On-line duplex molecularly imprinted solid-phase extraction for analysis of low-abundant biomarkers in human serum by liquid chromatography-tandem mass spectrometry

被引:11
|
作者
McKitterick, Nicholas [1 ]
Bicak, Tugrul Cem [2 ]
Switnicka-Plak, A. Magdalena [2 ]
Cormack, A. G. Peter [2 ]
Reubsaet, Leon [1 ]
Halvorsen, Trine Gronhaug [1 ]
机构
[1] Univ Oslo, Sect Pharmaceut Chem, Dept Pharm, POB 1068 Blindern, N-0316 Oslo, Norway
[2] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Thomas Graham Bldg,295 Cathedral St, Glasgow G1 1XL, Lanark, Scotland
基金
欧盟地平线“2020”;
关键词
On-line SPE; Multiplexing; Molecularly imprinted polymers; LC-MS/MS; Low-abundant biomarkers; Targeted bottom-up proteomics; NEURON-SPECIFIC ENOLASE; POLYMERS; LUNG; QUANTIFICATION; SAMPLES; IMMUNOCAPTURE; DIGESTION; ENRICHMENT; ANTIBODIES; PROTEINS;
D O I
10.1016/j.chroma.2021.462490
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, a pair of molecularly imprinted polymers (MIPs) targeting distinct peptide targets were packed into trap columns and combined for automated duplex analysis of two low abundant small cell lung cancer biomarkers (neuron-specific enolase [NSE] and progastrin-releasing peptide [ProGRP]). Optimization of the on-line molecularly imprinted solid-phase extraction (MISPE) protocol ensured that the MIPs had the necessary affinity and selectivity towards their respective signature peptide targets - NLLGLIEAK (ProGRP) and ELPLYR (NSE) - in serum. Two duplex formats were evaluated: a physical mix-ture of the two MIPs (1:1 w/w ratio) inside a single trap column, and two separate MIP trap columns connected in series. Both duplex formats enabled the extraction of the peptides from serum. However, the trap columns in series gave superior extraction efficiency (85.8 +/- 3.8% and 49.1 +/- 6.7% for NLLGLIEAK and ELPLYR, respectively). The optimized protocol showed satisfactory intraday (RSD <23.4 %) and interday (RSD <14.6%) precision. Duplex analysis of NSE and ProGRP spiked into digested human serum was linear (R-2 >= 0.98) over the disease range (0.3-30 nM). The estimated limit of detection (LOD) and limit of quan-tification (LOQ) were 0.11 nM and 0.37 nM, respectively, for NSE, and 0.06 nM and 0.2 nM, respectively, for ProGRP. Both biomarkers were determined at clinically relevant levels. To the best of our knowledge, the present work is the first report of an automated MIP duplex biomarker analysis. It represents a proof of concept for clinically viable duplex analysis of low abundant biomarkers present in human serum or other biofluids. (C) 2021 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Determination of pesticide residues in wine by solid-phase extraction on-line combined with liquid chromatography tandem mass spectrometry
    Perez-Mayan, L.
    Ramil, M.
    Cela, R.
    Rodriguez, I.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 104
  • [42] Determination of palmatine in canine plasma by liquid chromatography-tandem mass spectrometry with solid-phase extraction
    Huang, Jian-ming
    Wang, Guo-quan
    Jin, Yu-e
    Shen, Teng
    Weng, Weiyu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 854 (1-2): : 279 - 285
  • [43] Tetrodotoxin poisoning evidenced by solid-phase extraction combining with liquid chromatography-tandem mass spectrometry
    Jen, Hsiao-Chin
    Lin, Shin-Jung
    Tsai, Yung-Hsiang
    Chen, Chun-Hsiang
    Lin, Zu-Chun
    Hwang, Deng-Fwu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (01): : 95 - 100
  • [44] Determination of alkylbenzene metabolites in groundwater by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Alumbaugh, RE
    Gieg, LM
    Field, JA
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1042 (1-2) : 89 - 97
  • [45] Determination of estrogens and estrogen mimics by solid-phase extraction with liquid chromatography-tandem mass spectrometry
    Li, Yejin
    Yang, Linyan
    Zhen, Huajun
    Chen, Xueming
    Sheng, Mei
    Li, Kai
    Xue, Weibo
    Zhao, Huihui
    Meng, Shujuan
    Cao, Guomin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1168
  • [46] A dummy molecularly imprinted solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry for selective determination of four pyridine carboxylic acid herbicides in milk
    Tan, Sijia
    Yu, Hailong
    He, Yahui
    Wang, Miao
    Liu, Guiqiao
    Hong, Sihui
    Yan, Feiyan
    Wang, Yanli
    Wang, MengQiang
    Li, Tengfei
    Wang, Jing
    Abd El-Aty, A. M.
    Haclmuftuoglu, Ahmet
    She, Yongxin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1108 : 65 - 72
  • [47] Solid-phase immunoextraction followed by liquid chromatography-tandem mass spectrometry for the selective determination of thyroxine in human serum
    Vallez-Gomis, Victor
    Benede, Juan L.
    Combes, Audrey
    Chisvert, Alberto
    Pichon, Valerie
    TALANTA, 2023, 265
  • [48] Charged derivatization and on-line solid phase extraction to measure extremely low cortisol and cortisone levels in human saliva with liquid chromatography-tandem mass spectrometry
    Magda, Balazs
    Dobi, Zoltan
    Meszaros, Katalin
    Szabo, Eva
    Marta, Zoltan
    Imre, Timea
    Szabo, Pal T.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 140 : 223 - 231
  • [49] On-line solid-phase extraction coupled to liquid chromatography tandem mass spectrometry optimized for the analysis of steroid hormones in urban wastewaters
    Fayad, Paul B.
    Prevost, Michele
    Sauve, Sebastien
    TALANTA, 2013, 115 : 349 - 360
  • [50] Analysis of a basic drug by on-line solid-phase extraction liquid chromatography/tandem mass spectrometry using a mixed mode sorbent
    Mallet, CR
    Lu, ZL
    Mazzeo, J
    Neue, U
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (08) : 805 - 813