Pressure drop of R134a in mini channels with micro pin fins during flow boiling

被引:12
|
作者
Li, Jie [1 ]
Zhang, Dalin [1 ]
Yubing, Wang [1 ]
Chen, Weijian [1 ]
Zhu, Guangya [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Aerosp Engn, Key Lab Aircraft Environm Control & Life Support, Minist Ind & Informat Technol, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Mini channel; Micro pin fin; Flow boiling; Pressure drop; Two-phase friction multiplier; HEAT-TRANSFER; SERRATED FINS; LIQUID FLOW; PERFORMANCE; OPTIMIZATION; SHAPES; SINKS; TUBES; WATER; BANK;
D O I
10.1016/j.applthermaleng.2022.119195
中图分类号
O414.1 [热力学];
学科分类号
摘要
Flow boiling in mini channel with micro pin fin arrays is a promising technology for thermal management in various fields such as microelectronics, energy utilization and national defence. Understanding its flow char-acteristics is the pave stone for further structure optimization of two-phase microchannel heat sinks. However, previous studies paid few attentions to the effect of different structural parameters on its flow performance, especially for the application with long channels for practical evaporators in aircraft environmental control systems. In this paper, an experimental system was set up to investigate the flow boiling pressure drops of refrigerant R134a in a 300 mm long channel with micro pin fin arrays. The flow characteristics of staggered diamond pin fin arrays with different channel widths of 1.0, 1.2 and 1.4 mm and fin angles of 30 degrees, 60 degrees and 90 degrees were comprehensively investigated. The pin fins with a height of 0.5 mm were arranged in the rectangular channel through 3D printing. Two-phase pressure drops in the test section were then measured. The test range of vapor quality, mass flux, heat flux and saturation pressure were 0-1, 200-500 kg/m2s, 10.0-37.5 kW/m2 and 390-700 kPa respectively. Experimental results revealed that the smaller channel width and the greater diamond angle resulted in the greater two-phase pressure drops. The heat flux showed an insignificant influence on the two-phase pressure drops. The existing empirical correlations for pressure drops were evaluated and failed to predict the present experimental data. A new one with the consideration of pin fin structure parameters was then developed to improve the prediction accuracy with the maximum mean absolute deviation of 5.4 %. The pro-posed correlation can illuminate future study on flow boiling in mini channel with pin fin arrays and be bene-ficial for the practical design of two-phase microchannel heat sinks.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Experimental Investigation on Flow Boiling in Micro-channel with R32/R134a
    Guan, Xin
    Ma, Hu Gen
    Xie, Rong Jian
    Bai, Jian Mei
    Liu, Hong
    ADVANCES IN MECHANICAL DESIGN, PTS 1 AND 2, 2011, 199-200 : 1574 - +
  • [42] Flow boiling heat transfer and two-phase pressure drop of R134A in a microfinned helically coiled tube
    Cui, WZ
    Li, LJ
    Chen, QH
    Xin, MD
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2005, 19 (1-3): : 581 - 583
  • [43] An experimental study of flow boiling frictional pressure drop of R134a in a horizontal 1.002 mm tube under hypergravity
    Li, Guohua
    Fang, Xiande
    Yuan, Yuliang
    Chen, Yanyu
    Wang, Li
    Xu, Yu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 118 : 247 - 256
  • [44] Surface effects in flow boiling of R134a in microtubes
    Mahmoud, Mohamed M.
    Karayiannis, Tassos G.
    Kenning, David B. R.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (15-16) : 3334 - 3346
  • [45] Pressure Drop During Two-Phase Flow of R134a and R32 in a Single Minichannel
    Cavallini, Alberto
    Del Col, Davide
    Matkovic, Marko
    Rossetto, Luisa
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2009, 131 (03): : 1 - 8
  • [46] Experimental investigation on flow boiling heat transfer of R134a in a minichannel heatsink with copper foam fins
    Gao W.
    Fu K.
    Xu X.
    Liang X.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2022, 52 (02): : 333 - 342
  • [47] NUMERICAL SIMULATION OF THE FLOW BOILING HEAT TRANFER PERFORMANCE OF R134A IN A MICROCHANNEL EVAPORATOR WITH LOUVERED FINS
    Gossard, Justin J.
    Sommers, Andrew D.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 10, PTS A AND B, 2012, : 139 - 145
  • [48] Dryout characteristics during flow boiling of R134a in vertical circular minichannels
    Ali, Rashid
    Palm, Bjorn
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (11-12) : 2434 - 2445
  • [49] Pressure drop during condensation of R134a flowing inside a multiport minichannel
    Sakamatapan, Kittipong
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 75 : 31 - 39
  • [50] Pressure drop during reflux condensation of R134A in a small diameter tube
    Fiedler, S
    Auracher, H
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2004, 28 (2-3) : 139 - 144