Biodegradation of the endogenous residue of activated sludge in a membrane bioreactor with continuous or on-off aeration

被引:28
|
作者
Ramdani, Abdellah [1 ]
Dold, Peter [2 ]
Gadbois, Alain [3 ]
Deleris, Stephane [4 ]
Houweling, Dwight [2 ]
Comeau, Yves [1 ]
机构
[1] Ecole Polytech, Dept Civil Geol & Min Engn, Stn Ctr Ville, Montreal, PQ H3C 3A7, Canada
[2] EnviroSim Associates Ltd, Hamilton, ON L8P 0A1, Canada
[3] John Meunier Inc, St Laurent, PQ H4S 2B3, Canada
[4] Tech Dept, F-94417 St Maurice, France
基金
加拿大自然科学与工程研究理事会;
关键词
Activated sludge; Endogenous residue; Biodegradation; Membrane digestion unit; Aerobic digestion; Intermittent aeration; Modelling; WASTE-WATER TREATMENT; SOLUBLE MICROBIAL PRODUCTS; AEROBIC DIGESTION; BIOMASS; SUBSTANCES; ACID;
D O I
10.1016/j.watres.2012.01.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The goal of this study was to determine the effect of a long sludge retention time on the biodegradation of the endogenous residue in membrane digestion units receiving a daily feed of sludge and operated under either aerobic or intermittently aerated (22 h off-2 h on) conditions. The mixed liquor for these experiments was generated in a 10.4 day sludge retention time membrane bioreactor fed with a synthetic and completely biodegradable influent with acetate as the sole carbon source. It had uniform characteristics and consisted of only two components, heterotrophic biomass X-H and endogenous residue X-E. Membrane digestion unit experiments were conducted for 80 days without any sludge wastage except for some sampling. The dynamic behaviour of generation and consumption of filtered organic digestion products was characterized in the membrane digestion unit systems using three pore filter sizes. Results from this investigation indicated that the colloidal matter with size between 0.04 mu m and 0.45 mu m was shown to contain a recalcitrant fraction possibly composed of polysaccharides bound to proteins which accumulated in the membrane digestion unit under both conditions. Modelling the membrane digestion unit results by considering a first-order decay of the endogenous residue allowed to determine values of the endogenous residue decay rate of 0.0065 and 0.0072 d(-1) under fully aerobic and intermittently aerated conditions, respectively. The effect of temperature on the endogenous decay rate was assessed for the intermittently aerated conditions in batch tests using thickened sludge from tests gave an endogenous decay rate constant of 0.0075 d(-1) at 20 degrees C and an Arrhenius temperature correction factor of 1.033. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2837 / 2850
页数:14
相关论文
共 50 条
  • [21] IFAS Intermittent Aeration Membrane Bioreactor System: The Influence of Sludge Retention Time
    Mofatto, Paulo M. Bosco
    Cosenza, Alida
    Di Trapani, Daniele
    Mannina, Giorgio
    FRONTIERS IN MEMBRANE TECHNOLOGY, IWA-RMTC 2024, 2024, 525 : 67 - 72
  • [22] The effect of fine bubble aeration intensity on membrane bioreactor sludge characteristics and fouling
    De Temmerman, L. D
    Maere, T.
    Temmink, H.
    Zwijnenburg, A.
    Nopens, I.
    WATER RESEARCH, 2015, 76 : 99 - 109
  • [23] Osmotic membrane bioreactor for phenol biodegradation under continuous operation
    Praveen, Prashant
    Loh, Kai-Chee
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 305 : 115 - 122
  • [24] Sludge reduction via biodegradation of the endogenous residue (XE): experimental verification and modeling
    Fall, Cheikh
    Millan-Lagunas, Ericka L.
    Lopez-Vazquez, Carlos
    Maria Hooijmans, Christine
    Comeau, Yves
    WATER SCIENCE AND TECHNOLOGY, 2017, 75 (03) : 561 - 570
  • [25] Effect of biosurfactant on 2,4-dichlorophenol biodegradation in an activated sludge bioreactor
    Uysal, A
    Türkman, A
    PROCESS BIOCHEMISTRY, 2005, 40 (08) : 2745 - 2749
  • [26] Biodegradation of persistent polar pollutants in wastewater:: Comparison of an optimised lab-scale membrane bioreactor and activated sludge treatment
    Bernhard, Marco
    Mueller, Jutta
    Knepper, Thomas R.
    WATER RESEARCH, 2006, 40 (18) : 3419 - 3428
  • [27] Study of the influence of the electrocoagulation unit on activated sludge in membrane bioreactor
    Zhang, Haifeng
    Gao, Zhongyu
    Zhang, Lanhe
    MECHATRONICS ENGINEERING, COMPUTING AND INFORMATION TECHNOLOGY, 2014, 556-562 : 1870 - +
  • [28] Activities of Activated Sludge Affected by Pharmaceutical Wastewater in a Membrane Bioreactor
    Ding Yuanhong
    Wang Qing
    Ren Hongqiang
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 1426 - 1431
  • [29] Contribution of various constituents of activated sludge to membrane bioreactor fouling
    Defrance, L
    Jaffrin, MY
    Gupta, B
    Paullier, P
    Geaugey, V
    BIORESOURCE TECHNOLOGY, 2000, 73 (02) : 105 - 112
  • [30] Effect of components in activated sludge liquor on membrane fouling in a submerged membrane bioreactor
    Yu Shui-li
    Zhao Fang-bo
    Zhang Xiao-hui
    Jing Guo-lin
    Zhen Xiang-hua
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2006, 18 (05) : 897 - 902