Detection of Respiratory Phases to Estimate Breathing Pattern Parameters using Wearable Bioimpendace

被引:3
|
作者
Blanco-Almazan, Dolores [1 ,2 ,3 ]
Groenendaal, Willemijn [4 ]
Catthoor, Francky [5 ]
Jane, Raimon [1 ,2 ,3 ]
机构
[1] Inst Bioengn Catalonia IBEC BIST, Barcelona 08028, Spain
[2] Univ Politecn Cataluny, Dept Automat Control, ESAII, Barcelona 08034, Spain
[3] Biomed Res Network Ctr Bioengn Biomat & Nanomed C, Barcelona 08028, Spain
[4] Netherlands Holst Ctr, NL-5656 AE Eindhoven, Netherlands
[5] Katholieke Univ Leuven, B-3001 Leuven, Belgium
关键词
BIOIMPEDANCE; ALGORITHMS; SIGNALS; COPD;
D O I
10.1109/EMBC46164.2021.9630811
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many studies have focused on novel noninvasive techniques to monitor respiratory rate such as bioimpedance. We propose an algorithm to detect respiratory phases using wearable bioimpedance to compute time parameters like respiratory rate, inspiratory and expiratory times, and duty cycle. The proposed algorithm was compared with two other algorithms from literature designed to estimate the respiratory rate using physiological signals like bioimpedance. We acquired bioimpedance and airflow from 50 chronic obstructive pulmonary disease (COPD) patients during an inspiratory loading protocol. We compared performance of the algorithms by computing accuracy and mean average percentage error (MAPE) between the bioimpedance parameters and the reference parameters from airflow. We found similar performance for the three algorithms in terms of accuracy (>0.96) and respiratory time and rate errors (<3.42 %). However, the proposed algorithm showed lower MAPE in duty cycle (10.18 %), inspiratory time (10.65 %) and expiratory time (8.61 %). Furthermore, only the proposed algorithm kept the statistical differences in duty cycle between COPD severity levels that were observed using airflow. Accordingly, we suggest bioimpedance to monitor breathing pattern parameters in home situations. Clinical relevance- This study exhibits the suitability of wearable thoracic bioimpedance to detect respiratory phases and to compute accurate breathing pattern parameters.
引用
收藏
页码:5508 / 5511
页数:4
相关论文
共 50 条
  • [41] Feasibility of non-invasive respiratory drive and breathing pattern evaluation using CPAP in COVID-19 patients
    Dargent, Auguste
    Hombreux, Alexandra
    Roccia, Hugo
    Argaud, Laurent
    Cour, Martin
    Guerin, Claude
    JOURNAL OF CRITICAL CARE, 2022, 69
  • [42] Free-breathing radial imaging using a pilot-tone radiofrequency transmitter for detection of respiratory motion
    Solomon, Eddy
    Rigie, David S.
    Vahle, Thomas
    Paska, Jan
    Bollenbeck, Jan
    Sodickson, Daniel K.
    Boada, Fernando E.
    Block, Kai Tobias
    Chandarana, Hersh
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (05) : 2672 - 2685
  • [43] Using data on social contacts to estimate age-specific transmission parameters for respiratory-spread infectious agents
    Wallinga, Jacco
    Teunis, Peter
    Kretzschmar, Mirjam
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2006, 164 (10) : 936 - 944
  • [44] Estimation of breathing signal and the respiratory parameters from the speech recordings using honey badger-based modular neural system
    Patil, Mangal
    Naregalkar, Prajakta R.
    Tondare, Sharda
    Morbale, Jyoti
    Patil, Aparna S.
    MULTIMEDIA TOOLS AND APPLICATIONS, 2024, 83 (30) : 73957 - 73982
  • [45] FEASIBILITY OF DETECTION OF PERIODIC BREATHING USING RESPIRATORY SINUS ARRHYTHMIA PATTERNS FROM SLEEP TIME AMBULATORY ECG RECORDINGS
    Stein, P. K.
    Redline, S.
    SLEEP, 2011, 34 : A133 - A133
  • [46] Letter to the Editor: "Feasibility of non- invasive respiratory drive and breathing pattern evaluation using CPAP in COVID-19 patients"
    Esquinas, Antonio M.
    Bhakta, Pradipta
    O'Brien, Brian
    Mandal, Mohanchandra
    JOURNAL OF CRITICAL CARE, 2022, 72
  • [47] Application of balanced edge detection filters to estimate the location parameters of the causative sources using potential field data
    Ma, Guoqing
    Huang, Danian
    Liu, Cai
    JOURNAL OF APPLIED GEOPHYSICS, 2013, 99 : 18 - 23
  • [48] Author's response: "Feasibility of non- invasive respiratory drive and breathing pattern evaluation using CPAP in COVID-19 patients"
    Dargent, Auguste
    Hombreux, Alexandra
    Roccia, Hugo
    Argaud, Laurent
    Cour, Martin
    Guerin, Claude
    JOURNAL OF CRITICAL CARE, 2022, 72
  • [49] Accounting for Breathing Pattern Variability in Event-by-Event Respiratory Motion Correction in PET Using Dynamic Internal-External Motion Correlation
    Lu, Yihuan
    Fontaine, Kathryn
    Gallezot, Jean-Dominique
    Ren, Silin
    Mulnix, Tim
    Liu, Chi
    Carson, Richard E.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [50] Automated Explainable Detection of Cyclic Alternating Pattern (CAP) Phases and Sub-Phases Using Wavelet-Based Single-Channel EEG Signals
    Sharma, Manish
    Lodhi, Harsh
    Yadav, Rishita
    Sampathila, Niranjana
    Swathi, K. S.
    Acharya, U. Rajendra
    IEEE ACCESS, 2023, 11 : 50946 - 50961