Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated

被引:6
|
作者
Dashtdar, Masoud [1 ]
Sarada, K. [2 ]
Hosseinimoghadam, Seyed Mohammad Sadegh [1 ]
Kalyan, C. H. Naga Sai [3 ]
Venkateswarlu, A. N. [4 ]
Goud, B. Srikanth [5 ]
Reddy, C. H. Rami [6 ]
Belkhier, Youcef [7 ]
Bajaj, Mohit [8 ]
Reddy, B. Nagi [9 ]
机构
[1] Islamic Azad Univ, Elect Engn Dept, Bushehr Branch, Bushehr, Iran
[2] KLEF Deemed Univ, Dept Elect & Elect Engn, Guntur 522502, Andhra Pradesh, India
[3] VasireddyVenkatadri Inst Technol, Dept Elect & Elect Engn, Guntur 522508, Andhra Pradesh, India
[4] Vignans Lara Inst Technol & Sci, Dept Elect & Elect Engn, Guntur 522213, Andhra Pradesh, India
[5] Anurag Coll Engn, Dept Elect & Elect Engn, Ghatkesar 501301, Telangana, India
[6] Malla Reddy Engn Coll A, Dept Elect & Elect Engn, Maisammaguda 500100, Telangana, India
[7] Czech Tech Univ, Fac Elect Engn, Dept Comp Sci, Karlovo Namesti 13, Prague 12135 2, Czech Republic
[8] Natl Inst Technol, Dept Elect & Elect Engn, Delhi 110040, India
[9] Vignana Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad, India
关键词
Fault location; Distribution network; Histogram analysis; Convolution; Current and voltage modulated; TRANSMISSION-LINES; CLASSIFICATION;
D O I
10.1007/s42835-022-01079-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the discussion of fault location due to the existence of multiple branches in the distribution network, different locations are obtained and this shows the importance of detecting the faulted section in the distribution network. In this paper, the new idea of modulating the current and three-phase voltage of the line's beginning and histogram analysis has been used for fault location in the power network. First, threephases of current and voltage of the line's beginning are converted separately through convolution into a modulated current signal and a voltage signal, respectively. Then by dividing the density ratio of the modulated voltage by the modulated current, the distance to fault location can be estimated; but there is the possibility of obtaining several fault locations in the distribution network. In the following, the faulted section can be estimated through a histogram analysis of the modulated voltage. Simulation results show that by modulating the three-phase voltage, there is a possibility to eliminate the effects of fault resistance, fault occurrence angle, fault type on the algorithm's accuracy. In the end, the suggested algorithm was implemented on a 735 kV transmission network and an IEEE-15bus distribution network whose results demonstrate the appropriate accuracy of the suggested algorithm.
引用
收藏
页码:2631 / 2647
页数:17
相关论文
共 50 条
  • [31] Induced Voltages Ratio-Based Algorithm for Fault Detection, and Faulted Phase and Winding Identification of a Three-Winding Power Transformer
    Lee, Byung Eun
    Park, Jung-Wook
    Crossley, Peter A.
    Kang, Yong Cheol
    ENERGIES, 2014, 7 (09) : 6031 - 6049
  • [32] Fault Diagnosis of Three-phase Four-wire Active Power Filter Based on Current Feature Extraction
    Zhong, Ningfan
    Zhu, Mingxiu
    Huang, Qing
    2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, : 2998 - 3002
  • [33] Fault current limiter based on self-turn-off devices for three-phase ungrounded power systems
    Nanjing Normal University, Nanjing 210042, China
    不详
    不详
    Diangong Jishu Xuebao, 2007, 5 (64-70):
  • [34] Transient analysis of three-phase transmission lines with initial voltage and current distributions
    Natl Taiwan Ocean Univ, Keelung, Taiwan
    Electr Power Syst Res, 3 (177-186):
  • [35] Transient analysis of three-phase transmission lines with initial voltage and current distributions
    Li, JC
    ELECTRIC POWER SYSTEMS RESEARCH, 1995, 35 (03) : 177 - 186
  • [36] Analysis of Three-Phase Power Transformer Inrush Current Magnetic Field
    Li, Hongkui
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 : 1719 - 1723
  • [37] A method for three-phase power flow in a medium-voltage ungrounded distribution network
    Zhang Y.
    Lin J.
    Li C.
    Shao Z.
    Lan T.
    Chen S.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (17): : 26 - 36
  • [38] A Novel PLL Based on Reference Current for Three-Phase Power Systems
    Jing, Guanjun
    Yuan, Qiping
    Miao, Yinping
    Chen, Zhihong
    Yang, Xiaoping
    2016 IEEE INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING (DSP), 2016, : 164 - 167
  • [39] Three-Phase Inverter Fault Diagnosis Based on an Improved Deep Residual Network
    Fu, Yanfang
    Ji, Yu
    Meng, Gong
    Chen, Wei
    Bai, Xiaojun
    ELECTRONICS, 2023, 12 (16)
  • [40] Fault section location method for single-phase grounding fault in distribution network based on ESMD
    Yin Z.
    Sun G.
    Ding J.
    Lü F.
    Yuan H.
    Wei Z.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (06): : 173 - 178and191