Correlations between central corneal power, axial length, anterior chamber depth and central corneal thickness of near-emmetropic young university students in Palestine

被引:0
|
作者
Aljarousha, Mohammed [1 ,2 ]
Daqa, Ansam A. [2 ]
Qanan, Fatma [2 ]
Murtaja, Haya [2 ]
Baraka, Nadeen [2 ]
机构
[1] Int Islamic Univ Malaysia, Fac Allied Hlth Sci, Dept Optometry & Visual Sci, Kuantan, Malaysia
[2] Islamic Univ Gaza, Fac Hlth Sci, Dept Optometry, Gaza, Palestine
来源
AFRICAN VISION AND EYE HEALTH JOURNAL | 2021年 / 80卷 / 01期
关键词
central corneal power; axial length; anterior chamber depth; ultrasonic pachymeter; automated refractometer-keratometer; corneal topography; Islamic University-Gaza; central corneal thickness; REFRACTIVE ERROR; CURVATURE; SHAPE; EYE;
D O I
10.4102/aveh.v80i1.571
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Researchers have found that the refractive states of the eye are influenced by a variety of variables. Aim: This study investigated the correlation between the central corneal power (CCP) and a number of variables, which include axial length (AL), anterior chamber depth (ACD) and the central corneal thickness (CCT) in near-emmetropic eyes of students. Setting: The study was conducted in the Optometry Laboratory of the Islamic University-Gaza (IUG), Palestine. Methods: In a prospective analysis, 200 near-emmetropic students were examined from February 2019 to May 2019 with an ultrasound scanner (A-scan), ultrasonic pachymeter and Visionix L79 automated refractometer Keratometer (ARK). Only the data of one eye were randomly chosen for investigation. Results: The means and standard deviations (s.d.) of the CCP, AL, ACD and CCT for male students (n = 97) were 43.19 dioptre (D) +/- 1.34 D, 23.54 mm +/- 0.68 mm, 3.59 mm +/- 0.26 mm and 549 mu m +/- 33 mu m, respectively. Furthermore, the means +/- s.d. of 103 female students were as follows: CCP 43.85 D +/- 1.43 D, AL 22.94 mm +/- 0.69 mm, ACD 3.35 mm +/- 0.25 mm and CCT 543 mu m +/- 35 mu m. There was a significant association between CCP and gender (p = 0.00). There was a negative significant correlation between CCP and AL for both the male (r = -0.64; p = 0.00) and the female (r = -0.71, p = 0.00) participants. Conclusion: This study provided information on CCP, AL, ACD and CCT in near-emmetropic eyes of adults. In male students, CCP was flatter and AL was longer when compared with female Palestinian students.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 30 条
  • [21] Changes in axial length, central cornea thickness, and anterior chamber depth after rhegmatogenous retinal detachment repair
    Huang, Chunmei
    Zhang, Tonghe
    Liu, Jian
    Ji, Qiang
    Tan, Ruili
    BMC OPHTHALMOLOGY, 2016, 16
  • [22] Changes in axial length, central cornea thickness, and anterior chamber depth after rhegmatogenous retinal detachment repair
    Chunmei Huang
    Tonghe Zhang
    Jian Liu
    Qiang Ji
    Ruili Tan
    BMC Ophthalmology, 16
  • [23] Short-term variation of central corneal thickness and axial anterior chamber depth of healthy eyes using Scheimpflug photography via the Oculus Pentacam
    Mathebula, S. D.
    Rubin, A.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2009, 68 (01): : 12 - 24
  • [24] Correlation Between Corneal Keratometry, Central Corneal Thickness and Anterior Chamber Depth as Measured by Wavelight OB 820 Biometer and Wavelight Oculyzer II in Preoperative Cataract Surgery Patients
    Humayun, Sadia
    Noor, Muqaddas
    Naqvi, Syed Abid Hussain
    Tarar, Muhammad Shahid
    Ishaq, Mazhar
    Yasmeen, Habiba
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (08): : 890 - 894
  • [25] Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCT
    O'Donnell, Clare
    Hartwig, Andreas
    Radhakrishnan, Hema
    CORNEA, 2012, 31 (09) : 983 - 988
  • [26] Comparison of Keratometry, Central Corneal Thickness, and Anterior Chamber Depth Results Measured With Nidek-AL Scan Biometry and Sirius Topography Devices
    Bayramoglu, Sadik Etka
    Sayin, Nihat
    Ekinci, Dilbade Yildiz
    Erdogan, Mehmet
    ISTANBUL MEDICAL JOURNAL, 2018, 19 (02): : 158 - 161
  • [27] Measurement of Ocular Pulse Amplitude Using Dynamic Contour Tonometry and the Influence of Central Corneal Thickness, Akial Lenght and Anterior Chamber Depth on the Measurements
    Erdurmus, Mesut
    Karadag, Remzi
    Keskin, Ugur Can
    Uzun, Feyza
    Hepsen, Ibrahim F.
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2007, 37 (06): : 414 - 419
  • [28] Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation
    Muriël Doors
    Lars P. J. Cruysberg
    Tos T. J. M. Berendschot
    John de Brabander
    Frenne Verbakel
    Carroll A. B. Webers
    Rudy M. M. A. Nuijts
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 1139 - 1146
  • [29] Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation
    Doors, Muriel
    Cruysberg, Lars P. J.
    Berendschot, Tos T. J. M.
    de Brabander, John
    Verbakel, Frenne
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 247 (08) : 1139 - 1146
  • [30] Intra-observer and inter-observer reliability and reproducibility of slit-lamp-adapted optical coherence tomography for evaluation of anterior chamber depth and central corneal thickness
    Sandler, Shlomit F.
    Zelefsky, Joseph R.
    Dorairaj, Syril
    Arthur, Stella N.
    Ritch, Robert
    Liebmann, Jeffrey M.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (04) : 299 - 303