Biomonitoring for arsenic, toxic and essential metals in single hair strands by laser ablation inductively coupled plasma mass spectrometry

被引:19
|
作者
Kumtabtim, Usarat [1 ,2 ,3 ]
Matusch, Andreas [4 ]
Dani, Sergio Ulhoa [5 ]
Siripinyanond, Atitaya [2 ,3 ]
Becker, J. Sabine [1 ]
机构
[1] Forschungszentrum Julich, BrainMet Lab, Cent Div Analyt Chem, D-52425 Julich, Germany
[2] Mahidol Univ, Fac Sci, Dept Chem, Bangkok 10400, Thailand
[3] Mahidol Univ, Fac Sci, Ctr Innovat Chem, Bangkok 10400, Thailand
[4] Forschungszentrum Julich, Inst Neurosci & Med INM 2, D-52425 Julich, Germany
[5] Univ Heidelberg Hosp, Dept Internal Med, D-69120 Heidelberg, Germany
关键词
Arsenic; Biomonitoring; Hair strand; Laser ablation inductively coupled plasma mass spectrometry; Metal distribution; LA-ICP-MS; MICROWAVE DIGESTION; ELEMENTS; INDIVIDUALS; POPULATION; METABOLISM; EXPOSURE; ANTIMONY; PROVINCE; MERCURY;
D O I
10.1016/j.ijms.2011.03.007
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been developed as reliable analytical technique for the quantitation of metal distributions at micrometre resolution. In this work a novel microanalytical strategy for biomonitoring of arsenic, toxic and essential metals in single hair strands is proposed. Two different calibration strategies in LA-ICP-MS were developed using either certified hair standard reference material (IAEA 086) or prepared matrix-matched laboratory hair standards doped with analytes of interest at defined concentration. Powdered hair standards and human hair strands mounted on a sticky tape in the LA chamber were analyzed under the same experimental conditions by an optimized LA-ICP-MS technique. The use of hair powder standard allows calibration curves to be obtained by plotting the analyte ion (M(+)) intensity normalized to (34)S(+) (the ratio M(+)/(34)S(+)) as a function of the concentration determined by ICP-MS of acidic digests. The linear correlation coefficients (R) of calibration curves for analytes As, Ba, Cd, Ce, Co, Cr, Cu, Fe, Ga, Hg, Mg, Mo, Ni, Pb, Rb, Sr, Ti and U were typically between 0.985 and 0.999. The limit of detection (LOD) was 0.6 mu g g(-1) for As and ranged from 0.3 to 7.8 mu g g(-1) for the other analytes. Distinct elemental exposition time profiles were observed in hair samples from five volunteers. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 50 条
  • [21] Elemental fractionation in laser ablation inductively coupled plasma mass spectrometry
    Longerich, HP
    Gunther, D
    Jackson, SE
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (5-6): : 538 - 542
  • [22] Laser ablation inductively coupled plasma mass spectrometry: Principles and applications
    Mokgalaka, NS
    Gardea-Torresdey, JL
    APPLIED SPECTROSCOPY REVIEWS, 2006, 41 (02) : 131 - 150
  • [23] In torch laser ablation sampling for inductively coupled plasma mass spectrometry
    Tanner, M
    Gunther, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (09) : 987 - 989
  • [24] Petrochronology by Laser-Ablation Inductively Coupled Plasma Mass Spectrometry
    Kylander-Clark, Andrew R. C.
    PETROCHRONOLOGY: METHODS AND APPLICATIONS, 2017, 83 : 183 - +
  • [25] Laser-ablation inductively-coupled plasma mass spectrometry
    Günther, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) : 31 - 32
  • [26] Nanoparticle enhanced laser ablation inductively coupled plasma mass spectrometry
    Mangone, Annarosa
    Mastrorocco, Fabrizio
    Giannossa, Lorena Carla
    Comparelli, Roberto
    Dell'Aglio, Marcella
    De Giacomo, Alessandro
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 163 (163)
  • [27] Laser-ablation inductively-coupled plasma mass spectrometry
    Detlef Günther
    Analytical and Bioanalytical Chemistry, 2002, 372 : 31 - 32
  • [28] Spatial resolution in laser ablation inductively coupled plasma mass spectrometry
    Coedo, A. G.
    Dorado, M. T.
    REVISTA DE METALURGIA, 2010, 46 (01) : 52 - 68
  • [29] Resonant laser ablation of metals detected by atomic emission in a microwave plasma and by inductively coupled plasma mass spectrometry
    Cleveland, D
    Stchur, P
    Hou, XD
    Yang, KX
    Zhou, J
    Michel, RG
    APPLIED SPECTROSCOPY, 2005, 59 (12) : 1427 - 1444
  • [30] Determination of Toxic and Essential Elements in Urine by Inductively Coupled Plasma Mass Spectrometry
    Veikhman, G. A.
    Gilyova, O. V.
    Stenno, E. V.
    Ulanova, T. S.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2016, 8 (03) : 120 - 124