共 50 条
Biodegradation of the endogenous residue of activated sludge in a membrane bioreactor with continuous or on-off aeration
被引:28
|作者:
Ramdani, Abdellah
[1
]
Dold, Peter
[2
]
Gadbois, Alain
[3
]
Deleris, Stephane
[4
]
Houweling, Dwight
[2
]
Comeau, Yves
[1
]
机构:
[1] Ecole Polytech, Dept Civil Geol & Min Engn, Stn Ctr Ville, Montreal, PQ H3C 3A7, Canada
[2] EnviroSim Associates Ltd, Hamilton, ON L8P 0A1, Canada
[3] John Meunier Inc, St Laurent, PQ H4S 2B3, Canada
[4] Tech Dept, F-94417 St Maurice, France
基金:
加拿大自然科学与工程研究理事会;
关键词:
Activated sludge;
Endogenous residue;
Biodegradation;
Membrane digestion unit;
Aerobic digestion;
Intermittent aeration;
Modelling;
WASTE-WATER TREATMENT;
SOLUBLE MICROBIAL PRODUCTS;
AEROBIC DIGESTION;
BIOMASS;
SUBSTANCES;
ACID;
D O I:
10.1016/j.watres.2012.01.008
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
The goal of this study was to determine the effect of a long sludge retention time on the biodegradation of the endogenous residue in membrane digestion units receiving a daily feed of sludge and operated under either aerobic or intermittently aerated (22 h off-2 h on) conditions. The mixed liquor for these experiments was generated in a 10.4 day sludge retention time membrane bioreactor fed with a synthetic and completely biodegradable influent with acetate as the sole carbon source. It had uniform characteristics and consisted of only two components, heterotrophic biomass X-H and endogenous residue X-E. Membrane digestion unit experiments were conducted for 80 days without any sludge wastage except for some sampling. The dynamic behaviour of generation and consumption of filtered organic digestion products was characterized in the membrane digestion unit systems using three pore filter sizes. Results from this investigation indicated that the colloidal matter with size between 0.04 mu m and 0.45 mu m was shown to contain a recalcitrant fraction possibly composed of polysaccharides bound to proteins which accumulated in the membrane digestion unit under both conditions. Modelling the membrane digestion unit results by considering a first-order decay of the endogenous residue allowed to determine values of the endogenous residue decay rate of 0.0065 and 0.0072 d(-1) under fully aerobic and intermittently aerated conditions, respectively. The effect of temperature on the endogenous decay rate was assessed for the intermittently aerated conditions in batch tests using thickened sludge from tests gave an endogenous decay rate constant of 0.0075 d(-1) at 20 degrees C and an Arrhenius temperature correction factor of 1.033. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2837 / 2850
页数:14
相关论文