Comparison of different immunoassays and GC-MS screening of benzodiazepines in urine

被引:21
|
作者
Augsburger, M [1 ]
Rivier, L [1 ]
Mangin, P [1 ]
机构
[1] Univ Lausanne, Inst Med Legale, CH-1005 Lausanne, Switzerland
关键词
benzodiazepines; screening; radioimmunoassays; KIMS; GC-MS;
D O I
10.1016/S0731-7085(98)00266-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A total of 53 urine samples were tested by different immunoassay methods and by gas chromatography/mass spectrometry to determine repeatability of the different methods and to assess whether the immunoassays performed on samples obtained from elderly patients of the emergency section could be considered as reliable enough for identifying a benzodiazepine consumption. Repeatability was excellent for GC/MS and good for immunoassays. The specificity was not different for the three immunoassays (96%). The sensitivity varied from 36, 64 to 75% for Online, RIA Immunalysis and RIA DPC, respectively. An other difference between immunoassays and GC/MS was the ability of GC/MS to detect lorazepam and low concentrations of benzodiazepines whereas immunoassays did not. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 50 条
  • [41] Analysis of Salvinorin A in urine using microextraction in packed syringe and GC-MS/MS
    Moreno, Ivo
    da Fonseca, Beatriz
    Oppolzer, David
    Martinho, Ana
    Barroso, Mario
    Cruz, Angelines
    Queiroz, Joao Antonio
    Gallardo, Eugenia
    BIOANALYSIS, 2013, 5 (06) : 661 - 668
  • [42] A sensitive GC-MS/MS method for the quantification of benzo[a]pyrene tetrol in urine
    Pilz, Fabian
    Gaertner, Antonia
    Pluym, Nikola
    Scherer, Gerhard
    Scherer, Max
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (12) : 2913 - 2928
  • [43] Detection and Confirmation of Ginsenosides in Horse Urine by GC-MS and LC-MS
    Chung, E. W.
    Kwok, W. H.
    Leung, D. K. K.
    Leung, G. N. W.
    Tang, F. P. W.
    Wan, T. S. M.
    Stewart, B. D.
    Watkins, K. L.
    CHROMATOGRAPHIA, 2009, 69 (9-10) : 923 - 932
  • [44] DETECTION TIMES OF MARIJUANA METABOLITES IN URINE BY IMMUNOASSAY AND GC-MS
    HUESTIS, MA
    MITCHELL, JM
    CONE, EJ
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (06) : 443 - 449
  • [45] Comparison of RapiTest(R) with Emit(R) dau(TM) and GC-MS for the analysis of drugs in urine
    Korte, T
    Pykalainen, J
    Lillsunde, P
    Seppala, T
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (01) : 49 - 53
  • [46] High throughput GC-MS confirmation and quantification of PCP in urine
    Cole, Jason
    Lambing, Matthew
    Robarge, Trisa
    LC GC EUROPE, 2006, : 39 - 39
  • [47] Rapid GC-MS confirmation of amphetamines in urine by extractive acylation
    Marais, Adriaan A. S.
    Laurens, Johannes B.
    FORENSIC SCIENCE INTERNATIONAL, 2009, 183 (1-3) : 78 - 86
  • [48] Determination of ibuprofen and its metabolites in human urine by GC-MS
    Yu, Daehyung
    Cho, Junghum
    Hong, Jongki
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2010, 23 (02): : 179 - 186
  • [49] A STEREOSPECIFIC GC-MS ASSAY FOR CROMAKALIM ENANTIOMERS IN PLASMA AND URINE
    GILL, TS
    ALLEN, GD
    DAVIES, BE
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1988, 26 (02) : P227 - P228
  • [50] Quantitation of neonicotinoid metabolites in human urine using GC-MS
    Nomura, Hiroshi
    Ueyama, Jun
    Kondo, Takaaki
    Saito, Isao
    Murata, Katsuyuki
    Iwata, Toyoto
    Wakusawa, Shinya
    Kamijima, Michihiro
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 941 : 109 - 115