Accuracy of measurements of small changes in soft-tissue mass by dual-energy x-ray absorptiometry

被引:0
|
作者
Lands, LC
Hornby, L
Hohenkerk, JM
Glorieux, FH
机构
关键词
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To assess the ability of dual-energy x-ray absorptiometry (DXA) to measure accurately small changes in lean soft-tissue mass. DXA has recently been suggested as an accurate, noninvasive method for analysis of body composition. Design: Experimental use of DXA to assess human body composition before and after rapid saline infusion. Participants: Six healthy men. Outcome measures: Weight measurements, DXA scanning results and skinfold thicknesses taken on the first day of the experiment and on the second day, before and after rapid saline infusion. Results: After the infusion, the subjects' weight increased by a mean 2.26 kg (standard deviation 0.199 kg). At each of the four readings, there was a strong correlation between weight and DXA-derived total mass (r = 0.999) and between skinfold-derived fat-free mass and DXA-derived lean mass (r = 0.941 to 0.957). Following infusion, no differences were found between the measured and theoretical (i.e., preinfusion value plus weight change) values for total mass (p = 0.22), lean soft-tissue mass (p = 0.10) and lean mass (p = 0.09). The bias was -0.669 (95% confidence interval [CI] 0.18 to -1.49) for total mass, -0.65 (95% CI 0.16 to -1.47) for lean soft-tissue mass, and -0.14 (95% CI 0.11 to -0.38) for lean mass. Conclusions: DXA is an improvement over previous dual-energy technologies and appears to provide sufficient accuracy to detect small (less than 2.5 kg) changes in mass in individual, healthy men, over a short period and under non-steady-state conditions. Therefore, DXA may also be of practical use for longitudinal assessment of weight change.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 50 条
  • [41] DUAL-PHOTON AND DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR THE MEASUREMENT OF TOTAL-BODY BONE-MINERAL AND SOFT-TISSUE COMPOSITION
    FISCHER, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1993, 20 (04): : 281 - 282
  • [42] Ability of dual-energy X-ray absorptiometry to discriminate changes in fat and lean mass in mice
    Johnson, M
    Watts, A
    Nagy, T
    OBESITY RESEARCH, 2004, 12 : A116 - A117
  • [43] Accuracy and precision of in vivo bone mineral measurements in sheep using dual-energy X-ray absorptiometry
    Pouilles, JM
    Collard, P
    Tremollieres, F
    Frayssinet, P
    Railhac, JJ
    Cahuzac, JP
    Autefage, A
    Ribot, C
    CALCIFIED TISSUE INTERNATIONAL, 2000, 66 (01) : 70 - 73
  • [44] Assessing the accuracy of measurements obtained by dual-energy X-ray absorptiometry on pig carcasses and primal cuts
    Kipper, M.
    Marcoux, M.
    Andretta, I.
    Pomar, C.
    MEAT SCIENCE, 2019, 148 : 79 - 87
  • [45] ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY (DXA) FOR BODY-COMPOSITION MEASUREMENTS IN PEDIATRIC STUDIES
    ELLIS, K
    SHYPAILO, R
    PRATT, J
    MERSMANN, H
    POND, W
    FASEB JOURNAL, 1993, 7 (03): : A359 - A359
  • [46] Accuracy and Precision of In Vivo Bone Mineral Measurements in Sheep Using Dual-Energy X-ray Absorptiometry
    J. M. Pouilles
    P. Collard
    F. Tremollieres
    P. Frayssinet
    J. J. Railhac
    J. P. Cahuzac
    A. Autefage
    C. Ribot
    Calcified Tissue International, 2000, 66 : 70 - 73
  • [47] Measurement of soft tissue composition by dual energy X-ray absorptiometry
    Jebb, SA
    BRITISH JOURNAL OF NUTRITION, 1997, 77 (02) : 151 - 163
  • [48] Accuracy of Longitudinal Assessment of Visceral Adipose Tissue by Dual-Energy X-Ray Absorptiometry in Children with Obesity
    Dias, Katrin A.
    Ramos, Joyce S.
    Wallen, Matthew P.
    Davies, Peter S. W.
    Cain, Peter A.
    Leong, Gary M.
    Ingul, Charlotte B.
    Coombes, Jeff S.
    Keating, Shelley E.
    JOURNAL OF OBESITY, 2019, 2019
  • [49] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE CALCANEUS - COMPARISON WITH VERTEBRAL DUAL-ENERGY X-RAY ABSORPTIOMETRY AND QUANTITATIVE COMPUTED-TOMOGRAPHY
    LAVALJEANTET, AM
    BERGOT, C
    WILLIAMS, M
    DAVIDSON, K
    LAVALJEANTET, M
    CALCIFIED TISSUE INTERNATIONAL, 1995, 56 (01) : 14 - 18
  • [50] Measurement of changes in soft tissue mass and fat mass with weight change: Pencil- versus fan-beam dual-energy X-ray absorptiometry
    Tylavsky, FA
    Fuerst, T
    Nevitt, M
    Dockrell, M
    Wan, JY
    Cauley, J
    Harris, T
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 94 - 97