A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry

被引:2
|
作者
Al-Haj, Abdalla [1 ]
Lagarde, Charlie [1 ]
Mahyoub, Fareed [1 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Biomed Phys, Riyadh 11211, Saudi Arabia
关键词
D O I
10.1093/rpd/ncl565
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
It is well known that spurious signals can occur in thermoluminescence dosimetry (TLD) whenever contaminants (i.e. dirt, oil, dust) are present on the surface of the TLD card or crystal during the read-out process. For TLD cards, the Teflon material can also contribute to the background noise and this contribution has been found to depend on the material's light absorption. These non-radiation-induced signals contribute to the total light output during TLD read-out and can lead to incorrect dosimetry especially for low-dose measurements such as personal dosimetry. However, these spurious signals are generally in the low-temperature channels and are mostly accompanied by abnormal glow curves. Most of the published reports dealing with this type of spurious TL signal are on the LiF:Mg,Ti (TLD-100) material. The relatively new TLD material, LiF:Mg,Cu,P, is more sensitive and has higher signal-to-noise ratio than the traditional LiF:Mg,Ti. In this study, the effects of disturbing signals to the LiF:Mg,Cu,P (TLD-100H) cards used in personal dosimetry are investigated and compared with those of LiF:Mg,Ti (TLD-100).
引用
收藏
页码:399 / 402
页数:4
相关论文
共 50 条
  • [1] A comparative analysis of three thermoluminescent phosphors LiF:Mg,Ti (TLD-100), LiF:Mg,Cu and LiF:Mg,Cu,P
    Srivastava, JK
    Bhatt, BC
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 191 - 194
  • [2] Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring
    Freire, L.
    Calado, A.
    Cardoso, J. V.
    Santos, L. M.
    Alves, J. G.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 646 - 650
  • [3] Investigation of the emission spectra of LiF:Mg,Ti (TLD-100) during thermoluminescence
    Biderman, S
    Horowitz, Y
    Oster, L
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 369 - 372
  • [4] Investigation of the emission spectra of LiF:Mg,Ti (TLD-100) during thermoluminescence
    Biderman, S
    Horowitz, Y
    Oster, L
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 369 - 372
  • [5] THERMOLUMINESCENCE OF LIF TLD-100 BY PHOTOTRANSFER
    SUNTA, CM
    WATANABE, S
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1976, 9 (08) : 1271 - &
  • [6] Application of LiF:Mg, Cu (TLD-100H) Dosimeters for in Diagnostic Radiology
    Sina, S.
    Zeinali, B.
    Karinnipourfard, M.
    Lotfalizadeh, F.
    Sadeghi, M.
    Faghihi, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 131 - 131
  • [7] Optical absorption and thermoluminescence studies in irradiated dosimetric LiF:Mg,Ti (TLD-100)
    Oster, L
    Horowitz, YS
    Issa, N
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 17 - 20
  • [8] The saga of the thermoluminescence (TL) mechanisms and dosimetric characteristics of LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Eliyahu, I
    JOURNAL OF LUMINESCENCE, 2019, 214
  • [9] Further studies in the reduction of residual in Harshaw TLD-100H (LiF:Mg,Cu,P)
    Ramlo, M.
    Moscovitch, M.
    Rotunda, J. E.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 217 - 219
  • [10] The investigation of the thermoluminescence emission bands of LiF:Mg,Ti (TLD-100) by a simple developed model
    Yazici, A.N.
    Öztürk, Z.
    Bedir, M.
    Turkish Journal of Physics, 2001, 25 (04): : 333 - 343