Resonance measurement of capacitance current in ineffectively earthed power systems

被引:0
|
作者
Yi, W. T. [1 ]
Zeng, X. J. [1 ]
Choi, S. S. [2 ]
Liu, Z. L. [1 ]
机构
[1] Changsha Univ Sci & Technol, Sch Elect & Info Engn, Changsha 410077, Hunan, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
关键词
capacitance current; distribution system; grounding capacitance; grounding fault protection; voltage transformer; resonance measurement;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Capacitance current is an important parameter for single phase ground fault protection and control in ineffectively earthed power systems. A novel method for the capacitance current measurement is presented in the paper. An adjustable reactor is in series connection with the open-delta side of a zero sequence voltage transformer. System resonance frequency is sought by injecting a current signal with variable frequency. By changing the reactor inductance value, another resonance frequency can also be sought The ground capacitance and ground capacitance current can thus be calculated using the two resonance frequencies for the power systems. Experimental work shows that the proposed method has produced results of high precision in real-time, without the need to interrupt power supply.
引用
收藏
页码:1182 / +
页数:2
相关论文
共 50 条
  • [1] A novel method of measuring capacitance current for ineffectively earthed power systems
    Xu, Y.
    Zeng, X. J.
    Choi, S. S.
    Liu, Z. L.
    TENCON 2007 - 2007 IEEE REGION 10 CONFERENCE, VOLS 1-3, 2007, : 1151 - +
  • [2] A Novel Measurement Device of Capacitive Current for Ineffectively Earthed Distribution Systems
    Liu Zhanglei
    Zeng Xiangjun
    Jin Wangyi
    Yi Wentao
    Xu Yao
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 1682 - 1685
  • [3] Grounding Fault Protection with Phase Current Difference for Ineffectively Earthed Power Systems
    Wang Yuanyuan
    Zeng Xiangjun
    Su Sheng
    CONFERENCE RECORD OF THE 2006 IEEE INDUSTRY APPLICATIONS CONFERENCE, FORTY-FIRST IAS ANNUAL MEETING, VOL 1-5, 2006, : 2645 - 2650
  • [4] Ground fault protection scheme using leakage current in ineffectively earthed power systems
    Yuanyuan, Wang
    Xiangjun, Zeng
    Choi, S. S.
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 488 - +
  • [5] Ground fault protection for ineffectively earthed power systems
    Zeng, XJ
    Guo, ZG
    Su, S
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1650 - 1654
  • [6] Grounding fault protection with sampling value difference in ineffectively earthed power systems
    Wang Yuanyuan
    Zeng Xiangjun
    Ma Hongjiang
    Xia Yunfeng
    Xu Yao
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2060 - +
  • [7] Grounding fault protection based on fault resistance measurement for ineffectively earthed distribution systems
    School of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha 410076, China
    不详
    Gaodianya Jishu, 2007, 1 (26-30): : 26 - 30
  • [8] A Novel Single Phase Grounding Fault Protection Scheme Without Threshold Setting for Neutral Ineffectively Earthed Power Systems
    Zeng, Xiangjun
    Yu, Kun
    Wang, Yuanyuan
    Xu, Yao
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2016, 2 (03): : 73 - 81
  • [9] Grounding Faulted Feeder Detection Methods Applied in Chinese Ineffectively Earthed Distribution Systems
    Zeng Xiangjun
    Xia Yunfeng
    Ma Hongjiang
    Wang Yuanyuan
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 1348 - 1352
  • [10] A novel technique for measuring grounding capacitance and grounding fault resistance in ineffectively grounded power system
    Zeng, XJ
    Yin, XG
    Zhang, Z
    Chen, DS
    Yu, YY
    INTERNATIONAL CONFERENCE ON SENSORS AND CONTROL TECHNIQUES (ICSC 2000), 2000, 4077 : 324 - 327