Biomonitoring for arsenic, toxic and essential metals in single hair strands by laser ablation inductively coupled plasma mass spectrometry

被引:19
|
作者
Kumtabtim, Usarat [1 ,2 ,3 ]
Matusch, Andreas [4 ]
Dani, Sergio Ulhoa [5 ]
Siripinyanond, Atitaya [2 ,3 ]
Becker, J. Sabine [1 ]
机构
[1] Forschungszentrum Julich, BrainMet Lab, Cent Div Analyt Chem, D-52425 Julich, Germany
[2] Mahidol Univ, Fac Sci, Dept Chem, Bangkok 10400, Thailand
[3] Mahidol Univ, Fac Sci, Ctr Innovat Chem, Bangkok 10400, Thailand
[4] Forschungszentrum Julich, Inst Neurosci & Med INM 2, D-52425 Julich, Germany
[5] Univ Heidelberg Hosp, Dept Internal Med, D-69120 Heidelberg, Germany
关键词
Arsenic; Biomonitoring; Hair strand; Laser ablation inductively coupled plasma mass spectrometry; Metal distribution; LA-ICP-MS; MICROWAVE DIGESTION; ELEMENTS; INDIVIDUALS; POPULATION; METABOLISM; EXPOSURE; ANTIMONY; PROVINCE; MERCURY;
D O I
10.1016/j.ijms.2011.03.007
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been developed as reliable analytical technique for the quantitation of metal distributions at micrometre resolution. In this work a novel microanalytical strategy for biomonitoring of arsenic, toxic and essential metals in single hair strands is proposed. Two different calibration strategies in LA-ICP-MS were developed using either certified hair standard reference material (IAEA 086) or prepared matrix-matched laboratory hair standards doped with analytes of interest at defined concentration. Powdered hair standards and human hair strands mounted on a sticky tape in the LA chamber were analyzed under the same experimental conditions by an optimized LA-ICP-MS technique. The use of hair powder standard allows calibration curves to be obtained by plotting the analyte ion (M(+)) intensity normalized to (34)S(+) (the ratio M(+)/(34)S(+)) as a function of the concentration determined by ICP-MS of acidic digests. The linear correlation coefficients (R) of calibration curves for analytes As, Ba, Cd, Ce, Co, Cr, Cu, Fe, Ga, Hg, Mg, Mo, Ni, Pb, Rb, Sr, Ti and U were typically between 0.985 and 0.999. The limit of detection (LOD) was 0.6 mu g g(-1) for As and ranged from 0.3 to 7.8 mu g g(-1) for the other analytes. Distinct elemental exposition time profiles were observed in hair samples from five volunteers. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 50 条
  • [31] TRACE-ELEMENTS DETERMINED ALONG SINGLE STRANDS OF HAIR BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    YOSHINAGA, J
    SHIBATA, Y
    MORITA, M
    CLINICAL CHEMISTRY, 1993, 39 (08) : 1650 - 1655
  • [32] Bioimaging of Metals and Biomolecules in Mouse Heart by Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Secondary Ion Mass Spectrometry
    Becker, J. Sabine
    Breuer, Uwe
    Hsieh, Hui-Fang
    Osterholt, Tobias
    Kumtabtim, Usarat
    Wu, Bei
    Matusch, Andreas
    Caruso, Joseph A.
    Qin, Zhenyu
    ANALYTICAL CHEMISTRY, 2010, 82 (22) : 9528 - 9533
  • [33] Quantitative images of metals in plant tissues measured by laser ablation inductively coupled plasma mass spectrometry
    Becker, J. S.
    Dietrich, R. C.
    Matusch, A.
    Pozebon, D.
    Dressier, V. L.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (11) : 1248 - 1252
  • [34] Analysis of heavy metals using laser-ablation inductively coupled plasma mass-spectrometry.
    Lee, KM
    Appleton, J
    Cooke, M
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1049 - 1049
  • [35] BIOIMAGING OF METALS BY LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY (LA-ICP-MS)
    Becker, J. Sabine
    Zoriy, Miroslav
    Matusch, Andreas
    Wu, Bei
    Salber, Dagmar
    Palm, Christoph
    Becker, J. Susanne
    MASS SPECTROMETRY REVIEWS, 2010, 29 (01) : 156 - 175
  • [36] Imaging mass spectrometry in biological tissues by laser ablation inductively coupled plasma mass spectrometry
    Becker, J. S.
    Su, J.
    Zoriya, M. V.
    Dobrowolska, J.
    Matusch, A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (01) : 1 - 6
  • [37] Soft ablation technique for laser ablation-inductively coupled plasma mass spectrometry
    Tokyo Inst of Technology, Tokyo, Japan
    J Anal At Spectrom, 11 (1337-1342):
  • [38] Monitoring of platinum in a single hair by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) after cisplatin
    Pozebon, Dirce
    Dressler, Valderi L.
    Matusch, Andreas
    Becker, J. Sabine
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2008, 272 (01) : 57 - 62
  • [39] Were Chinchorros exposed to arsenic? Arsenic determination in Chinchorro mummies' hair by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS)
    Byrne, Sam
    Amarasiriwardena, Dula
    Bandak, Basel
    Bartkus, Luke
    Kane, Jennifer
    Jones, Joseph
    Yanez, Jorge
    Arriaza, Bernardo
    Cornejo, Lorena
    MICROCHEMICAL JOURNAL, 2010, 94 (01) : 28 - 35
  • [40] Analysis of α-alumina samples by mass spectrometry with inductively coupled plasma and laser ablation
    Khvostikov, V. A.
    Karandashev, V. K.
    Burmii, Zh. P.
    INORGANIC MATERIALS, 2015, 51 (14) : 1410 - 1415