Comparison of different immunoassays and GC-MS screening of benzodiazepines in urine

被引:21
|
作者
Augsburger, M [1 ]
Rivier, L [1 ]
Mangin, P [1 ]
机构
[1] Univ Lausanne, Inst Med Legale, CH-1005 Lausanne, Switzerland
关键词
benzodiazepines; screening; radioimmunoassays; KIMS; GC-MS;
D O I
10.1016/S0731-7085(98)00266-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A total of 53 urine samples were tested by different immunoassay methods and by gas chromatography/mass spectrometry to determine repeatability of the different methods and to assess whether the immunoassays performed on samples obtained from elderly patients of the emergency section could be considered as reliable enough for identifying a benzodiazepine consumption. Repeatability was excellent for GC/MS and good for immunoassays. The specificity was not different for the three immunoassays (96%). The sensitivity varied from 36, 64 to 75% for Online, RIA Immunalysis and RIA DPC, respectively. An other difference between immunoassays and GC/MS was the ability of GC/MS to detect lorazepam and low concentrations of benzodiazepines whereas immunoassays did not. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 50 条
  • [21] Profiles of urine samples taken from ecstasy users at rave parties: Analysis by immunoassays, HPLC, and GC-MS
    Zhao, HR
    Brenneisen, R
    Scholer, A
    McNally, AJ
    ElSohly, MA
    Murphy, TP
    Salamone, SJ
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (04) : 258 - 269
  • [22] Rapid sample pre-treatment prior to GC-MS and GC-MS/MS urinary toxicological screening
    Versace, Francois
    Sporkert, Frank
    Mangin, Patrice
    Staub, Christian
    TALANTA, 2012, 101 : 299 - 306
  • [23] COMPARATIVE-STUDY OF EXTRACTION METHODS FOR THE GC AND GC-MS SCREENING OF URINE FOR BETA-BLOCKER ABUSE
    DELBEKE, FT
    DEBACKERE, M
    DESMET, N
    MAERTENS, F
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (6-8) : 827 - 835
  • [24] The study on the measurement of formaldehyde in saliva and urine by GC-MS
    Shin, Ho-Sang
    Ahn, Hye-Sil
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2006, 19 (02): : 149 - 154
  • [25] GC-MS analysis of multiply derivatized opioids in urine
    Chen, Bud-Gen
    Wang, Sheng-Meng
    Liu, Ray H.
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (08): : 1012 - 1023
  • [26] Comparison between GC-MS and the EMIT (VIVATWIN) immunoassays for the determination of delta 9-THC-COOH
    Gheat, Y. H.
    TOXICOLOGY LETTERS, 2011, 205 : S87 - S87
  • [27] Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS
    Chang, Shu-Han
    Ho, Hui-Yu
    Zang, Chi-Zong
    Hsu, Ya-Hui
    Lin, Mei-Chih
    Tseng, Su-Hsiang
    Wang, Der-Yuan
    MASS SPECTROMETRY LETTERS, 2021, 12 (02) : 31 - 40
  • [28] A comparison of five commercial immunoassays for the detection of flunitrazepam and other benzodiazepines in urine
    Barrett, AM
    Walshe, K
    Kavanagh, PV
    McNamara, SM
    Moran, C
    Burdett, J
    Shattock, AG
    ADDICTION BIOLOGY, 1999, 4 (01) : 81 - 87
  • [29] GC OR GC-MS
    PRATZEL, B
    STURINO, E
    POLLUTION ENGINEERING, 1983, 15 (08) : 28 - 29
  • [30] UHPLC-HRMS and GC-MS Screening of a Selection of Synthetic Cannabinoids and Metabolites in Urine of Consumers
    Pellegrini, Manuela
    Marchei, Emilia
    Papaseit, Esther
    Farre, Magi
    Zaami, Simona
    MEDICINA-LITHUANIA, 2020, 56 (08): : 1 - 9