Segmentation of Plaques in Sequences of Ultrasonic B-Mode Images of Carotid Arteries Based on Motion Estimation and a Bayesian Model

被引:77
|
作者
Destrempes, Francois [1 ]
Meunier, Jean [3 ,4 ]
Giroux, Marie-France [2 ,5 ]
Soulez, Gilles [2 ,3 ,5 ]
Cloutier, Guy [1 ,2 ,3 ]
机构
[1] Univ Montreal Hosp Res Ctr CRCHUM, Lab Biorheol & Med Ultrason, Montreal, PQ H2L 2W5, Canada
[2] Univ Montreal, Dept Radiol Radiooncol & Nucl Med, Montreal, PQ H3T 1J4, Canada
[3] Univ Montreal, Inst Biomed Engn, Montreal, PQ H3T 1J4, Canada
[4] Univ Montreal, Dept Comp Sci & Operat Res DIRO, Montreal, PQ H3C 3J7, Canada
[5] Univ Montreal Hosp Ctr CHUM, Dept Radiol, Montreal, PQ H2L 4M1, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
NONINVASIVE VASCULAR ELASTOGRAPHY; STRAIN; VARIABILITY; TRACKING;
D O I
10.1109/TBME.2011.2127476
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The goal of this paper is to perform a segmentation of atherosclerotic plaques in view of evaluating their burden and to provide boundaries for computing properties such as the plaque deformation and elasticity distribution (elastogram and modulogram). The echogenicity of a region of interest comprising the plaque, the vessel lumen, and the adventitia of the artery wall in an ultrasonic B-mode image was modeled by mixtures of three Nakagami distributions, which yielded the likelihood of a Bayesian segmentation model. The main contribution of this paper is the estimation of the motion field and its integration into the prior of the Bayesian model that included a local geometrical smoothness constraint, as well as an original spatiotemporal cohesion constraint. The Maximum A Posteriori of the proposed model was computed with a variant of the exploration/selection algorithm. The starting point is a manual segmentation of the first frame. The proposed method was quantitatively compared with manual segmentations of all frames by an expert technician. Various measures were used for this evaluation, including the mean point-to-point distance and the Hausdorff distance. Results were evaluated on 94 sequences of 33 patients (for a total of 8988 images). We report a mean point-to-point distance of 0.24 +/- 0.08 mm and a Hausdorff distance of 1.24 +/- 0.40 mm. Our tests showed that the algorithm was not sensitive to the degree of stenosis or calcification.
引用
收藏
页码:2202 / 2211
页数:10
相关论文
共 50 条
  • [31] Detection of carotid intima and media thicknesses based on ultrasound B-mode images clustered with Gaussian Mixture Model
    Qi, Guiling
    Zhang, Yufeng
    Li, Zhiyao
    Mo, Hong
    Chen, Jie
    ELEVENTH INTERNATIONAL CONFERENCE ON GRAPHICS AND IMAGE PROCESSING (ICGIP 2019), 2020, 11373
  • [32] Detection of carotid intima and media thicknesses based on ultrasound B-mode images clustered with Gaussian mixture model
    Qi G.
    He B.
    Zhang Y.
    Li Z.
    Mo H.
    Cheng J.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2020, 37 (06): : 1080 - 1088
  • [33] Segmentation of kidney from ultrasound B-mode images with texture-based classification
    Wu, Chia-Hsiang
    Sun, Yung-Nien
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 84 (2-3) : 114 - 123
  • [34] Carotid Artery B-Mode Ultrasound Image Segmentation based on Morphology, Geometry and Gradient Direction
    Sunarya, I. Made Gede
    Yuniarno, Eko Mulyanto
    Purnomo, Mauridhi Hery
    Sardjono, Tri Arief
    Sunu, Ismoyo
    Purnama, I. Ketut Eddy
    SECOND INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION, 2017, 10443
  • [35] Lipid-rich carotid artery plaques appear echolucent on ultrasound B-mode images and may be associated with intraplaque haemorrhage
    Gronholdt, MLM
    Wiebe, BM
    Laursen, H
    Nielsen, TG
    Schroeder, TV
    Sillesen, H
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (06) : 439 - 445
  • [36] An Optimized Method for B-Mode Echocardiographic Video Compression Based on Motion Estimation and Wavelet
    Sahba, Nima
    Maghooli, Keivan
    Tavakoli, Vahid
    INTERNATIONAL ARAB JOURNAL OF INFORMATION TECHNOLOGY, 2014, 11 (05) : 487 - 492
  • [37] Estimation of the myocardial activation sequence based on B-mode ultrasound cine-images
    Adam, D
    Rappaport, D
    Landesberg, A
    Konyukhov, E
    Smirin, N
    Lysyansky, P
    Friedman, Z
    COMPUTERS IN CARDIOLOGY 2005, VOL 32, 2005, 32 : 965 - 968
  • [38] Implementation of three different segmentation techniques for quantitative evaluation of IMT in B-mode ultrasound common carotid artery images
    Naik, Vaishali
    Gamad, R. S.
    Bansod, Prashant
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2016, 4 (05): : 317 - 326
  • [39] Contrast-enhanced ultrasonography vs B-mode ultrasound for visualization of intima-media thickness and detection of plaques in human carotid arteries
    Shah, Benoy N.
    Chahal, Navtej S.
    Kooner, Jaspal S.
    Senior, Roxy
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (05): : 723 - 730
  • [40] 3-DIMENSIONAL RECONSTRUCTION OF HUMAN CAROTID ARTERIES FROM IMAGES OBTAINED DURING NONINVASIVE B-MODE ULTRASOUND EXAMINATION
    ROSENFIELD, K
    BOFFETTI, P
    KAUFMAN, J
    WEINSTEIN, R
    RAZVI, S
    ISNER, JM
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (03): : 379 - 384