Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated

被引:6
|
作者
Dashtdar, Masoud [1 ]
Sarada, K. [2 ]
Hosseinimoghadam, Seyed Mohammad Sadegh [1 ]
Kalyan, C. H. Naga Sai [3 ]
Venkateswarlu, A. N. [4 ]
Goud, B. Srikanth [5 ]
Reddy, C. H. Rami [6 ]
Belkhier, Youcef [7 ]
Bajaj, Mohit [8 ]
Reddy, B. Nagi [9 ]
机构
[1] Islamic Azad Univ, Elect Engn Dept, Bushehr Branch, Bushehr, Iran
[2] KLEF Deemed Univ, Dept Elect & Elect Engn, Guntur 522502, Andhra Pradesh, India
[3] VasireddyVenkatadri Inst Technol, Dept Elect & Elect Engn, Guntur 522508, Andhra Pradesh, India
[4] Vignans Lara Inst Technol & Sci, Dept Elect & Elect Engn, Guntur 522213, Andhra Pradesh, India
[5] Anurag Coll Engn, Dept Elect & Elect Engn, Ghatkesar 501301, Telangana, India
[6] Malla Reddy Engn Coll A, Dept Elect & Elect Engn, Maisammaguda 500100, Telangana, India
[7] Czech Tech Univ, Fac Elect Engn, Dept Comp Sci, Karlovo Namesti 13, Prague 12135 2, Czech Republic
[8] Natl Inst Technol, Dept Elect & Elect Engn, Delhi 110040, India
[9] Vignana Bharathi Inst Technol, Dept Elect & Elect Engn, Hyderabad, India
关键词
Fault location; Distribution network; Histogram analysis; Convolution; Current and voltage modulated; TRANSMISSION-LINES; CLASSIFICATION;
D O I
10.1007/s42835-022-01079-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the discussion of fault location due to the existence of multiple branches in the distribution network, different locations are obtained and this shows the importance of detecting the faulted section in the distribution network. In this paper, the new idea of modulating the current and three-phase voltage of the line's beginning and histogram analysis has been used for fault location in the power network. First, threephases of current and voltage of the line's beginning are converted separately through convolution into a modulated current signal and a voltage signal, respectively. Then by dividing the density ratio of the modulated voltage by the modulated current, the distance to fault location can be estimated; but there is the possibility of obtaining several fault locations in the distribution network. In the following, the faulted section can be estimated through a histogram analysis of the modulated voltage. Simulation results show that by modulating the three-phase voltage, there is a possibility to eliminate the effects of fault resistance, fault occurrence angle, fault type on the algorithm's accuracy. In the end, the suggested algorithm was implemented on a 735 kV transmission network and an IEEE-15bus distribution network whose results demonstrate the appropriate accuracy of the suggested algorithm.
引用
收藏
页码:2631 / 2647
页数:17
相关论文
共 50 条
  • [1] Faulted Section Identification and Fault Location in Power Network Based on Histogram Analysis of Three-phase Current and Voltage Modulated
    Masoud Dashtdar
    K. Sarada
    Seyed Mohammad Sadegh Hosseinimoghadam
    C. H. Naga Sai Kalyan
    A. N. Venkateswarlu
    B. Srikanth Goud
    C. H. Rami Reddy
    Youcef Belkhier
    Mohit Bajaj
    B. Nagi Reddy
    Journal of Electrical Engineering & Technology, 2022, 17 : 2631 - 2647
  • [2] On the analysis of voltage and current transients in three-phase power systems
    Bollen, Math H. J.
    Gu, Irene Yu-Hua
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (02) : 1194 - 1201
  • [3] A Fault Phase Selection for Distribution Network Based on Correlation Coefficient of Three-phase Transient Voltage
    Han, Xiaoyan
    Ren, Qin
    Shu, Qin
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 765 - 771
  • [4] Fault Current & Fault voltage Analysis of Power Distribution Network
    Kadam, S. R.
    Kale, R. U.
    Deokar, T. V.
    Pawar, P. B.
    2018 3RD INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2018,
  • [5] An algorithm for estimating fault location in an unbalanced three-phase power system
    Soliman, SA
    Abdel-Rahman, MH
    Al-Attar, E
    El-Hawary, ME
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (07) : 515 - 520
  • [6] Study on Section Location of Medium Voltage Distribution Network Based on Fifth Harmonic Current Fault Component
    Gao, Shuping
    Lin, Zihao
    PROCEEDINGS OF 2018 IEEE 3RD ADVANCED INFORMATION TECHNOLOGY, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (IAEAC 2018), 2018, : 1326 - 1331
  • [7] Analysis of Current Distortion of Three-Phase Voltage Source Rectifiers and its Application in Fault Diagnosis
    Sui, Chunsong
    He, Yigang
    Chen, Mingyun
    IEEE ACCESS, 2020, 8 : 4065 - 4075
  • [8] A Fault Diagnosis Method in Three-Phase Voltage Inverters Based on the Normalized Current Trajectory Centroid
    Han, Sumin
    Shang, Zhihao
    Guo, Yu
    Jia, Xinjiao
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2024, 19 (07) : 4421 - 4434
  • [9] A direct three-phase circuit analysis-based fault location for line-to-line fault
    Choi, Myeon-Song
    Lee, Seung-Jae
    Lim, Seong-Il
    Lee, Duck-Su
    Yang, Xia
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2541 - 2547
  • [10] Power system fault diagnosis based on Bayesian network and fault section location
    He, Xiao-Fei
    Tong, Xiao-Yang
    Zhou, Shu
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (12): : 29 - 34