Measurement of Ocular Pulse Amplitude Using Dynamic Contour Tonometry and the Influence of Central Corneal Thickness, Akial Lenght and Anterior Chamber Depth on the Measurements

被引:0
|
作者
Erdurmus, Mesut [1 ]
Karadag, Remzi [1 ]
Keskin, Ugur Can [1 ]
Uzun, Feyza [1 ]
Hepsen, Ibrahim F. [1 ]
机构
[1] Fatih Univ, Tip Fak Goz Hastaliklari AD, Alparslan Turkes Cad 57, TR-06510 Ankara, Turkey
关键词
Ocular pulse amplitude; dynamic contour tonometry; central corneal thickness; axial lenght; anterior chamber depth;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effects of age, sex, intraocular pressure (1OP), central corneal thickness (CCT), corneal curvature, anterior chamber depth (ACD) and axial length on OPA measurements using dynamic contour tonometer (DCT) in healthy subjects. Materials and methods: Fifty-three eyes of 53 healthy individuals were included in this prospective study. After keratometric measurements, OPA and IOP were measured using Pascal DCT under topical anesthesia. The CCT was determined with the aid of ultrasonic pachymeter. After that, ACD and axial length of the subjects were measured by A scan ultrasonography. Pearson correlation analysis was used to determine the association between OPA and other parameters. Results: The mean age of 53 subjects (34 female, 19 male) who were included in the study was 52,68 +/- 8,29 years. Mean OPA was 2,81 +/- 1,01 mm Hg. Mean IOP was 15,89 +/- 2,39 mm Hg, corneal curvature was 7,80 +/- 0,23 mm, CCT was 556,30 +/- 32,80 mu m, ACD was 2,91 +/- 0,32 mm and axial length was 23,14 +/- 1,10 mm. There was no correlation between OPA values and age, CCT or ACD of the subjects (p>0.05). There were significant negative correlations between OPA and axial length (p<0.001 r=-0.49) and between OPA and corneal curvature (p=0,024 r=-0,31). There was a significant positive correlation between OPA and IOP measurements (p=0,007 r=0,37). OPA values were statistically higher in females than in males (p=0,03). Conclusion: OPA values are found to be correlated with axial length, corneal curvature and IOP. There is no correlation between OPA and CCT. Since OPA measurements using DCT were less effected by corneal biomechanical properties, it gives more reliable information about ocular blood flow.
引用
收藏
页码:414 / 419
页数:6
相关论文
共 22 条
  • [1] Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry
    Hoffmann E.M.
    Grus F.-H.
    Pfeiffer N.
    BMC Ophthalmology, 4 (1) : 1 - 7
  • [2] Influence of age, central corneal thickness, and quality score on dynamic contour tonometry
    M L S Jordão
    A Pedroso de Carvalho Lupinacci
    E L Ferreira
    I J F Enomoto
    V P Costa
    Eye, 2009, 23 : 1364 - 1369
  • [3] Influence of age, central corneal thickness, and quality score on dynamic contour tonometry
    Jordao, M. L. S.
    de Carvalho Lupinacci, A. Pedroso
    Ferreira, E. L.
    Enomoto, I. J. F.
    Costa, V. P.
    EYE, 2009, 23 (06) : 1364 - 1369
  • [4] Comparison of dynamic contour tonometry and Goldmann applanation tonometry and their relationship to corneal properties, refractive error, and ocular pulse amplitude
    Erickson, Dina H.
    Goodwin, Denise
    Rollins, Michael
    Belaustegui, Amber
    Anderson, Chad
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2009, 80 (04) : 169 - 174
  • [5] Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, Ocular Response Analyzer, and Goldmann tonometry in glaucomatous eyes
    Annette, Hager
    Kristina, Loge
    Bernd, Schroeder
    Mark-Oliver, Fuellhas
    Wolfgang, Wiegand
    JOURNAL OF GLAUCOMA, 2008, 17 (05) : 361 - 365
  • [6] Influence of Corneal Thickness in Keratoconic Corneas on IOP Measurement with IOPen, iCare, Dynamic Contour Tonometry and Goldmann Applanation Tonometry
    Klamann, M. K. J.
    Maier, A. -K. B.
    Gonnermann, J.
    Ruokonen, P.
    Bertelmann, E.
    Torun, N.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2013, 230 (07) : 697 - 700
  • [7] Intraocular pressure and ocular pulse amplitude comparisons in different types of glaucoma using dynamic contour tonometry
    Punjabi, Omar S.
    Ho, ai-Ky V. Ho
    Kniestedt, Christoph
    Bostrom, Alan G.
    Stamper, Robert L.
    Lin, Shan C.
    CURRENT EYE RESEARCH, 2006, 31 (10) : 851 - 862
  • [8] Central Corneal Thickness, Anterior Chamber Depth, and Pupil Diameter Measurements Using Visante OCT, Orbscan, and Pentacam
    Yazici, Ahmet Taylan
    Bozkurt, Ercument
    Alagoz, Cengiz
    Alagoz, Nese
    Pekel, Gokhan
    Kaya, Vedat
    Yilmaz, Omer Faruk
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (02) : 127 - 133
  • [9] Central corneal thickness and anterior chamber depth measurement by Sirius (R) Scheimpflug tomography and ultrasound
    Jorge, J.
    Rosado, J. L.
    Diaz-Rey, J. A.
    Gonzalez-Meijome, J. M.
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 417 - 422
  • [10] Comparison of Anterior Chamber Depth and Central Corneal Thickness Measured Using Different Devices
    Jeung, Jae Gyun
    Gil, Tae Young
    Bae, Gi Hyun
    Shin, Seong Joo
    Chung, Sung Kun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (10): : 1570 - 1576