Implementation of a digital data readout system for double-sided silicon strip detectors for ion and alpha particle spectroscopy

被引:0
|
作者
Maendl, R. R. [1 ,2 ,3 ]
Ackermann, D. [2 ]
Hessberger, F. P. [2 ,3 ]
Schmidt, K. [1 ]
Zimmermann, L. [1 ]
机构
[1] Frankfurt Univ Appl Sci, Frankfurt, Germany
[2] GSI Helmholtzzentrum Schwerionenforschung, Darmstadt, Germany
[3] Helmholtz Inst, Mainz, Germany
关键词
D O I
10.1088/1742-6596/364/1/012089
中图分类号
O59 [应用物理学];
学科分类号
摘要
The experimental investigation of superheavy elements, one of the prominent research areas of the GSI Helmholtzzentrum fur Schwerionenforschung (GSI), has reached a region of short-lived nuclei with expected lifetimes of the order of 1 mu s. As signal processing times for conventional analogue front-end electronics are typically longer than 10 mu s, new developments are mandatory. Continuously sampling ADCs with virtually no dead time are presently being implemented for various signal processing applications in particle and photon spectroscopy. In this paper, a new flash-ADC based data acquisition system (DAQ) is presented. It has been tested using an alpha source and heavy ion reaction measurements at GSI's UNILAC accelerator facility. In addition, a novel analysis algorithm has been implemented thus increasing the sensitive area of the double-sided silicon strip detector (DSSD) in use.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Prototype readout electronics of a double-sided silicon strip detector for space exploration
    Wang, Li
    Cao, Zhe
    Sun, Wenrui
    Feng, Changqing
    Li, Chunjuan
    Xia, Li
    An, Qi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (11):
  • [32] OPERATIONAL EXPERIENCE WITH A LARGE DETECTOR SYSTEM USING SILICON STRIP DETECTORS WITH DOUBLE SIDED READOUT
    BATIGNANI, G
    BAUER, C
    BECKER, H
    BLOCHDEVAUX, B
    BOUDREAU, J
    BROWN, D
    BOSI, F
    BOSISIO, L
    CARPINELLI, M
    CARR, J
    CATTANEO, P
    CIOCCI, A
    COYLE, P
    DELLORSO, R
    DIETL, H
    DRINKARD, J
    FOCARDI, E
    FORTI, F
    GIORGI, M
    HANSLKOZANECKA, T
    HAUFF, D
    HOLL, P
    JACOBSEN, RG
    LANCON, E
    LAUBER, J
    LITKE, A
    LUTZ, G
    LUTJENS, G
    MANNELLI, E
    MANNER, W
    MATTISON, T
    MCNEIL, M
    MENARY, S
    MONETA, L
    MOSER, HG
    MOURS, B
    OSSA, R
    PARRINI, G
    PICCININI, S
    REDLINGER, G
    RIZZI, D
    RIZZO, G
    ROOS, L
    ROUSSEAU, D
    TAYLOR, G
    TONELLI, G
    TRIGGIANI, G
    SCHWARZ, AS
    SCHWEMLING, P
    SETTLES, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2): : 183 - 188
  • [33] Double-sided silicon strip detectors: new applications within genomics and proteomics
    Cekaite, L
    Hovig, E
    Hauge, HH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 68 - 72
  • [34] Efficiency of non-uniformly irradiated double-sided silicon strip detectors
    Dubbs, T
    Kashigin, S
    Kratzer, M
    Kroeger, W
    Pulliam, T
    Sadrozinski, HFW
    Schwab, M
    Spencer, E
    Wichmann, R
    Wilder, M
    Unno, Y
    Ohsugi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1142 - 1145
  • [35] Radiation hardness of the HERA-B double-sided silicon strip detectors
    Bauer, C
    Glebe, T
    Knöpfle, KT
    Pugatch, V
    Schwingenheuer, B
    Abt, I
    Dressel, M
    Masciocchi, S
    Perschke, T
    Schaller, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 116 - 120
  • [36] Efficiency of non-uniformly irradiated double-sided silicon strip detectors
    Dubbs, T
    Kashigin, S
    Kratzer, M
    Kroeger, W
    Pulliam, T
    Sadrozinski, HFW
    Schwab, M
    Spencer, E
    Wichmann, R
    Wilder, M
    Unno, Y
    Ohsugi, T
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 488 - 491
  • [37] Design Considerations for Double-Sided Silicon Strip Detectors Applicable to PET Imaging
    Studen, A.
    Clinthorne, N. H.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3076 - 3081
  • [38] Characterization and calibration of radiation-damaged double-sided silicon strip detectors
    Kaya, L.
    Vogt, A.
    Reiter, P.
    Birkenbach, B.
    Hirsch, R.
    Arnswald, K.
    Hess, H.
    Seidlitz, M.
    Steinbach, T.
    Warr, N.
    Wolf, K.
    Stahl, C.
    Pietralla, N.
    Limboeck, T.
    Meerholz, K.
    Lutter, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 855 : 109 - 117
  • [39] Characterization of a double-sided silicon strip detector autoradiography system
    Orbom, Anders
    Ahlstedt, Jonas
    Seren, Tom
    Auterinen, Iiro
    Kotiluoto, Petri
    Hauge, Havard
    Ostlund, Karl
    Olafsen, Tove
    Wu, Anna M.
    Dahlbom, Magnus
    Strand, Sven-Erik
    MEDICAL PHYSICS, 2015, 42 (02) : 575 - 584
  • [40] AN OPTICAL DECOUPLING SYSTEM FOR DOUBLE-SIDED SILICON MICROSTRIP DETECTORS
    ADRIANI, O
    AMBROSI, G
    CASTELLINI, G
    LANDI, G
    PASSALEVA, G
    NUCLEAR PHYSICS B, 1993, : 480 - 486