Segmentation of Plaques in Sequences of Ultrasonic B-Mode Images of Carotid Arteries Based on Motion Estimation and a Bayesian Model

被引:77
|
作者
Destrempes, Francois [1 ]
Meunier, Jean [3 ,4 ]
Giroux, Marie-France [2 ,5 ]
Soulez, Gilles [2 ,3 ,5 ]
Cloutier, Guy [1 ,2 ,3 ]
机构
[1] Univ Montreal Hosp Res Ctr CRCHUM, Lab Biorheol & Med Ultrason, Montreal, PQ H2L 2W5, Canada
[2] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[4] Univ Montreal, Dept Comp Sci & Operat Res DIRO, Montreal, PQ H3C 3J7, Canada
[5] Univ Montreal Hosp Ctr CHUM, Dept Radiol, Montreal, PQ H2L 4M1, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
NONINVASIVE VASCULAR ELASTOGRAPHY; STRAIN; VARIABILITY; TRACKING;
D O I
10.1109/TBME.2011.2127476
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The goal of this paper is to perform a segmentation of atherosclerotic plaques in view of evaluating their burden and to provide boundaries for computing properties such as the plaque deformation and elasticity distribution (elastogram and modulogram). The echogenicity of a region of interest comprising the plaque, the vessel lumen, and the adventitia of the artery wall in an ultrasonic B-mode image was modeled by mixtures of three Nakagami distributions, which yielded the likelihood of a Bayesian segmentation model. The main contribution of this paper is the estimation of the motion field and its integration into the prior of the Bayesian model that included a local geometrical smoothness constraint, as well as an original spatiotemporal cohesion constraint. The Maximum A Posteriori of the proposed model was computed with a variant of the exploration/selection algorithm. The starting point is a manual segmentation of the first frame. The proposed method was quantitatively compared with manual segmentations of all frames by an expert technician. Various measures were used for this evaluation, including the mean point-to-point distance and the Hausdorff distance. Results were evaluated on 94 sequences of 33 patients (for a total of 8988 images). We report a mean point-to-point distance of 0.24 +/- 0.08 mm and a Hausdorff distance of 1.24 +/- 0.40 mm. Our tests showed that the algorithm was not sensitive to the degree of stenosis or calcification.
引用
收藏
页码:2202 / 2211
页数:10
相关论文
共 50 条
  • [41] Pixel distribution analysis of B-mode ultrasound images predicts differences in lipid cores of symptomatic vs. asymptomatic carotid plaques
    Lal, BK
    Hobson, RW
    Pappas, PJ
    Hameed, M
    Kubicka, R
    Jamil, Z
    Padberg, FT
    Duran, WN
    STROKE, 2002, 33 (01) : 372 - 372
  • [42] AUTOMATED REGISTRATION OF FREEHAND B-MODE ULTRASOUND AND MAGNETIC RESONANCE IMAGING OF THE CAROTID ARTERIES BASED ON GEOMETRIC FEATURES
    Carvalho, Diego D. B.
    Lorza, Andres Mauricio Arias
    Niessen, Wiro J.
    De Bruijne, Marleen
    Klein, Stefan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (01): : 273 - 285
  • [43] Integration of Multi-Plane Tissue Doppler and B-Mode Echocardiographic Images for Left Ventricular Motion Estimation
    Porras, A. R.
    Alessandrini, M.
    Mirea, O.
    D'hooge, J.
    Frangi, A. F.
    Piella, G.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (01) : 89 - 97
  • [44] Comparison of myocardial motion estimation methods based on simulated echocardiographic B-mode and RF data
    Tavakoli, Vahid
    Kemp, Jamie
    Dawn, Buddha
    Stoddard, Marcus
    Amini, Amir A.
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [45] Role of Fuzzy Pre-Classifier for High Performance LI/MA Segmentation in B-Mode Longitudinal Carotid Ultrasound Images
    Molinari, Filippo
    Gaetano, Laura
    Balestra, Gabriella
    Suri, Jasjit S.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4719 - 4722
  • [46] Evaluation of a Kalman-based block matching method to assess the bi-dimensional motion of the carotid artery wall in B-mode ultrasound sequences
    Zahnd, Guillaume
    Orkisz, Maciej
    Serusclat, Andre
    Moulin, Philippe
    Vray, Didier
    MEDICAL IMAGE ANALYSIS, 2013, 17 (05) : 573 - 585
  • [47] Multi-scale texture-based level-set segmentation of breast B-mode images
    Lang, Itai
    Sklair-Levy, Miri
    Spitzer, Hedva
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 72 : 30 - 42
  • [48] Automatic segmentation of tumors in B-Mode breast ultrasound images using information gain based neutrosophic clustering
    Lal, Madan
    Kaur, Lakhwinder
    Gupta, Savita
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (02) : 209 - 225
  • [49] Pixel distribution analysis of B-mode ultrasound scan images predicts histologic features of atherosclerotic carotid plaques (vol 35, pg 1210, 2002)
    Lal, BK
    Hobson, RW
    Pappas, PJ
    Kubicka, R
    Hameed, M
    Chakhtura, EY
    JOURNAL OF VASCULAR SURGERY, 2003, 38 (03) : 497 - 497
  • [50] Estimation of Tissue Attenuation from Ultrasonic B-Mode Images-Spectral-Log-Difference and Method-of-Moments Algorithms Compared
    Brandner, Dinah Maria
    Cai, Xiran
    Foiret, Josquin
    Ferrara, Katherine W.
    Zagar, Bernhard G.
    SENSORS, 2021, 21 (07)