A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry

被引:2
|
作者
Al-Haj, Abdalla [1 ]
Lagarde, Charlie [1 ]
Mahyoub, Fareed [1 ]
机构
[1] King Faisal Specialist Hosp & Res Ctr, Dept Biomed Phys, Riyadh 11211, Saudi Arabia
关键词
D O I
10.1093/rpd/ncl565
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
It is well known that spurious signals can occur in thermoluminescence dosimetry (TLD) whenever contaminants (i.e. dirt, oil, dust) are present on the surface of the TLD card or crystal during the read-out process. For TLD cards, the Teflon material can also contribute to the background noise and this contribution has been found to depend on the material's light absorption. These non-radiation-induced signals contribute to the total light output during TLD read-out and can lead to incorrect dosimetry especially for low-dose measurements such as personal dosimetry. However, these spurious signals are generally in the low-temperature channels and are mostly accompanied by abnormal glow curves. Most of the published reports dealing with this type of spurious TL signal are on the LiF:Mg,Ti (TLD-100) material. The relatively new TLD material, LiF:Mg,Cu,P, is more sensitive and has higher signal-to-noise ratio than the traditional LiF:Mg,Ti. In this study, the effects of disturbing signals to the LiF:Mg,Cu,P (TLD-100H) cards used in personal dosimetry are investigated and compared with those of LiF:Mg,Ti (TLD-100).
引用
收藏
页码:399 / 402
页数:4
相关论文
共 50 条
  • [21] Evaluation of the entrance skin dose in animals undergoing diagnostic radiology using LiF, Mg, Ti thermoluminescence dosimetry (TLD-100)
    Sina S.
    Mirzaiee F.
    Padargani T.
    Zehtabian M.
    Ahrari S.
    Zehtabian, Mehdi (mehdizehtabian@yahoo.com), 1600, Mashhad University of Medical Sciences (13): : 118 - 124
  • [22] THERMOLUMINESCENCE SPECTRUM OF HEAVILY IRRADIATED LIF(TLD-100)
    JAIN, VK
    BAPAT, VN
    KATHURIA, SP
    JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1973, 6 (17): : L343 - L344
  • [23] Study of the effect of optical bleaching at selected photon energies on the optical absorption and thermoluminescence of LiF: Mg, Ti (TLD-100)
    Reshes, G.
    Druzhyna, S.
    Biderman, S.
    Eliyahu, I.
    Oster, L.
    Horowitz, Y. S.
    RADIATION MEASUREMENTS, 2017, 106 : 26 - 29
  • [24] The effect of cooling rate on the precision of measurement of glow peak 5 in the thermoluminescence of LiF:Mg,Ti (TLD-100)
    Bokobza, Yogev
    Biderman, Shlomo
    Horowitz, Yigal Shalom
    Oster, Leonid
    Eliyahu, Ilan
    Shapiro, Alex
    Nemirovsky, Dmitry
    Reshes, Galina
    Herman, Beny
    Einav, Hezy
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (04) : 423 - 427
  • [25] Ionisation density effects following optical excitation in LiF:Mg, Ti (TLD-100)
    Weiss, D.
    Horowitz, Y.
    Oster, L.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 206 - 209
  • [26] Dependence of sensitisation of LiF:Mg,Ti (TLD-100) on the partial readout end temperature
    Piters, TM
    Yoshimura, EM
    Okuno, E
    Sunta, CM
    Perez, R
    Aceves, R
    BarbozaFlores, M
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 207 - 210
  • [27] Some dosimetric characteristics of the high temperature TL in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    Margaliot, M.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 203 - 207
  • [28] Dose response of F center optical absorption in LiF:Mg,Ti (TLD-100)
    Biderman, S.
    Eliyahu, I.
    Horowitz, Y. S.
    Oster, L.
    RADIATION MEASUREMENTS, 2014, 71 : 237 - 241
  • [29] THERMOLUMINESCENCE OF LIF TLD-100 - GLOW-CURVE KINETICS
    FAIRCHILD, RG
    MATTERN, PL
    LENGWEILER, K
    LEVY, PW
    JOURNAL OF APPLIED PHYSICS, 1978, 49 (08) : 4523 - 4533
  • [30] A NEW INTERPRETATION OF THE THERMOLUMINESCENCE AND ISOTHERMAL DECAY OF LIF TLD-100
    SINGH, SD
    GARTIA, RK
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (01) : 119 - 123