Application of Dual-Energy Spectral Computed Tomography in Bone Mineral Density Measurement: Phantom and Clinical Research

被引:6
|
作者
Wang, Mingyue [1 ]
Wu, Yan [1 ]
Zhou, Yue [1 ]
Dong, Junqiang [1 ]
Hu, Shenshen [1 ]
Hou, Ping [1 ]
Gao, Jianbo [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiol, Zhengzhou, Peoples R China
关键词
dual-energy spectral computed tomography; quantitative computed tomography; bone mineral density; European spine phantom; spine; MATERIAL DECOMPOSITION; TRABECULAR BONE; CT; OSTEOPOROSIS; RECONSTRUCTION; ACCURACY; SPINE; FAT;
D O I
10.2147/IJGM.S381857
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Early detection and treatment of osteoporosis through bone mineral density (BMD) measurement could aid in the prevention of osteoporosis-related fractures. We aimed to assess the parameter of dual-energy spectral CT (DesCT) consistency with BMD determination using quantitative computed tomography (QCT), thereby establishing a basis for further DesCT application for BMD determination. Methods: We subjected the European spine phantom, which contains three vertebral bodies (V1, V2, and V3), to DesCT with different radiation doses. The basis material pairs were hydroxyapatite (water), calcium (water), and hydroxyapatite (fat). Additionally, the medical records of 152 patients who underwent QCT and DesCT for chest scans in a two-month period were reviewed to measure BMD values. Results: No significant differences were found in the basis pair values of the V1, V2, or V3 vertebrae under different radiation doses in the phantom; in particular, the hydroxyapatite (water), hydroxyapatite (fat), relative error values of V1, V2, and V3 under different radiation doses were not significantly different (all p > 0.05). For patients, the hydroxyapatite (water), hydroxyapatite (fat), and hydroxyapatite (average) values measured by DesCT had a significant correlation with BMD measured by QCT Among 242 vertebrae (152 T12 and 90 L1 vertebrae), there was no significant difference between the BMD measured by QCT and the HAP (average) measured by DesCT (p = 0.071). The interclass correlation coefficient (ICC) value was 0.925 between the HAP (average) and HAP (average) with DesCT and BMD measured by QCT (p < 0.001). Bland-Altman diagram indicated that both measurements were in good agreement. Discussion: We showed that BMD values measured by DesCT were stable and repeatable under different radiation doses. DesCT and QCT measurements of human BMD were highly correlated. Thus, DesCT-based BMD assessment of the spine in a clinical setting could be considered feasible.
引用
收藏
页码:6887 / 6896
页数:10
相关论文
共 50 条
  • [11] Virtual unenhanced images derived from dual-energy computed tomography for assessing bone mineral density and detecting osteoporosis
    Tong, Xiaoyu
    Fang, Xin
    Wang, Shigeng
    Fan, Yong
    Wei, Wei
    Xiao, Qingzhu
    Chen, Anliang
    Liu, Yijun
    Liu, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (10) : 6571 - 6582
  • [12] Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density
    Luke Arentsen
    Karen E. Hansen
    Masashi Yagi
    Yutaka Takahashi
    Ryan Shanley
    Angela McArthur
    Patrick Bolan
    Taiki Magome
    Douglas Yee
    Jerry Froelich
    Susanta K. Hui
    Journal of Bone and Mineral Metabolism, 2017, 35 : 428 - 436
  • [13] Use of dual-energy computed tomography to measure skeletal-wide marrow composition and cancellous bone mineral density
    Arentsen, Luke
    Hansen, Karen E.
    Yagi, Masashi
    Takahashi, Yutaka
    Shanley, Ryan
    McArthur, Angela
    Bolan, Patrick
    Magome, Taiki
    Yee, Douglas
    Froelich, Jerry
    Hui, Susanta K.
    JOURNAL OF BONE AND MINERAL METABOLISM, 2017, 35 (04) : 428 - 436
  • [14] PHANTOM-LESS BONE MINERAL DENSITY (BMD) MEASUREMENT USING DUAL ENERGY COMPUTED TOMOGRAPHY-BASED 3-MATERIAL DECOMPOSITION
    Hofmann, Philipp
    Sedlmair, Martin
    Krauss, Bernhard
    Wichmann, Julian L.
    Bauer, Ralf W.
    Flohr, Thomas G.
    Mahnken, Andreas H.
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [15] Principles and Clinical Application of Dual-energy Computed Tomography in the Evaluation of Cerebrovascular Disease
    Hsu, Charlie Chia-Tsong
    Kwan, Gigi Nga Chi
    Singh, Dalveer
    Pratap, Jit
    Watkins, Trevor William
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6
  • [16] Utility of Dual-Energy Computed Tomography in Clinical Conundra
    Abu-Omar, Ahmad
    Murray, Nicolas
    Ali, Ismail T.
    Khosa, Faisal
    Barrett, Sarah
    Sheikh, Adnan
    Nicolaou, Savvas
    Tamburrini, Stefania
    Iacobellis, Francesca
    Sica, Giacomo
    Granata, Vincenza
    Saba, Luca
    Masala, Salvatore
    Scaglione, Mariano
    DIAGNOSTICS, 2024, 14 (07)
  • [17] Clinical applications of dual-energy computed tomography in neuroradiology
    Tran, Ngoc-Anh
    Sodickson, Aaron D.
    Gupta, Rajiv
    Potter, Christopher A.
    SEMINARS IN ULTRASOUND CT AND MRI, 2022, 43 (04) : 280 - 292
  • [18] Clinical Applications of Dual-Energy Computed Tomography in the Liver
    Kim, Sooah
    Shuman, William P.
    SEMINARS IN ROENTGENOLOGY, 2016, 51 (04) : 284 - 291
  • [19] Traumatic bone marrow lesions in dual-energy computed tomography
    Ren, Qiuping
    Tang, Deqiu
    Xiong, Zhiyuan
    Zhao, Heng
    Zhang, Shuixing
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [20] Traumatic bone marrow lesions in dual-energy computed tomography
    Qiuping Ren
    Deqiu Tang
    Zhiyuan Xiong
    Heng Zhao
    Shuixing Zhang
    Insights into Imaging, 13