Gastric motility measurement and evaluation of functional dyspepsia by a bio-impedance method

被引:13
|
作者
Li, Zhangyong [1 ]
Ren, Chaoshi [1 ]
机构
[1] Chongqing Univ Posts & Telecommun, Coll Bioinformat, Chongqing 400065, Peoples R China
关键词
functional dyspepsia; electrical bioimpedance; gastric motility; synchronous EGG; wavelet transform;
D O I
10.1088/0967-3334/29/6/S31
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In order to investigate the complex course of the electrical and mechanical processes of functional dyspepsia (FD), it is necessary to extract gastric motility information on both electricity and mechanism. According to the clinical standardization, 36 volunteers with functional dyspepsia were selected. The signal processing device has been designed by Chongqing University of Posts and Telecommunications. Multi-resolution analysis (MRA) decomposed the two signals of impedance gastric motility (IGM) and electrogastrogram ( EGG) collected from the body surface. The wavelet transform is addressed to separate the IGM and EGG signals from impedance signals due to breathing and blood flow. By means of the energy and frequency spectrum analysis technique, the signals can be classified according to the dominant power and dominant frequency. Some indices, such as frequencies of EGG and IGM, signal power spectrum and dynamic spectrum, the rates of rhythm and power for the normal EGG and IGM and so on, can also be calculated. The primary experiments of gastric motility measurement and evaluation are executed by including healthy humans ( control group: CG) and patients with FD (pathologic group: PG). There are significant differences in the temporal-domain and frequency-domain properties between the two groups. The main frequency of the CG belongs to 2-4 CPM and is clear and very regular, while the main frequency of the PG is much disordered. The peak of the maximal power of the CG belongs to 2-4 CPM and 1-2 CPM for the PG. The percentage of normal frequency (PNF) for the CG is 0.704 +/- 0.255 and 0.402 +/- 1.145 for the PG. The frequency instability coefficient (FIC) for the CG is 0.182 +/- 0.059 and 0.374 +/- 0.086 for the PG. The percentage of normal power (PNP) for the CG is 0.592 +/- 0.044 and 0.468 +/- 0.142 for the PG. The power instability coefficient (PIC) for the CG is 1.576 +/- 0.481 and 4.006 +/- 0.711 for the PG. The results of the experiments show that the proposed method of impedance can be a potential tool for the noninvasive assessment of gastric motility under gastrointestinal physiology and pathology conditions.
引用
收藏
页码:S373 / S382
页数:10
相关论文
共 50 条
  • [41] Influence of the Frequency Resolution on the Excitation Signals Power in Bio-impedance Measurement
    Kallel, Ahmed Yahia
    Bouchaala, Dhouha
    Ben Elhaj, Yesmine
    Gunther, Thomas
    Kanoun, Olfa
    Derbel, Nabil
    PROCEEDINGS OF THE 2020 17TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD 2020), 2020, : 765 - 770
  • [42] Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement
    Wang, Ting-Wei
    Syu, Jhen-Yang
    Chu, Hsiao-Wei
    Sung, Yen-Ling
    Chou, Lin
    Escott, Endian
    Escott, Olivia
    Lin, Ting-Tse
    Lin, Shien-Fong
    BIOSENSORS-BASEL, 2022, 12 (03):
  • [43] Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access
    Hernandez, DJ
    Sinkov, VA
    Roberts, WW
    Allaf, ME
    Patriciu, A
    Jarrett, TW
    Kavoussi, LR
    Stoianovici, D
    JOURNAL OF UROLOGY, 2001, 166 (04): : 1520 - 1523
  • [44] GASTRIC MYOELECTRICAL ACTIVITY AND GASTROINTESTINAL MOTILITY IN PATIENTS WITH FUNCTIONAL DYSPEPSIA
    JEBBINK, HJA
    VANBERGEHENEGOUWEN, GP
    BRUIJS, PPM
    AKKERMANS, LMA
    SMOUT, AJPM
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1995, 25 (06) : 429 - 437
  • [45] An evaluation of the influence of a magnetic field on a human subject with the use of bio-impedance
    Papezova, S.
    Papez, V.
    INTERNATIONAL CONFERENCE ON MAGNETISM (ICM 2009), 2010, 200
  • [46] Design of dual-channel feedback current source for bio-impedance measurement
    Wang S.
    Liu K.
    Zhu T.
    Li F.
    Yao J.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2020, 41 (10): : 204 - 212
  • [47] Decomposition method of an electrical bio-impedance signal into cardiac and respiratory components
    Krivoshei, A.
    Kukk, V.
    Min, M.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (06) : S15 - S25
  • [48] Multi-channel independent source bio-impedance measurement and signal analysis
    Wu, Run-Ze
    Gao, Xiao-Rong
    Ouyang, Jing
    Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering, 2001, 14 (06):
  • [49] Synchronous primary signal processing for MIMO bio-impedance measurement on several frequencies
    Ronk, A.
    Toomessoo, J.
    BEC 2008: 2008 INTERNATIONAL BIENNIAL BALTIC ELECTRONICS CONFERENCE, PROCEEDINGS, 2008, : 313 - 316
  • [50] Design of Automatic Switching Bio-Impedance Analysis (BIA) for Body Fat Measurement
    Riyadi, Munawar A.
    Muthouwali, Achmad Ngaqib
    Prakoso, Teguh
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTER SCIENCE AND INFORMATICS (EECSI), 2017, : 172 - 176