Subjective visual acuity with simulated defocus

被引:18
|
作者
Dehnert, Anne [1 ]
Bach, Michael [1 ]
Heinrich, Sven P. [1 ]
机构
[1] Univ Augenklin, Sekt Funkt Sehforsch, Freiburg, Germany
关键词
defocus; dioptric blur; Fourier-optical model; visual acuity;
D O I
10.1111/j.1475-1313.2011.00857.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Artificial degradation of vision by inducing dioptric blur is frequently used for evaluating diagnostic equipment. However, the use of lenses is prone to errors as it is adversely affected by eyelid squinting, pupil size, and imprecise lens position. The alternative is a degradation of the stimuli themselves based on a Fourier-optical mathematical model. With this, however, perceptual effects such as 'simultaneous blur' induced by the surround may affect acuity. We tested whether both methods, lens induced defocus and mathematical stimulus degradation, yield concordant results. Methods: We compared both methods in normal subjects, measuring Landolt C acuity at five different levels of defocus from 0 to 8 dioptres. The pupil size was determined individually, chromatic aberrations were avoided by using a monochromatic approach, and a correction for spectacle magnification was included. Otherwise, the experimental design was kept deliberately simple to remain comparable to typical applications. Results: With the major sources of error associated with the use of lenses being accounted for, both methods yield similar mean results with differences in acuity ranging from <0.001 to 0.054 logMAR (0.2-13%). Conclusion: Using mathematically simulated defocus is a viable option if both reasonable accuracy and ease of use are required. The fact that the application of the mathematical model only blurs the stimulus itself, but not the surrounding environment, does not appear to be detrimental to the method.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [31] Effect of Reduced Visual Acuity on Simulated Flight Performance
    Lynch, Allison
    Cao, Shi
    Niechwiej-Szedo, Ewa
    Kearns, Suzanne
    Irving, Elizabeth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [32] Visual acuity of dentists under simulated clinical conditions
    Eichenberger, Martina
    Perrin, Philippe
    Neuhaus, Klaus W.
    Bringolf, Ueli
    Lussi, Adrian
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (03) : 725 - 729
  • [33] Population-based visual acuity in the presence of defocus well predicted by classical theory
    Weeber, Henk A.
    Featherstone, Kristen A.
    Piers, Patricia A.
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (04)
  • [34] STATISTICAL RELIABILITY OF VISUAL-ACUITY AND CONTRAST SENSITIVITY CHANGES THAT ACCOMPANY IMAGE DEFOCUS
    BRADLEY, A
    KATO, M
    THIBOS, LN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S633 - S633
  • [35] Impact of temporal fluctuations in optical defocus on visual acuity: Empirical results and modeling outcomes
    Goswami, Sabyasachi
    Bharadwaj, Shrikant R.
    JOURNAL OF VISION, 2023, 23 (03):
  • [36] Evaluation of defocus curve performance with two visual acuity testing systems: ETDRS and FrACT
    Tarrant, Janice
    Thomas, Eugenia
    Tsai, Linda
    Kasthurirangan, Sanjeev
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [37] Visual acuity with computer simulated and lens-induced astigmatism
    Remon, Laura
    Benlloch, Josefa
    Pons, Amparo
    Monsoriu, Juan A.
    Furlan, Walter D.
    OPTICA APPLICATA, 2014, 44 (04) : 521 - 531
  • [38] Influence of Motion Smear on Visual Acuity in Simulated Infantile Nystagmus
    Chung, Susana T. L.
    LaFrance, Martin W.
    Bedell, Harold E.
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (02) : 200 - 207
  • [39] Evaluation of Agreement Between Sweep Visual Evoked Potential Testing and Subjective Visual Acuity
    Polat, Osman Ahmet
    Sener, Hidayet
    Cetinkaya, Zekeriya
    Arda, Hatice
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2023, 53 (05): : 289 - 293
  • [40] Potential vision testing - the relationship between visual acuity and Vernier acuity in the presence of simulated cataract
    Quaid, P
    Stonier, C
    Cox, MJ
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2002, 22 (06) : 469 - 481