Implementation of a digital data readout system for double-sided silicon strip detectors for ion and alpha particle spectroscopy

被引:0
|
作者
Maendl, R. R. [1 ,2 ,3 ]
Ackermann, D. [2 ]
Hessberger, F. P. [2 ,3 ]
Schmidt, K. [1 ]
Zimmermann, L. [1 ]
机构
[1] Frankfurt Univ Appl Sci, Frankfurt, Germany
[2] GSI Helmholtzzentrum Schwerionenforschung, Darmstadt, Germany
[3] Helmholtz Inst, Mainz, Germany
关键词
D O I
10.1088/1742-6596/364/1/012089
中图分类号
O59 [应用物理学];
学科分类号
摘要
The experimental investigation of superheavy elements, one of the prominent research areas of the GSI Helmholtzzentrum fur Schwerionenforschung (GSI), has reached a region of short-lived nuclei with expected lifetimes of the order of 1 mu s. As signal processing times for conventional analogue front-end electronics are typically longer than 10 mu s, new developments are mandatory. Continuously sampling ADCs with virtually no dead time are presently being implemented for various signal processing applications in particle and photon spectroscopy. In this paper, a new flash-ADC based data acquisition system (DAQ) is presented. It has been tested using an alpha source and heavy ion reaction measurements at GSI's UNILAC accelerator facility. In addition, a novel analysis algorithm has been implemented thus increasing the sensitive area of the double-sided silicon strip detector (DSSD) in use.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] STUDIES OF A DOUBLE-SIDED SILICON MICROSTRIP SYSTEM WITH ANALOG VLSI READOUT
    WOOD, M
    GUTIERREZ, P
    KALBFLEISCH, G
    KAPLAN, D
    KARCHIN, P
    KUEHLER, J
    LIAPIS, C
    MCCLIMENT, E
    SINOTT, J
    SKUBIC, P
    VAUGHAN, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01): : 264 - 268
  • [42] Irradiation tests of double-sided silicon strip detectors with a special guard ring structure
    Abt, I
    Andricek, L
    Bauer, C
    Baumann, I
    Fox, H
    Halley, A
    Knopfle, KT
    Kroha, H
    Richter, RH
    Riechmann, K
    Rietz, M
    Rubsam, R
    Seywerd, H
    StDenis, R
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 28 - 32
  • [43] Irradiation tests of double-sided silicon strip detectors with a special guard ring structure
    Abt, I
    Andricek, L
    Bauer, C
    Fox, H
    Halley, A
    Kroha, H
    Richter, RH
    Riechmann, K
    Rietz, M
    Rubsam, R
    Seywerd, H
    StDenis, R
    Baumann, I
    Knopfle, KT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1113 - 1118
  • [44] DOUBLE-SIDED CAPACITIVELY COUPLED SILICON STRIP DETECTORS ON A 100MM WAFER
    BRENNER, R
    HIETANEN, I
    LINDGREN, J
    ORAVA, R
    RONNQVIST, C
    SCHULMAN, T
    TUUVA, T
    VOUTILAINEN, M
    ANDERSSON, M
    LEINONEN, K
    RONKAINEN, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3): : 502 - 506
  • [45] A DOUBLE-SIDED SILICON STRIP DETECTOR SYSTEM FOR PROTON RADIOACTIVITY STUDIES
    SELLIN, PJ
    WOODS, PJ
    BRANFORD, D
    DAVINSON, T
    DAVIS, NJ
    IRELAND, DG
    LIVINGSTON, K
    PAGE, RD
    SHOTTER, AC
    HOFMANN, S
    HUNT, RA
    JAMES, AN
    HOTCHKIS, MAC
    FREER, MA
    THOMAS, SL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 311 (1-2): : 217 - 223
  • [46] Performance of double-sided CdTe strip detectors for gamma-ray imaging and spectroscopy
    Ishikawa, S.
    Watanabe, S.
    Aono, H.
    Odaka, H.
    Sugimoto, S.
    Takeda, S.
    Takahashi, T.
    Okuyama, S.
    Nakazawa, K.
    Tanaka, T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5247 - +
  • [47] A DOUBLE-SIDED SILICON STRIP DETECTOR WITH CAPACITIVE READOUT AND A NEW METHOD OF INTEGRATED BIAS COUPLING
    HOLL, P
    KEMMER, J
    PRECHTEL, U
    ZIEMANN, T
    HAUFF, D
    LUTZ, G
    SCHWARZ, AS
    STRUDER, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 251 - 255
  • [48] Double-sided silicon detectors using N-side pad readout for the CMS silicon inner tracker
    Wheadon, R
    Tonelli, G
    Verdini, PG
    DellOrso, R
    Bagliesi, G
    Vannini, C
    Hall, G
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 541 - 543
  • [49] Utilization of Double-Sided Silicon Strip Detectors within the PANDA Micro-Vertex-Detector
    Wuerschig, Thomas
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1490 - 1494
  • [50] Efficiency and noise measurements of non-uniformly irradiated double-sided silicon strip detectors
    Dubbs, T
    Kashigin, S
    Kratzer, M
    Kroeger, W
    Pulliam, T
    Sadrozinski, HFW
    Schwab, M
    Spencer, E
    Wichmann, R
    Wilder, M
    Unno, Y
    Ohsugi, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01): : 174 - 178