Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR

被引:10
|
作者
Dobnik, David [1 ]
Demsar, Tina [1 ]
Huber, Ingrid [2 ]
Gerdes, Lars [2 ]
Broeders, Sylvia [3 ]
Roosens, Nancy [3 ]
Debode, Frederic [4 ]
Berben, Gilbert [4 ]
Zel, Jana [1 ]
机构
[1] Natl Inst Biol NIB, Dept Biotechnol & Syst Biol, Vecna Pot 111, Ljubljana 1000, Slovenia
[2] Bavarian Hlth & Food Safety Author LGL, Vet Str 2, D-85764 Oberschleissheim, Germany
[3] Sci Inst Publ Hlth WIV ISP, J Wytsmanstr 14, B-1050 Brussels, Belgium
[4] Walloon Agr Res Ctr CRA W, Chaussee Namur 24, B-5030 Gembloux, Belgium
关键词
Digital PCR; Droplet digital PCR; Absolute quantification; Reference materials; GMO quantification; POLYMERASE-CHAIN-REACTION; MULTIPLEX QUANTIFICATION; MODIFIED ORGANISMS; GMO DETECTION; DNA; LECTIN;
D O I
10.1007/s00216-017-0711-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection.
引用
收藏
页码:211 / 221
页数:11
相关论文
共 50 条
  • [21] Inter-laboratory validation of EPA method 3200 for mercury speciation analysis using prepared soil reference materials
    Rahman, GMM
    Kingston, HMS
    Kern, JC
    Hartwell, SW
    Anderson, RF
    Yang, SY
    APPLIED ORGANOMETALLIC CHEMISTRY, 2005, 19 (03) : 301 - 307
  • [22] INTER-LABORATORY PRECISION IN BILIRUBIN ANALYSIS
    PERRY, BW
    LOUDERBACK, A
    DOUMAS, BT
    CLINICAL CHEMISTRY, 1981, 27 (06) : 1036 - 1036
  • [23] Inter-laboratory comparison of a digital multimeter measurement in Turkey
    M. Patan Alper
    Scientific Reports, 13
  • [24] Inter-laboratory comparison of a digital multimeter measurement in Turkey
    Patan Alper, M.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [25] Quartet metabolite reference materials for inter-laboratory proficiency test and data integration of metabolomics profiling
    Naixin Zhang
    Qiaochu Chen
    Peipei Zhang
    Kejun Zhou
    Yaqing Liu
    Haiyan Wang
    Shumeng Duan
    Yongming Xie
    Wenxiang Yu
    Ziqing Kong
    Luyao Ren
    Wanwan Hou
    Jingcheng Yang
    Xiaoyun Gong
    Lianhua Dong
    Xiang Fang
    Leming Shi
    Ying Yu
    Yuanting Zheng
    Genome Biology, 25
  • [26] Quartet metabolite reference materials for inter-laboratory proficiency test and data integration of metabolomics profiling
    Zhang, Naixin
    Chen, Qiaochu
    Zhang, Peipei
    Zhou, Kejun
    Liu, Yaqing
    Wang, Haiyan
    Duan, Shumeng
    Xie, Yongming
    Yu, Wenxiang
    Kong, Ziqing
    Ren, Luyao
    Hou, Wanwan
    Yang, Jingcheng
    Gong, Xiaoyun
    Dong, Lianhua
    Fang, Xiang
    Shi, Leming
    Yu, Ying
    Zheng, Yuanting
    GENOME BIOLOGY, 2024, 25 (01)
  • [27] RADON EMANATION RATE STUDIES - INTER-LABORATORY STANDARD REFERENCE MATERIALS AND THE EFFECTS OF POWDERING AND PELLETIZING
    MCCORKELL, RH
    CIM BULLETIN, 1986, 79 (894): : 66 - 69
  • [28] Design of a Reference Device for Surge Immunity Inter-laboratory Comparison
    Tas, Emrah
    Pythoud, Frederic
    Muehlemann, Beat
    2018 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2018, : 482 - 487
  • [29] Design of a Reference Device for Radiated Immunity Inter-laboratory Comparison
    Pythoud, Frederic
    Tas, Emrah
    2017 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2017,
  • [30] INTER-LABORATORY TRANSFER STUDIES WITH A CANDIDATE REFERENCE METHOD FOR UREA
    SAMPSON, EJ
    BAIRD, MA
    FAST, DM
    WITTE, DL
    CLINICAL CHEMISTRY, 1982, 28 (07) : 1558 - 1558