Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring

被引:18
|
作者
Freire, L. [1 ,2 ]
Calado, A. [1 ]
Cardoso, J. V. [1 ]
Santos, L. M. [1 ]
Alves, J. G. [1 ]
机构
[1] Inst Tecnol & Nucl, Dept Proteccao Radiol & Seguranca Nucl, P-2683953 Sacavem, Portugal
[2] Nucl Med Lab, P-1600121 Lisbon, Portugal
关键词
individual monitoring; extremity dosemeters; thermoluminescence;
D O I
10.1016/j.radmeas.2007.12.013
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this work the results aimed at assessing the performance of two types of LiF detectors, TLD-100 and TLD-100H. used in the context of extremity dosimetry are presented. Each detector variety was studied for reproducibility, batch homogeneity, residual dose, linearity and energy dependence using, when appropriate, the Sr-90/Y-90 radiation source built-in one of the Harshaw 6600 readers, the ISO narrow X-ray beams of N30, N40, N60, N80, N100 and N120 or the gamma radiations of Cs-137 and Co-60. Two calibration energies (N120 and (CS)-C-137) were also used. The reproducibility and linearity results indicate that both LiF:Mg,Ti and LiF:Mg,Cu,P performed equally well. However, LiF:Mg,Cu,P presents a higher residual signal. In terms of energy dependence, LiF:Mg,Cu,P shows less variation than LiF:Mg,Ti particularly when N120 is used as calibration radiation. This seems to be a more realistic setup since the energy of the most frequently used radioisotopes in Nuclear Medicine departments with single photon emission computed tomography (SPECT) use gamma radiation energies closer to N120 than to 137CS. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:646 / 650
页数:5
相关论文
共 50 条
  • [1] A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry
    Al-Haj, Abdalla
    Lagarde, Charlie
    Mahyoub, Fareed
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 399 - 402
  • [2] RADIATION DAMAGE IN LIF (TLD-100)
    DOPPKE, KP
    CAMERON, JR
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 624 - &
  • [3] ABSENCE OF FADING IN LIF (TLD-100)
    SUNTHARALINGAM, N
    CAMERON, JR
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 624 - +
  • [4] OSLD Energy Response Performance and Dose Accuracy at 24-1250 keV: Comparison with TLD-100H and TLD-100
    Kadir, A. B. A.
    Priharti, W.
    Samat, S. B.
    Dolah, M. T.
    2013 UKM FST POSTGRADUATE COLLOQUIUM, 2013, 1571 : 108 - 114
  • [5] Robust determination of effective atomic numbers for electron interactions with TLD-100 and TLD-100H thermoluminescent dosimeters
    Taylor, M. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (08): : 770 - 773
  • [6] THERMOLUMINESCENCE OF LIF TLD-100 BY PHOTOTRANSFER
    SUNTA, CM
    WATANABE, S
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1976, 9 (08) : 1271 - &
  • [7] TRAPPING CENTERS IN LIF TLD-100
    MOHARIL, SV
    SOLID STATE COMMUNICATIONS, 1980, 33 (06) : 697 - 700
  • [8] THERMOLUMINESCENCE OF LIF TLD-100 DOSIMETER CRYSTALS
    FAIRCHILD, RG
    MATTERN, PL
    LENGWEILER, K
    LEVY, PW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (06) : 366 - 372
  • [9] EFFECT OF ANNEALING ON THERMOLUMINESCENCE OF LIF (TLD-100)
    JAIN, VK
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1976, 38 (01): : K65 - K68
  • [10] THERMAL QUENCHING BY PHOTOTRANSFER IN LIF TLD-100
    KATHURIA, SP
    SUNTA, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (04): : 707 - 710