Accuracy of measurements of small changes in soft-tissue mass by dual-energy x-ray absorptiometry

被引:0
|
作者
Lands, LC
Hornby, L
Hohenkerk, JM
Glorieux, FH
机构
关键词
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To assess the ability of dual-energy x-ray absorptiometry (DXA) to measure accurately small changes in lean soft-tissue mass. DXA has recently been suggested as an accurate, noninvasive method for analysis of body composition. Design: Experimental use of DXA to assess human body composition before and after rapid saline infusion. Participants: Six healthy men. Outcome measures: Weight measurements, DXA scanning results and skinfold thicknesses taken on the first day of the experiment and on the second day, before and after rapid saline infusion. Results: After the infusion, the subjects' weight increased by a mean 2.26 kg (standard deviation 0.199 kg). At each of the four readings, there was a strong correlation between weight and DXA-derived total mass (r = 0.999) and between skinfold-derived fat-free mass and DXA-derived lean mass (r = 0.941 to 0.957). Following infusion, no differences were found between the measured and theoretical (i.e., preinfusion value plus weight change) values for total mass (p = 0.22), lean soft-tissue mass (p = 0.10) and lean mass (p = 0.09). The bias was -0.669 (95% confidence interval [CI] 0.18 to -1.49) for total mass, -0.65 (95% CI 0.16 to -1.47) for lean soft-tissue mass, and -0.14 (95% CI 0.11 to -0.38) for lean mass. Conclusions: DXA is an improvement over previous dual-energy technologies and appears to provide sufficient accuracy to detect small (less than 2.5 kg) changes in mass in individual, healthy men, over a short period and under non-steady-state conditions. Therefore, DXA may also be of practical use for longitudinal assessment of weight change.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 50 条
  • [21] Total body bone and soft tissue composition by dual-energy X-ray absorptiometry (DEXA).
    Mazess, RB
    Hanson, JA
    Barden, HS
    Nord, R
    JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 : S520 - S520
  • [22] ACRONYM FOR DUAL-ENERGY X-RAY ABSORPTIOMETRY
    WILSON, CR
    COLLIER, BD
    CARRERA, GF
    JACOBSON, DR
    RADIOLOGY, 1990, 176 (03) : 875 - 875
  • [23] Dual-energy x-ray absorptiometry in obesity
    Bazzocchi, Alberto
    Diano, Danila
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2014, 186 (01) : 48 - 48
  • [24] An Update on Dual-Energy X-Ray Absorptiometry
    Blake, Glen M.
    Fogelman, Ignac
    SEMINARS IN NUCLEAR MEDICINE, 2010, 40 (01) : 62 - 73
  • [25] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE NEWBORN
    SALLE, BL
    LAPILLONNE, A
    BRAILLON, P
    ARCHIVES FRANCAISES DE PEDIATRIE, 1993, 50 (07): : 545 - 546
  • [26] LIMITATIONS OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TOTHILL, P
    NORD, RH
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (02): : 398 - 399
  • [27] REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    CHILIBECK, P
    CALDER, A
    SALE, DG
    WEBBER, C
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (04): : 297 - 302
  • [28] Dual-energy X-Ray Absorptiometry: Interpreting Reports and Serial Measurements
    Bonnick, Sydney L.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2013, 56 (04): : 677 - 685
  • [29] Dual-energy x-ray absorptiometry in osteopetrosis
    Adler, IN
    Stine, KC
    Kurtzburg, J
    Kinder, DL
    Cox, KS
    Lensing, SY
    Seibert, JJ
    SOUTHERN MEDICAL JOURNAL, 2000, 93 (05) : 501 - 503
  • [30] Precision and accuracy of measuring changes in bone mineral density by dual-energy X-ray absorptiometry
    P. Tothill
    W. J. Hannan
    Osteoporosis International, 2007, 18 : 1515 - 1523