CMOS read-out IC with op-amp pixel amplifier for infrared focal plane arrays

被引:0
|
作者
Niewiadomski, JJ
Carlson, BS
机构
关键词
D O I
10.1109/ASIC.1997.616980
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The design and prototype of a read-out integrated circuit for an uncooled infrared focal plane array are described in this paper. The device is designed to interface to a pyroelectric infrared detector array of size 320 x 240. The read-out IC presented here achieves better performance and uniformity compared to existing approaches by implementing a single stage CMOS op-amp within each pixel of the detector array. The prototype devices exhibit fixed pattern noise less than 5mv (0.5% of full scale) without correction. The pixel amplifier exhibits less than 0.6% maximum (0.5% average) relative gain error with less than 0.2% gain variation over the 1V input range.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 50 条
  • [41] VO2-based microbolometer uncooled infrared focal plane arrays with CMOS readout integrated circuit
    Chen, XQ
    Yi, XJ
    OPTOELECTRONIC MATERIALS AND DEVICES FOR OPTICAL COMMUNICATIONS, 2005, 6020
  • [42] 640 x 512 pixel long-wavelength infrared narrowband, multiband, and broadband QWIP focal plane arrays
    Gunapala, SD
    Bandara, SV
    Liu, JK
    Rafol, SB
    Mumolo, JM
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2003, 50 (12) : 2353 - 2360
  • [43] New Read-out electronics concept for visual and infrared detector arrays in astronomical instrumentation - art. no. 70145S
    Wagner, Karl
    Mall, Ulrich
    Ramos, Jose
    Klein, Ralf
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY II, PTS 1-4, 2008, 7014 : S145 - S145
  • [44] 1.2V Constant-gm Rail-to-Rail CMOS Op-Amp Input Stage with New Overlapped Transition Regions Technique for ECG Amplifier
    Lee, Boram
    Higman, Ted
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3455 - 3458
  • [45] New thermally isolated pixel structure for high-resolution (640 X 480) uncooled infrared focal plane arrays
    Tohyama, S
    Miyoshi, M
    Kurashina, S
    Ito, N
    Sasaki, T
    Ajisawa, A
    Tanaka, Y
    Kawahara, A
    Iida, K
    Oda, N
    OPTICAL ENGINEERING, 2006, 45 (01)
  • [46] Thermal imaging camera with linear Pb1-xSnxSe-on-Si infrared sensor array and combined JFET/CMOS read-out electronics
    Masek, J
    Fach, A
    John, J
    Muller, P
    Paglino, C
    Zogg, H
    Buttler, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 496 - 500
  • [47] Small-pixel long wavelength infrared focal plane arrays based on InAs/GaSb Type-II superlattice
    Han, Xi
    Jiang, Dongwei
    Wang, Guowei
    Hao, Hongyue
    Sun, Yaoyao
    Jiang, Zhi
    Lv, Yuexi
    Guo, Chunyan
    Xu, Yingqiang
    Niu, Zhichuan
    INFRARED PHYSICS & TECHNOLOGY, 2018, 89 : 35 - 40
  • [48] Thermal imaging camera with linear Pb1-xSnxSe-on-Si infrared sensor array and combined JFET/CMOS read-out electronics
    Masek, J.
    Fach, A.
    John, J.
    Muller, P.
    Paglino, C.
    Zogg, H.
    Buttler, W.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 377 (2-3): : 496 - 500
  • [49] 1024 x 1024 pixel mid-wavelength and long-wavelength infrared QWIP focal plane arrays for imaging applications
    Gunapala, SD
    Bandara, SV
    Liu, JK
    Hill, CJ
    Rafol, SB
    Mumolo, JM
    Trinh, JT
    Tidrow, MZ
    Le Van, PD
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2005, 20 (05) : 473 - 480
  • [50] A 60ns 500 x 12 0.35μm CMOS low-power scanning read-out IC for cryogenic infra-red sensors
    Serra-Graells, F
    Misischi, B
    Casanueva, E
    Méndez, C
    Terés, L
    2005 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), VOLS 1-6, CONFERENCE PROCEEDINGS, 2005, : 1742 - 1745