng
    Li, Jie
    Wang, Hexiang
    Liu, Bo
    Yuan, Chentong
    Liu, Hao
    Zheng, Ziwen
    Min, Fanyi
    Li, Yu
    ACADEMIC RADIOLOGY, 2022, 29 (06) : 806 - 816
  • [25] Semiquantitative iodine uptake measurement of metastases with dual-energy CT - A potential marker for monitoring targeted therapies in advanced gastrointestinal stromal tumours?
    Schramm, N.
    Schlemmer, M.
    Englhart, E.
    Nikolaou, K.
    Becker, C.
    Reiser, M.
    Berger, F.
    ONKOLOGIE, 2010, 33 : 184 - 184
  • [26] Utility of noncontrast MRI in the detection and risk grading of gastrointestinal stromal tumor: a comparison with contrast-enhanced CT
    Zhou, Ziling
    Lu, Jingyu
    Morelli, John N.
    Hu, Daoyu
    Li, Zhen
    Xiao, Peng
    Hu, Xuemei
    Shen, Yaqi
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (06) : 2453 - +
  • [27] Dual-energy CT Imaging Using a Single-energy CT Data via Deep Learning: A Contrast-enhanced CT Study
    Zhao, W.
    Lv, T.
    Chen, Y.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S43 - S43
  • [28] THE RELATIONSHIP BETWEEN IODINE-RELATED ATTENUATION OF DUAL-ENERGY CT AND STANDARDIZED UPTAKE VALUE OF 18FDG PET-CT IN PATIENTS WITH NON-SMALL CELL LUNG CANCER
    Kim, Eun Young
    Kim, Young Saing
    Lee, Hae Joon
    Park, Inkeun
    Ahn, Hee Kyung
    Cho, Eun Kyung
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S1270 - S1270
  • [29] Gastrointestinal stromal tumors: associations between contrast-enhanced CT images and KIT exon 11 gene mutation
    Liu, Xijiao
    Yin, Yuan
    Wang, Xiaozhou
    Yang, Caiwei
    Wan, Shang
    Yin, Xiaonan
    Wu, Tingfan
    Chen, Huijiao
    Xu, Zhongming
    Li, Xin
    Song, Bin
    Zhang, Bo
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (19)
  • [30] Detection of moderate hepatic steatosis on contrast-enhanced dual-source dual-energy CT: Role and accuracy of virtual non-contrast CT
    Catania, Roberta
    Jia, Leo
    Haghshomar, Maryam
    Miller, Frank H.
    Borhani, Amir A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172