Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis

被引:4
|
作者
Struik, T. [1 ]
Jaspers, J. E. N. [2 ]
Besselink, N. J. [1 ]
van Roermund, P. M. [3 ]
Plomp, S. [4 ]
Rudert, M. J. [5 ]
Lafeber, F. P. J. G. [1 ]
Mastbergen, S. C. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Rheumatol & Clin Immunol, F02-127,POB 85500, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Med Technol & Clin Phys, C01-230,POB 85500, NL-3508 GA Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Dept Orthoped, G05-228,POB 85500, NL-3508 GA Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Dept Anat, STR-0-201,POB 85500, NL-3508 GA Utrecht, Netherlands
[5] Orthoped Biomech Lab, 2181 Westlawn Bldg, Iowa City, IA 52242 USA
关键词
Joint distraction; Knee osteoarthritis; Joint specific; Personalized; Articulating; Biomechanical testing; ARTHROPLASTY DEVICE; REPLACEMENT; CARTILAGE; FORCE;
D O I
10.1016/j.clinbiomech.2017.08.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6 weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Methods: Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5 mm was performed within a range of motion of 30 deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. Findings: The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Interpretation: Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 50 条
  • [31] Altered tibiofemoral joint contact mechanics and kinematics in patients with knee osteoarthritis and episodic complaints of joint instability
    Farrokhi, Shawn
    Voycheck, Carrie A.
    Klatt, Brian A.
    Gustafson, Jonathan A.
    Tashman, Scott
    Fitzgerald, G. Kelley
    CLINICAL BIOMECHANICS, 2014, 29 (06) : 629 - 635
  • [32] Radiographic progression of knee osteoarthritis is associated with MRI abnormalities in both the patellofemoral and tibiofemoral joint
    de Lange-Brokaar, B. J. E.
    Bijsterbosch, J.
    Kornaat, P. R.
    Yusuf, E.
    Ioan-Facsinay, A.
    Zuurmond, A. -M.
    Kroon, H. M.
    Meulenbelt, I.
    Bloem, J. L.
    Kloppenburg, M.
    OSTEOARTHRITIS AND CARTILAGE, 2016, 24 (03) : 473 - 479
  • [33] Investigation of the Relationship Between Inflammation and Calcification in the Tibiofemoral Joint for the Early Prediction of Knee Osteoarthritis
    Lim, Marie Kimberly
    Song, Isabel
    Beyrer, Patrick
    Golden, Jacquelyn
    Fang, Nan
    Somani, Josiah
    Witmer, Charles
    Chen, Andy
    Lee, Jae
    Schneider, Ariella
    Jankelovits, Amanda
    Miguez, Sofia
    Baoer, Li
    Hoilund-Carlsen, Poul
    Alavi, Abass
    Rajapakse, Chamith
    JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 : 329 - 329
  • [34] ASSOCIATIONS BETWEEN THE MORPHOLOGICAL PARAMETERS OF PROXIMAL TIBIOFIBULAR JOINT AND CHANGES IN TIBIOFEMORAL JOINT STRUCTURES IN PATIENTS WITH KNEE OSTEOARTHRITIS
    Zhu, Z.
    Chang, J.
    Han, W.
    Zhao, Y.
    Kwoh, K.
    Hunter, D.
    Ding, C.
    OSTEOPOROSIS INTERNATIONAL, 2019, 30 : S369 - S369
  • [35] Joint distraction for knee osteoarthritis: protocol for a systematic review and meta-analysis
    Goh, En Lin
    Lou, Winston Choong Ngan
    Chidambaram, Swathikan
    Ma, Shaocheng
    SYSTEMATIC REVIEWS, 2018, 7
  • [36] Joint distraction for knee osteoarthritis: protocol for a systematic review and meta-analysis
    En Lin Goh
    Winston Choong Ngan Lou
    Swathikan Chidambaram
    Shaocheng Ma
    Systematic Reviews, 7
  • [37] ASSOCIATIONS BETWEEN THE MORPHOLOGICAL PARAMETERS OF PROXIMAL TIBIOFIBULAR JOINT AND CHANGES IN TIBIOFEMORAL JOINT STRUCTURES IN PATIENTS WITH KNEE OSTEOARTHRITIS
    Zhu, Z., Jr.
    Chang, J., Jr.
    Han, W., Jr.
    Zheng, S.
    Ruan, G.
    Cicuttini, F.
    Wluka, A.
    Ding, C.
    OSTEOARTHRITIS AND CARTILAGE, 2019, 27 : S371 - S372
  • [38] Is the lateral-view radiograph the optimal tool for assessing tibiofemoral joint space in knee osteoarthritis?
    Stefan Lohmander
    Nature Clinical Practice Rheumatology, 2006, 2 (5): : 248 - 249
  • [39] Patient with knee osteoarthritis demonstrates improved knee adduction moment after knee joint distraction: a case report
    Eijking, H. M.
    Verlaan, L.
    Emans, P.
    Boymans, T.
    Meijer, K.
    Senden, R.
    ACTA ORTHOPAEDICA BELGICA, 2024, 90 (01): : 147 - 153
  • [40] Relationship Between the Sagittal and Coronary Alignment of the Tibiofemoral Joint and the Medial Meniscus Extrusion in Knee Osteoarthritis
    Ikezu, Masahiro
    Kudo, Shintarou
    Mitsumori, Ryuzi
    Iseki, Wataru
    Shibukawa, Masato
    Iizuka, Yasuhiko
    Tsutsumi, Masahiro
    Hayashi, Hidetoshi
    HEALTHCARE, 2024, 12 (23)