In-situ analysis of Pb isotope ratios using laser ablation MC-ICP-MS:: Controls on precision and accuracy and comparison between Faraday cup and ion counting systems

被引:47
|
作者
Kent, Adam J. R. [1 ]
机构
[1] Oregon State Univ, Dept Geosci, Corvallis, OR 97331 USA
关键词
D O I
10.1039/b801046c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This contribution compares in-situ laser ablation multicollector ICP-MS ( LA-MC-ICP-MS) measurements of Pb isotope composition using parallel Faraday cup and ion counter detector array to those made using solely Faraday cups. In the former configuration ion counting is used for the low abundance isotope (204)Pb as well as (200)Hg and (202)Hg isotopes required for correction of isobaric interference of (204)Hg. Accurate measurement of the differences in gain between ion counters and Faraday cups, required for determination of (208)Pb/(204)Pb, (207)Pb/(204)Pb and (206)Pb/(204)Pb ratios using ion counting, can be made by analysis of standard glasses to within +/- 0.3% (2s). For analyses made using Faraday cups or combined Faraday cup and ion counting detector arrays mass bias is effectively controlled by external normalization to (208)Pb/(206)Pb ratios measured in the same standard glasses. Provided that He sweep gas flow rates are kept constant and that adequate time is allowed for stabilization after changes in He flow, mass bias can be controlled to within +/- 0.05% ( 2s). The precision of measurements of Pb isotope ratios is strongly dependent on ion beam intensities. Internal precision of <= 0.02% (2se) on (208)Pb/(206)Pb and (207)Pb/(206)Pb ratios requires Sigma Pb ion beam intensity of > similar to 30-50 mV. At beam intensities < 100 mV Sigma Pb measurement of (208)Pb/(204)Pb, (207)Pb/(204)Pb and (206)Pb/(204)Pb ratios also benefit significantly from the use of ion counting to measure (204)Pb intensity, with an overall improvement of 1-2 orders of magnitude in internal standard error. However, the additional uncertainty associated with calibration of the Faraday cup-ion counter relative gain suggest that use of Faraday cup to measure (204)Pb is most appropriate at signal intensities > similar to 200 mV, equivalent to similar to 100 000 counts per second (cps) (204)Pb. Correction for (204)Hg interference does not substantially contribute to uncertainty as long as (204)Hg comprises less than similar to 20% of the total 204 ion beam.
引用
收藏
页码:968 / 975
页数:8
相关论文
共 35 条
  • [31] In-run measuring 177Hf16O/177Hf as a routine technique for in-situ Hf isotopic compositions analysis in zirconium-bearing minerals by laser ablation MC-ICP-MS
    Huang, Chao
    Yang, Yueheng
    Wang, Hao
    Xie, Liewen
    Wu, Shitou
    Xu, Lei
    Yang, Jinhui
    Wu, Fuyuan
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 194
  • [32] The combined measurement of 87Sr/86Sr isotope ratios and 88Sr/85Rb elemental ratios using laser ablation MC-ICP-MS and its application for food provenance studies: the case for Asturian beans
    Reguera-Galan, Aida
    Moldovan, Mariella
    Ignacio Garcia Alonso, J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) : 867 - 875
  • [34] A precise and accurate analytical method for determination of osmium isotope ratios at the 1-15 pg level by using a MC-ICP-MS equipped with sparging introduction and high-sensitivity discrete dynode-type ion-counting detectors
    Ohta, Junichiro
    Nozaki, Tatsuo
    Sato, Honami
    Ashida, Kana
    Kato, Yasuhiro
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (08) : 1600 - 1610
  • [35] In-situ precise isotopic analysis of tungsten using laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) with time resolved data acquisition
    Hirata, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (03) : 204 - 210