On-line duplex molecularly imprinted solid-phase extraction for analysis of low-abundant biomarkers in human serum by liquid chromatography-tandem mass spectrometry

被引:11
|
作者
McKitterick, Nicholas [1 ]
Bicak, Tugrul Cem [2 ]
Switnicka-Plak, A. Magdalena [2 ]
Cormack, A. G. Peter [2 ]
Reubsaet, Leon [1 ]
Halvorsen, Trine Gronhaug [1 ]
机构
[1] Univ Oslo, Sect Pharmaceut Chem, Dept Pharm, POB 1068 Blindern, N-0316 Oslo, Norway
[2] Univ Strathclyde, Dept Pure & Appl Chem, WestCHEM, Thomas Graham Bldg,295 Cathedral St, Glasgow G1 1XL, Lanark, Scotland
基金
欧盟地平线“2020”;
关键词
On-line SPE; Multiplexing; Molecularly imprinted polymers; LC-MS/MS; Low-abundant biomarkers; Targeted bottom-up proteomics; NEURON-SPECIFIC ENOLASE; POLYMERS; LUNG; QUANTIFICATION; SAMPLES; IMMUNOCAPTURE; DIGESTION; ENRICHMENT; ANTIBODIES; PROTEINS;
D O I
10.1016/j.chroma.2021.462490
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present work, a pair of molecularly imprinted polymers (MIPs) targeting distinct peptide targets were packed into trap columns and combined for automated duplex analysis of two low abundant small cell lung cancer biomarkers (neuron-specific enolase [NSE] and progastrin-releasing peptide [ProGRP]). Optimization of the on-line molecularly imprinted solid-phase extraction (MISPE) protocol ensured that the MIPs had the necessary affinity and selectivity towards their respective signature peptide targets - NLLGLIEAK (ProGRP) and ELPLYR (NSE) - in serum. Two duplex formats were evaluated: a physical mix-ture of the two MIPs (1:1 w/w ratio) inside a single trap column, and two separate MIP trap columns connected in series. Both duplex formats enabled the extraction of the peptides from serum. However, the trap columns in series gave superior extraction efficiency (85.8 +/- 3.8% and 49.1 +/- 6.7% for NLLGLIEAK and ELPLYR, respectively). The optimized protocol showed satisfactory intraday (RSD <23.4 %) and interday (RSD <14.6%) precision. Duplex analysis of NSE and ProGRP spiked into digested human serum was linear (R-2 >= 0.98) over the disease range (0.3-30 nM). The estimated limit of detection (LOD) and limit of quan-tification (LOQ) were 0.11 nM and 0.37 nM, respectively, for NSE, and 0.06 nM and 0.2 nM, respectively, for ProGRP. Both biomarkers were determined at clinically relevant levels. To the best of our knowledge, the present work is the first report of an automated MIP duplex biomarker analysis. It represents a proof of concept for clinically viable duplex analysis of low abundant biomarkers present in human serum or other biofluids. (C) 2021 The Author(s). Published by Elsevier B.V.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Automated on-line solid-phase extraction coupled to liquid chromatography-tandem mass spectrometry for determination of lipophilic marine toxins in shellfish
    Regueiro, Jorge
    Rossignoli, Araceli E.
    Alvarez, Gonzalo
    Blanco, Juan
    FOOD CHEMISTRY, 2011, 129 (02) : 533 - 540
  • [22] Sesame oil determination by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Xinjing Dou
    Liangxiao Zhang
    Peiwu Li
    Huali Xie
    Huhu Lang
    Xiaomei Chen
    Li Yu
    Wen Zhang
    Qi Zhang
    Oil Crop Science, 2017, 2 (03) : 181 - 186
  • [23] Solid-phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry
    Huang, Jin-Feng
    Xian, Yan-Ping
    Li, Xiu-Ying
    Cai, Wei-Hong
    Li, He
    Lin, Sen-Yu
    He, Min-Heng
    Guo, Xin-Dong
    Modern Food Science and Technology, 2014, 30 (12) : 241 - 246
  • [24] Automated isotope dilution liquid chromatography-tandem mass spectrometry with on-line dilution and solid phase extraction for the measurement of cortisol in human serum sample
    Kawaguchi, Migaku
    Eyama, Sakae
    Takatsu, Akiko
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 96 : 220 - 223
  • [25] On-line solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry for the quantitative analysis of tacrolimus in whole blood hemolyzate
    Volker Neu
    Nathanaël Delmotte
    Uwe Kobold
    Thomas Dülffer
    Rupert Herrmann
    Herbert von der Eltz
    Christian G. Huber
    Analytical and Bioanalytical Chemistry, 2012, 404 : 863 - 874
  • [26] On-line solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry for the quantitative analysis of tacrolimus in whole blood hemolyzate
    Neu, Volker
    Delmotte, Nathanael
    Kobold, Uwe
    Duelffer, Thomas
    Herrmann, Rupert
    von der Eltz, Herbert
    Huber, Christian G.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (03) : 863 - 874
  • [27] Multiresidue trace analysis of pharmaceuticals, their human metabolites and transformation products by fully automated on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry
    Jesus Garcia-Galan, Maria
    Petrovic, Mira
    Rodriguez-Mozaz, Sara
    Barcelo, Damia
    TALANTA, 2016, 158 : 330 - 341
  • [28] Analysis of macrolide antibiotics in water by magnetic solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Ana Perez, Rosa
    Albero, Beatriz
    Ferriz, Macarena
    Luis Tadeo, Jose
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 79 - 85
  • [29] Analysis of molluscicide metaldehyde in vegetables by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Zhang, H. Y.
    Wang, C.
    Xu, P. J.
    Ma, Y. Q.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (08): : 1034 - 1040
  • [30] A fast method for analysing six perfluoroalkyl substances in human serum by solid-phase extraction on-line coupled to liquid chromatography tandem mass spectrometry
    Bartolome, Monica
    Gallego-Pico, Alejandrina
    Huetos, Olga
    Angel Lucena, Miguel
    Castano, Argelia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (08) : 2159 - 2170