Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated

被引:6
|
作者
Dashtdar, Masoud [1 ]
Sarada, K. [2 ]
Hosseinimoghadam, Seyed Mohammad Sadegh [1 ]
Kalyan, C. H. Naga Sai [3 ]
Venkateswarlu, A. N. [4 ]
Goud, B. Srikanth [5 ]
Reddy, C. H. Rami [6 ]
Belkhier, Youcef [7 ]
Bajaj, Mohit [8 ]
Reddy, B. Nagi [9 ]
机构
[1] Islamic Azad Univ, Elect Engn Dept, Bushehr Branch, Bushehr, Iran
[2] KLEF Deemed Univ, Dept Elect & Elect Engn, Guntur 522502, Andhra Pradesh, India
[3] VasireddyVenkatadri Inst Technol, Dept Elect & Elect Engn, Guntur 522508, Andhra Pradesh, India
[4] Vignans Lara Inst Technol & Sci, Dept Elect & Elect Engn, Guntur 522213, Andhra Pradesh, India
[5] Anurag Coll Engn, Dept Elect & Elect Engn, Ghatkesar 501301, Telangana, India
[6] Malla Reddy Engn Coll A, Dept Elect & Elect Engn, Maisammaguda 500100, Telangana, India
[7] Czech Tech Univ, Fac Elect Engn, Dept Comp Sci, Karlovo Namesti 13, Prague 12135 2, Czech Republic
[8] Natl Inst Technol, Dept Elect & Elect Engn, Delhi 110040, India
[9] Vignana Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad, India
关键词
Fault location; Distribution network; Histogram analysis; Convolution; Current and voltage modulated; TRANSMISSION-LINES; CLASSIFICATION;
D O I
10.1007/s42835-022-01079-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the discussion of fault location due to the existence of multiple branches in the distribution network, different locations are obtained and this shows the importance of detecting the faulted section in the distribution network. In this paper, the new idea of modulating the current and three-phase voltage of the line's beginning and histogram analysis has been used for fault location in the power network. First, threephases of current and voltage of the line's beginning are converted separately through convolution into a modulated current signal and a voltage signal, respectively. Then by dividing the density ratio of the modulated voltage by the modulated current, the distance to fault location can be estimated; but there is the possibility of obtaining several fault locations in the distribution network. In the following, the faulted section can be estimated through a histogram analysis of the modulated voltage. Simulation results show that by modulating the three-phase voltage, there is a possibility to eliminate the effects of fault resistance, fault occurrence angle, fault type on the algorithm's accuracy. In the end, the suggested algorithm was implemented on a 735 kV transmission network and an IEEE-15bus distribution network whose results demonstrate the appropriate accuracy of the suggested algorithm.
引用
收藏
页码:2631 / 2647
页数:17
相关论文
共 50 条
  • [41] Fault Identification and Location of Active Distribution Network Based on SVM Classification of Voltage Data
    Liu K.
    Dong W.
    Xiao S.
    Wei J.
    Zhao W.
    Dianwang Jishu/Power System Technology, 2021, 45 (06): : 2369 - 2379
  • [42] Three-phase voltage stability analysis in an integrated transmission-distribution network
    Banejad, Mahdi
    Kazeminejad, Mohammad
    Hosseinzadeh, Nasser
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 208
  • [43] Contact-Free Three-Phase Line Voltage Stabilizer for a Three-Wire Power Network
    A. I. Nosov
    E. G. Garbuz
    S. A. Vaganov
    Glass and Ceramics, 2005, 62 : 113 - 116
  • [44] Contact-free three-phase line voltage stabilizer for a three-wire power network
    Nosov, AI
    Garbuz, EG
    Vaganov, SA
    GLASS AND CERAMICS, 2005, 62 (3-4) : 113 - 116
  • [45] Voltage Stability Analysis in Unbalanced Three-phase Power Systems with Complementarity Constraints
    Carpinelli, Guido
    Caramia, Pierluigi
    Varilone, Pietro
    2013 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2013, : 12 - 17
  • [46] Line fault test of model power system with three-phase superconducting fault current-limiting reactors
    Kado, Hiroyuki
    Uriu, Yoshihisa
    Ishigooka, Takeshi
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1992, 112 (04): : 85 - 90
  • [47] Static Reactive Power Compensator Design, Based on Three-Phase Voltage Converter
    Ayala-Chauvin, Manuel
    Kavrakov, Bahodurjon S.
    Buele, Jorge
    Varela-Aldas, Jose
    ENERGIES, 2021, 14 (08)
  • [48] Bearing fault identification of three-phase induction motors bases on two current sensor strategy
    Tiago Drummond Lopes
    Alessandro Goedtel
    Rodrigo Henrique Cunha Palácios
    Wagner Fontes Godoy
    Roberto Molina de Souza
    Soft Computing, 2017, 21 : 6673 - 6685
  • [49] Bearing fault identification of three-phase induction motors bases on two current sensor strategy
    Lopes, Tiago Drummond
    Goedtel, Alessandro
    Cunha Palacios, Rodrigo Henrique
    Godoy, Wagner Fontes
    de Souza, Roberto Molina
    SOFT COMPUTING, 2017, 21 (22) : 6673 - 6685
  • [50] Power loss analysis of single and three phase fault current limiters
    Haque, M. Tarafdar
    Abapour, Mehdi
    WSEAS Transactions on Systems, 2006, 5 (05): : 1208 - 1213