Diagnostic reference levels (DRLs) for routine X-ray examinations in Lorestan province, Iran

被引:0
|
作者
Gholami, M. [1 ]
Maziar, A. [2 ]
Khosravi, H. R. [3 ]
Ebrahimzadeh, F. [4 ]
Mayahi, S. [1 ]
机构
[1] Lorestan Univ Med Sci, Fac Allied Med Sci, Dept Med Phys & Radiat Sci, Khorramabad, Iran
[2] Isfahan Univ Med Sci, Fac Med, Dept Med Phys & Med Engn, Esfahan, Iran
[3] Atom Energy Org Iran, Tehran, Iran
[4] Lorestan Univ Med Sci, Fac Hlth & Nutr, Dept Biostat, Khorramabad, Iran
来源
关键词
Diagnostic radiology; ESAK; patient dose; Lorestan province; quality control; DOSE MEASUREMENTS; ENTRANCE SURFACE; EXPOSURES; BRAZIL; CHEST; UK;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. Firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. Secondly estimates of the absorbed dose to tissue and organs in the patients. Material and Methods: A total of 2382 patients were studied to calculate the Entrance Surface Air Kerma (ESAK) following seven radiographic examinations including: chest (PA, Lat), lumbar spines (AP, Lat), pelvis (AP), abdomen (AP), skull (PA, Lat), thoracic spine (AP, Lat) and cervical spines (AP, Lat). The ESAKs values were measured according to x- ray tube output, optimized exposure parameters and body thickness (tp) for each technique. Results: The parameters such as, 1st quartile, mean, median, 3rd quartile, minimum, maximum and standard deviation of each ESAK values are reported and compared to NRPB guide levels. The results showed that the ESAKs values in the lumbar spines and chest X-ray examinations were 30% above the guide levels. However, for the pelvis (AP), skull (PA) and abdomen (AP) examinations, these values were below than those reported by the NRPB. Conclusion: Periodic quality control and monitoring the technical performance of radiographers might effectively improve the image quality and eventually reducing the dose received by patients.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [1] ESTIMATION OF ADULT PATIENT DOSES FOR CHEST X-RAY EXAMINATIONS AND COMPARISON WITH DIAGNOSTIC REFERENCE LEVELS (DRLS)
    Mor, H. Bas
    Altinsoy, N.
    Soyler, I.
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 377 - 385
  • [2] Doses to patients in some routine diagnostic X-ray examinations in Iran: proposed the first Iranian diagnostic reference levels
    Asadinezhad, Mohsen
    Bahreyni Toossi, Mohammad Taghi
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (04) : 409 - 414
  • [3] Diagnostic reference levels for X-ray examinations
    Veit, R.
    Guggenberger, R.
    Nosske, D.
    Brix, G.
    RADIOLOGE, 2010, 50 (10): : 907 - +
  • [4] Local Diagnostic Reference Levels (LDRLs) for routine X-ray examinations in Morocco
    Talbi, M.
    Tahiri, Z.
    Eddaoui, K.
    El Mansouri, M.
    Nhila, O.
    Benmessaoud, M.
    Ait Ouaggou, I.
    Chakir, E.
    Sebihi, R.
    Khalis, M.
    RADIOPROTECTION, 2022, 57 (02) : 149 - 155
  • [5] ESTIMATION OF SKIN ENTRANCE DOSES (SEDs) FOR COMMON MEDICAL X-RAY DIAGNOSTIC EXAMINATIONS IN INDIA AND PROPOSED DIAGNOSTIC REFERENCE LEVELS (DRLs)
    Sonawane, A. U.
    Shirva, V. K.
    Pradhan, A. S.
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (02) : 129 - 136
  • [6] Local diagnostic reference levels for some common diagnostic X-ray examinations in Tehran county of Iran
    Toosi, Mohammad Taghi Bahreyni
    Asadinezhad, Mohsen
    RADIATION PROTECTION DOSIMETRY, 2007, 124 (02) : 137 - 144
  • [7] Local diagnostic reference levels in standard X-ray examinations
    Compagnone, G
    Pagan, L
    Bergamini, C
    RADIATION PROTECTION DOSIMETRY, 2005, 113 (01) : 54 - 63
  • [8] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [9] Consideration of diagnostic reference levels for pediatric chest X-ray examinations
    Asada, Yasuki
    Ichikawa, Takuma
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2019, 12 (04) : 382 - 387
  • [10] SUGGESTED DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC X-RAY EXAMINATIONS IN INDIA
    Sonawane, A. U.
    Kumar, J. V. K. Sunil
    Singh, Meghraj
    Pradhan, A. S.
    RADIATION PROTECTION DOSIMETRY, 2011, 147 (03) : 423 - 428