Accuracy of measurements of small changes in soft-tissue mass by dual-energy x-ray absorptiometry

被引:0
|
作者
Lands, LC
Hornby, L
Hohenkerk, JM
Glorieux, FH
机构
关键词
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To assess the ability of dual-energy x-ray absorptiometry (DXA) to measure accurately small changes in lean soft-tissue mass. DXA has recently been suggested as an accurate, noninvasive method for analysis of body composition. Design: Experimental use of DXA to assess human body composition before and after rapid saline infusion. Participants: Six healthy men. Outcome measures: Weight measurements, DXA scanning results and skinfold thicknesses taken on the first day of the experiment and on the second day, before and after rapid saline infusion. Results: After the infusion, the subjects' weight increased by a mean 2.26 kg (standard deviation 0.199 kg). At each of the four readings, there was a strong correlation between weight and DXA-derived total mass (r = 0.999) and between skinfold-derived fat-free mass and DXA-derived lean mass (r = 0.941 to 0.957). Following infusion, no differences were found between the measured and theoretical (i.e., preinfusion value plus weight change) values for total mass (p = 0.22), lean soft-tissue mass (p = 0.10) and lean mass (p = 0.09). The bias was -0.669 (95% confidence interval [CI] 0.18 to -1.49) for total mass, -0.65 (95% CI 0.16 to -1.47) for lean soft-tissue mass, and -0.14 (95% CI 0.11 to -0.38) for lean mass. Conclusions: DXA is an improvement over previous dual-energy technologies and appears to provide sufficient accuracy to detect small (less than 2.5 kg) changes in mass in individual, healthy men, over a short period and under non-steady-state conditions. Therefore, DXA may also be of practical use for longitudinal assessment of weight change.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 50 条
  • [1] DUAL-ENERGY X-RAY ABSORPTIOMETRY FOR THE MEASUREMENT OF BONE AND SOFT-TISSUE COMPOSITION
    TOTHILL, P
    CLINICAL NUTRITION, 1995, 14 (05) : 263 - 268
  • [2] ACCURACY OF MEASUREMENTS OF SMALL CHANGES IN SOFT-TISSUE MASS BY USE OF DUAL-PHOTON ABSORPTIOMETRY
    LANDS, LC
    HEIGENHAUSER, GJF
    GORDON, C
    JONES, NL
    WEBBER, CE
    JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (02) : 698 - 702
  • [3] Effects of variations in regional composition on soft tissue measurements by dual-energy X-ray absorptiometry
    Milliken, LA
    Going, SB
    Lohman, TG
    INTERNATIONAL JOURNAL OF OBESITY, 1996, 20 (07) : 677 - 682
  • [4] Bone mineral and soft tissue measurements by dual-energy X-ray absorptiometry during growth
    Tothill, P
    Hannan, WJ
    BONE, 2002, 31 (04) : 492 - 496
  • [5] Soft-Tissue R Values in Dual-Energy X-Ray Absorptiometry: Validation by Human Elemental Composition
    Wang, Zimian
    Pi-Sunyer, Xavier
    Heymsfield, Steven
    Zhu, Shankuan
    Chen, Zhao
    Pierson, Richard N., Jr.
    OBESITY, 2008, 16 : S123 - S123
  • [6] SOFT-TISSUE COMPOSITION AND BONE-MINERAL STATUS - EVALUATION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    LUKASKI, HC
    JOURNAL OF NUTRITION, 1993, 123 (02): : 438 - 443
  • [7] Use of dual-energy X-ray absorptiometry for the measurements of small quantities of mineral
    Lapillonne, A
    Braillon, PM
    Claris, O
    Ho, PS
    Delmas, PD
    Salle, BL
    BIOLOGY OF THE NEONATE, 1997, 71 (03): : 198 - 201
  • [8] Measuring fat mass in small birds by dual-energy X-ray absorptiometry
    Korine, C
    Daniel, S
    van Tets, IG
    Yosef, R
    Pinshow, B
    PHYSIOLOGICAL AND BIOCHEMICAL ZOOLOGY, 2004, 77 (03): : 522 - 529
  • [9] Dual-energy X-ray absorptiometry
    Braillon, Pierre
    Peretti, Noel
    NUTRITION CLINIQUE ET METABOLISME, 2011, 25 (02): : 91 - 96
  • [10] ACCURACY OF MEASUREMENTS OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY INVIVO
    SVENDSEN, OL
    HAARBO, J
    HASSAGER, C
    CHRISTIANSEN, C
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (05): : 605 - 608