A Review on the Hemodialysis Reliable Outflow (HeRO) Graft for Haemodialysis Vascular Access

被引:52
|
作者
Al Shakarchi, J. [1 ,2 ]
Houston, J. G. [2 ,3 ]
Jones, R. G. [4 ]
Inston, N. [1 ,2 ]
机构
[1] Univ Hosp Birmingham, Queen Elizabeth Hosp Birmingham, Dept Renal Surg, Birmingham, W Midlands, England
[2] Univ Dundee, ReDVA Res Consortium, Dundee, Scotland
[3] Univ Dundee, Cardiovasc & Diabet Med, Dundee, Scotland
[4] Univ Hosp Birmingham, Dept Radiol, QEHB, Birmingham, W Midlands, England
关键词
Graft; Haemodialysis; HeRO; Outflow; Catheter; ARTERIOVENOUS GRAFTS; DIALYSIS ACCESS; END-STAGE; EXPERIENCE;
D O I
10.1016/j.ejvs.2015.03.059
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: With improved dialysis survival there are increasing numbers of patients who have exhausted definitive access options due to central venous stenosis and are maintaining dialysis on a central venous catheter. The Hemodialysis Reliable Outflow (HeRO) allows an alternative by providing a definitive access solution. The aim of this study is to systematically review the published outcomes of the HeRO graft and discuss the role in complex haemodialysis patients. Methods: Electronic databases were searched for studies assessing the use of the HeRO graft for dialysis in accordance with PRISMA published up to December 31 2014. The primary outcomes for this study were 1-year primary and secondary patency rates. Secondary outcomes were rates of dialysis access associated steal syndrome, HeRO-related bacteraemia rates and rates of interventions. Results: Following strict inclusion/exclusion criteria, eight studies including 409 patients were included in our review. Primary and secondary pooled patency rates in this complex cohort of dialysis patients were found to be 21.9% (9.6-37.2%) and 59.4% (39.4-78%). The rate of dialysis access associated steal syndrome was low at 6.3% (1-14.7%) as was the range of HeRO-related bacteraemia (0.13-0.7 events per 1000 days). Conclusions: This literature review shows that the HeRO graft is an acceptable option for complex dialysis patients who are catheter dependent. Owing to device availability, published data are predominantly North American and further longer-term studies in other populations may be necessary. In this challenging patient group, randomized controlled trials are required to allow comparisons with alternative access options. (C) 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [21] Hemodialysis Reliable Outflow (HeRO) graft creation in upper extremities abandoned due to stent obstruction via recanalization and HeRO outflow component insertion across stent interstices
    Cline, Brendan C.
    Zuchowski, Adam
    Gage, Shawn M.
    Martin, Jonathan G.
    Ronald, James
    Southerland, Kevin W.
    Lawson, Jeffrey H.
    Dillavou, Ellen D.
    Kim, Charles Y.
    JOURNAL OF VASCULAR ACCESS, 2023, 24 (05): : 989 - 993
  • [22] Examining Hemodialysis Reliable Outflow catheter performance and cost in hemodialysis access
    Torrent, Daniel J.
    Maness, Mandy R.
    Kachare, Swapnil D.
    Zink, Jill N.
    Haisch, Carl E.
    Harland, Robert C.
    Morgan, Claire
    Guyton, Rodney L.
    Colomb, Avery G.
    Barham, David W.
    Katz, Eric C.
    Stoner, Michael C.
    JOURNAL OF SURGICAL RESEARCH, 2014, 192 (01) : 1 - 5
  • [23] The Impact of Anticoagulation Use on Hemodialysis Reliable Outflow Graft Performance
    Terranella, Samantha
    Lineberger, Lance
    Hollinger, Edward
    Olaitan, Oyedolamu
    Hertl, Martin
    Tasse, Jordan
    Tabriz, David
    Chan, Edie
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : E238 - E238
  • [24] Salvaging Vascular Access and Treatment of Severe Limb Edema: Case Reports on the Novel Use of the Hemodialysis Reliable Outflow Vascular Access Device
    Gage, Shawn M.
    Ahluwalia, Hardeep S.
    Lawson, Jeffrey H.
    ANNALS OF VASCULAR SURGERY, 2011, 25 (03) : 387.e1 - 387.e5
  • [25] Two-stage Hemodialysis Reliable Outflow (HeRO) graft implantation technique that avoids the use of a femoral bridging dialysis catheter
    Yoon, William J.
    Lorelli, David R.
    JOURNAL OF VASCULAR ACCESS, 2015, 16 (01): : 64 - 67
  • [26] Not Quite a Hero (Hemodialysis Reliable Outflow Graft): A Rare Cause of Dyspnea and Positional Syncope in End Stage Renal Disease (ESRD)
    Anis, Mariam
    Harris, David
    Elwing, Jean
    CHEST, 2016, 150 (04) : 908A - 908A
  • [27] Avoiding the use of a femoral bridging catheter using a two-stage Hemodialysis Reliable Outflow (HeRO) graft implantation technique
    Yoon, William J.
    Lorelli, David R.
    JOURNAL OF VASCULAR ACCESS, 2015, 16 (03): : 189 - 194
  • [28] A multilayered electrospun graft as vascular access for hemodialysis
    Radakovic, D.
    Reboredo, J.
    Helm, M.
    Weigel, T.
    Schuerlein, S.
    Kupczyk, E.
    Leyh, R. G.
    Walles, H.
    Hansmann, J.
    PLOS ONE, 2017, 12 (10):
  • [29] A Case Series of Hemodialysis Reliable Outflow (Hero by Merit Medical) Associated Thromboembolic Events
    McLaughlin, J.
    Malik, O.
    Brown, A.
    King, C.
    Aryal, S.
    Walsh, P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201
  • [30] Paradoxical embolus following percutaneous thrombectomy of hemodialysis reliable outflow graft
    Gilmore, Brian
    Benrashid, Ehsan
    Youngwirth, Linda Marie
    Lawson, Jeffrey Harold
    JOURNAL OF VASCULAR ACCESS, 2015, 16 (06): : 533 - 536