Gastric motility measurement and evaluation of functional dyspepsia by a bio-impedance method

被引:13
|
作者
Li, Zhangyong [1 ]
Ren, Chaoshi [1 ]
机构
[1] Chongqing Univ Posts & Telecommun, Coll Bioinformat, Chongqing 400065, Peoples R China
关键词
functional dyspepsia; electrical bioimpedance; gastric motility; synchronous EGG; wavelet transform;
D O I
10.1088/0967-3334/29/6/S31
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In order to investigate the complex course of the electrical and mechanical processes of functional dyspepsia (FD), it is necessary to extract gastric motility information on both electricity and mechanism. According to the clinical standardization, 36 volunteers with functional dyspepsia were selected. The signal processing device has been designed by Chongqing University of Posts and Telecommunications. Multi-resolution analysis (MRA) decomposed the two signals of impedance gastric motility (IGM) and electrogastrogram ( EGG) collected from the body surface. The wavelet transform is addressed to separate the IGM and EGG signals from impedance signals due to breathing and blood flow. By means of the energy and frequency spectrum analysis technique, the signals can be classified according to the dominant power and dominant frequency. Some indices, such as frequencies of EGG and IGM, signal power spectrum and dynamic spectrum, the rates of rhythm and power for the normal EGG and IGM and so on, can also be calculated. The primary experiments of gastric motility measurement and evaluation are executed by including healthy humans ( control group: CG) and patients with FD (pathologic group: PG). There are significant differences in the temporal-domain and frequency-domain properties between the two groups. The main frequency of the CG belongs to 2-4 CPM and is clear and very regular, while the main frequency of the PG is much disordered. The peak of the maximal power of the CG belongs to 2-4 CPM and 1-2 CPM for the PG. The percentage of normal frequency (PNF) for the CG is 0.704 +/- 0.255 and 0.402 +/- 1.145 for the PG. The frequency instability coefficient (FIC) for the CG is 0.182 +/- 0.059 and 0.374 +/- 0.086 for the PG. The percentage of normal power (PNP) for the CG is 0.592 +/- 0.044 and 0.468 +/- 0.142 for the PG. The power instability coefficient (PIC) for the CG is 1.576 +/- 0.481 and 4.006 +/- 0.711 for the PG. The results of the experiments show that the proposed method of impedance can be a potential tool for the noninvasive assessment of gastric motility under gastrointestinal physiology and pathology conditions.
引用
收藏
页码:S373 / S382
页数:10
相关论文
共 50 条
  • [31] Evaluation of a new bio-impedance spectroscopy device in healthy Japanese
    Nakagawa, Hideto
    Sato, Yuji
    Toshimori, Hirotaka
    Fujimoto, Shouichi
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2015, 26 (3-4) : 97 - 102
  • [32] A method to detect heart rate based on electrical bio-impedance
    Li, Kun-Yang
    Chen, Wen-Hui
    Zheng, Lian-Rong
    Wang, Shan-Qing
    Li, Xian-Ming
    Liu, Guan-Zheng
    3RD ANNUAL INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS (ITA 2016), 2016, 7
  • [33] Pulse wave detection method based on the bio-impedance of the wrist
    He, Jianman
    Wang, Mengjun
    Li, Xiaoxia
    Li, Gang
    Lin, Ling
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (05):
  • [34] Method to Quantify the Effect of Passivation Layer in Bio-Impedance Sensors
    Narayanan
    Nikhhah, Mehdi
    Strobl, Jeannine S.
    Agah, Masoud
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3783 - +
  • [35] Effect of ginger Effect of ginger on gastric motility and symptoms of functional dyspepsiaon gastric motility and symptoms of functional dyspepsia
    Ming-Luen Hu
    Christophan K Rayner
    Seng-Kee Chuah
    Yeh-Pin Chou
    Yi-Chun Chiu
    King-Wah Chiu
    Tsung-Hui Hu
    World Journal of Gastroenterology, 2011, 17 (01) : 105 - 110
  • [36] A New Method for Detection of Leg Movement using Bio-impedance
    Kim, K. S.
    Lee, S. O.
    Kim, S. C.
    Kim, D. W.
    Seo, J. H.
    Kim, K. S.
    Song, C. G.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3956 - +
  • [37] Analysis of breast bio-impedance using a finite element method
    Zhao, X
    Ihara, A
    Kinouchi, Y
    Morimoto, T
    Takeuchi, M
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 753 - 754
  • [38] Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement
    Wang, Ting-Wei
    Syu, Jhen-Yang
    Chu, Hsiao-Wei
    Sung, Yen-Ling
    Chou, Lin
    Escott, Endian
    Escott, Olivia
    Lin, Ting-Tse
    Lin, Shien-Fong
    Biosensors, 2022, 12 (03):
  • [39] Measurement of bio-impedance characteristic of freshwater fish based on virtual instrument
    Huazhong Agricultural University, Wuhan 430070, China
    Nongye Jixie Xuebao, 2007, 9 (103-107):
  • [40] A High Frequency Read-Out Channel for Bio-Impedance Measurement
    Takhti, Mohammad
    Teng, Yueh-Ching
    Odame, Kofi
    2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 1514 - 1517