In-situ analysis of Pb isotope ratios using laser ablation MC-ICP-MS:: Controls on precision and accuracy and comparison between Faraday cup and ion counting systems

被引:47
|
作者
Kent, Adam J. R. [1 ]
机构
[1] Oregon State Univ, Dept Geosci, Corvallis, OR 97331 USA
关键词
D O I
10.1039/b801046c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This contribution compares in-situ laser ablation multicollector ICP-MS ( LA-MC-ICP-MS) measurements of Pb isotope composition using parallel Faraday cup and ion counter detector array to those made using solely Faraday cups. In the former configuration ion counting is used for the low abundance isotope (204)Pb as well as (200)Hg and (202)Hg isotopes required for correction of isobaric interference of (204)Hg. Accurate measurement of the differences in gain between ion counters and Faraday cups, required for determination of (208)Pb/(204)Pb, (207)Pb/(204)Pb and (206)Pb/(204)Pb ratios using ion counting, can be made by analysis of standard glasses to within +/- 0.3% (2s). For analyses made using Faraday cups or combined Faraday cup and ion counting detector arrays mass bias is effectively controlled by external normalization to (208)Pb/(206)Pb ratios measured in the same standard glasses. Provided that He sweep gas flow rates are kept constant and that adequate time is allowed for stabilization after changes in He flow, mass bias can be controlled to within +/- 0.05% ( 2s). The precision of measurements of Pb isotope ratios is strongly dependent on ion beam intensities. Internal precision of <= 0.02% (2se) on (208)Pb/(206)Pb and (207)Pb/(206)Pb ratios requires Sigma Pb ion beam intensity of > similar to 30-50 mV. At beam intensities < 100 mV Sigma Pb measurement of (208)Pb/(204)Pb, (207)Pb/(204)Pb and (206)Pb/(204)Pb ratios also benefit significantly from the use of ion counting to measure (204)Pb intensity, with an overall improvement of 1-2 orders of magnitude in internal standard error. However, the additional uncertainty associated with calibration of the Faraday cup-ion counter relative gain suggest that use of Faraday cup to measure (204)Pb is most appropriate at signal intensities > similar to 200 mV, equivalent to similar to 100 000 counts per second (cps) (204)Pb. Correction for (204)Hg interference does not substantially contribute to uncertainty as long as (204)Hg comprises less than similar to 20% of the total 204 ion beam.
引用
收藏
页码:968 / 975
页数:8
相关论文
共 35 条
  • [21] Synthesis of a new olivine reference material by a novel method for in situ iron and magnesium isotope analyses using laser ablation MC-ICP-MS
    Zeng, Xianli
    Li, Ming
    Zhang, Wen
    Jin, Hongyun
    Liu, Yongsheng
    Hu, Zhaochu
    Luo, Tao
    Yang, Shengjun
    Liu, Zhenyan
    Wang, Jingyuan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2025, 40 (03) : 888 - 900
  • [22] Laser ablation MC ICP-MS U-Pb zircon dating using multiple channeltron ion counting detection
    Kosler, Jan
    Fliegel, Daniel
    Slama, Jiri
    Pedersen, Rolf-Birger
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A492 - A492
  • [23] In situ U-Pb zircon dating using laser ablation-multi ion counting-ICP-MS
    Hou, Kejun
    Tian, Yourong
    Li, Yanhe
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A552 - A552
  • [24] Precise and Accurate In Situ Determination of Lead Isotope Ratios in NIST, USGS, MPI-DING and CGSG Glass Reference Materials using Femtosecond Laser Ablation MC-ICP-MS
    Chen Kaiyun
    Yuan Honglin
    Bao Zhian
    Zong Chunlei
    Dai Mengning
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (01) : 5 - 21
  • [25] In situ Nd isotope analyses in geological materials with signal enhancement and non-linear mass dependent fractionation reduction using laser ablation MC-ICP-MS
    State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences, Wuhan
    430074, China
    不详
    ON
    K1A 0R6, Canada
    J Anal At Spectrom, 1 (232-244):
  • [26] In situ Nd isotope analyses in geological materials with signal enhancement and non-linear mass dependent fractionation reduction using laser ablation MC-ICP-MS
    Xu, Lei
    Hu, Zhaochu
    Zhang, Wen
    Yang, Lu
    Liu, Yongsheng
    Gao, Shan
    Luo, Tao
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (01) : 232 - 244
  • [27] Simultaneous in situ laser ablation analysis of Pb-U and Lu-Hf isotope ratios in zircons using MC-ICPMS
    Schwieters, J. B.
    Bouman, C.
    Deerberg, M.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2009, 73 (13) : A1188 - A1188
  • [28] IsoFishR: An application for reproducible data reduction and analysis of strontium isotope ratios (87Sr/86Sr) obtained via laser-ablation MC-ICP-MS
    Willmes, Malte
    Ransom, Katherine M.
    Lewis, Levi S.
    Denney, Christian T.
    Glessner, Justin J. G.
    Hobbs, James A.
    PLOS ONE, 2018, 13 (09):
  • [29] In-situ isotopic ratio analysis of iron using laser ablation-multiple collector-inductively coupled plasma mass spectrometry (LA-MC-ICP-MS)
    Hirata, T
    Ohno, T
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (05) : 487 - 491
  • [30] High spatial resolution in situ U-Pb dating using laser ablation multiple ion counting inductively coupled plasma mass spectrometry (LA-MIC-ICP-MS)
    Xie, Lie-Wen
    Yang, Jin-Hui
    Yin, Qing-Zhu
    Yang, Yue-Heng
    Liu, Jing-Bo
    Huang, Chao
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (05) : 975 - 986