Subjective visual acuity with simulated defocus

被引:18
|
作者
Dehnert, Anne [1 ]
Bach, Michael [1 ]
Heinrich, Sven P. [1 ]
机构
[1] Univ Augenklin, Sekt Funkt Sehforsch, Freiburg, Germany
关键词
defocus; dioptric blur; Fourier-optical model; visual acuity;
D O I
10.1111/j.1475-1313.2011.00857.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Artificial degradation of vision by inducing dioptric blur is frequently used for evaluating diagnostic equipment. However, the use of lenses is prone to errors as it is adversely affected by eyelid squinting, pupil size, and imprecise lens position. The alternative is a degradation of the stimuli themselves based on a Fourier-optical mathematical model. With this, however, perceptual effects such as 'simultaneous blur' induced by the surround may affect acuity. We tested whether both methods, lens induced defocus and mathematical stimulus degradation, yield concordant results. Methods: We compared both methods in normal subjects, measuring Landolt C acuity at five different levels of defocus from 0 to 8 dioptres. The pupil size was determined individually, chromatic aberrations were avoided by using a monochromatic approach, and a correction for spectacle magnification was included. Otherwise, the experimental design was kept deliberately simple to remain comparable to typical applications. Results: With the major sources of error associated with the use of lenses being accounted for, both methods yield similar mean results with differences in acuity ranging from <0.001 to 0.054 logMAR (0.2-13%). Conclusion: Using mathematically simulated defocus is a viable option if both reasonable accuracy and ease of use are required. The fact that the application of the mathematical model only blurs the stimulus itself, but not the surrounding environment, does not appear to be detrimental to the method.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 50 条
  • [21] The effect of optical defocus on the test-retest variability of visual acuity measurements
    Rosser, D
    Murdoch, I
    Cousens, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U548 - U548
  • [22] The effect of optical defocus on the test-retest variability of visual acuity measurements
    Rosser, DA
    Murdoch, IE
    Cousens, SN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (04) : 1076 - 1079
  • [23] Fast Measure of Visual Acuity and Contrast Sensitivity Defocus Curves with an iPad Application
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Tauste, Ana
    Albarran, Cesar
    Basterra, Inaki
    Pinero, David
    OPEN OPHTHALMOLOGY JOURNAL, 2019, 13 : 15 - 22
  • [24] Subjective measurements of visual acuity using vanishing figures
    Koskin, S. A.
    Boiko, E. V.
    Sobolev, A. F.
    Shelepin, Y. E.
    PERCEPTION, 2006, 35 : 129 - 129
  • [25] VISUAL ACUITY IN MONKEYS - A MONOCULAR AND BINOCULAR SUBJECTIVE TECHNIQUE
    FARRER, DN
    GRAHAM, ES
    VISION RESEARCH, 1967, 7 (9-10) : 743 - &
  • [27] SUBJECTIVE AND OBJECTIVE VISUAL-ACUITY TESTING TECHNIQUES
    KHAN, SG
    CHEN, KF
    FRENKEL, M
    ARCHIVES OF OPHTHALMOLOGY, 1976, 94 (12) : 2086 - 2091
  • [28] Spatial frequency sweep pattern reversal VER acuity vs Snellen visual acuity: Effect of optical defocus
    Katsumi, O
    Arai, M
    Wajima, R
    Denno, S
    Hirose, T
    VISION RESEARCH, 1996, 36 (06) : 903 - 909
  • [29] Visual Acuity of Simulated Thalamic Visual Prostheses in Normally Sighted Humans
    Bourkiza, Bechir
    Vurro, Milena
    Jeffries, Ailsa
    Pezaris, John S.
    PLOS ONE, 2013, 8 (09):
  • [30] Visual acuity of dentists under simulated clinical conditions
    Martina Eichenberger
    Philippe Perrin
    Klaus W. Neuhaus
    Ueli Bringolf
    Adrian Lussi
    Clinical Oral Investigations, 2013, 17 : 725 - 729