The optimal timing for magnetic resonance imaging in long-term follow-up of patients after a complete correction of the Tetralogy of Fallot

被引:0
|
作者
Kantorova, A. [1 ]
Kaldararova, M. [1 ]
Neuschl, V [1 ]
Nosal, M. [1 ]
Masura, J. [1 ]
机构
[1] Childrens Cardiac Ctr, Natl Inst Cardiovasc Dis, SK-83351 Bratislava, Slovakia
关键词
tetralogy of Fallot; pulmonary regurgitation; cardiovascular magnetic resonance imaging; right ventricle; end-diastolic volume; end-systolic volume; PULMONARY VALVE-REPLACEMENT; ADULTS LATE; REGURGITATION; REPAIR; ECHOCARDIOGRAPHY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Long-term pulmonary regurgitation (PR) leads to right ventricular (RV) dilatation and dysfunction. In patients after a complete correction of the tetralogy of Fallot (TOF) it represents the most frequent and high risk late complication. Magnetic resonance imaging (MRI) is an objective possibility for RV measurements; on the other hand MRI is complicated and not always accessible method. Background: We analyzed echocardiography (ECHO) and MRI parameters regarding RV dilatation and function and the correlation between these two methods with the aim to define optimal ECHO parameters indicating a necessity for further investigations. Patients and methods: In 50 patients with TOF > 10 years, after a complete surgical correction, ECHO and MRI were performed. Results: ECHO finding of end-diastolic diameter (EDD) of RV > 30mm was detected in 13 patients (26%) and in 30 patients (60 %) RV EDD above 4 standard deviations (SD) their normal values was present. MRI finding of end-diastolic volume (EDV) > 160 ml/m(2) was present in 14 patients (28 %) and end-systolic volume (ESV) > 85 ml/m(2) in 17 patients (34 %). Significant correlations between ECHO and MRI RV diastolic measurements were found (p=0.0001, r=0.34, resp. p=0.001, r=0.39). PR was significantly affecting diastolic RV dilatation (p=0.0001), on the other hand. RV dysfunction resulted in systolic RV dilatation (p=0.007). PR did not correlate with RV function (p=0.56). Conclusions: MRI is a golden standard for exact RV measurements and for the indication of pulmonary valve replacement, but ECHO still can be used during long-term follow-up, defining the point for further and more exact RV measurements (Tab. 2, Fig. 11, Ref. 17). Full Text in free PDF www.bmj.sk.
引用
收藏
页码:679 / 685
页数:7
相关论文
共 50 条
  • [31] LATE FOLLOW-UP OF PATIENTS EVALUATED HEMODYNAMICALLY AFTER TOTAL CORRECTION OF TETRALOGY OF FALLOT
    GERSONY, WM
    BATTHANY, S
    BOWMAN, FO
    MALM, JR
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1973, 66 (02): : 209 - 213
  • [32] LONG-TERM FOLLOW-UP AFTER NORMAL STRESS PERFUSION ON CARDIAC MAGNETIC RESONANCE IMAGING
    Sozzi, Fabiola B.
    Iacuzio, Laura
    Civaia, Filippo
    Berthier, Frederic
    Rusek, Stephan
    Rossi, Philipe
    Bourlon, Francois
    Dreyfus, Gilles
    Dor, Vincent
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1147 - A1147
  • [33] Late complications following tetralogy of fallot repair: The need for long-term follow-up
    Ho, Kay Woon
    Tan, Ru San
    Wong, Keng Yean
    Tan, Teng Hong
    Shankar, Sriram
    Tan, Ju Le
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2007, 36 (11) : 947 - 953
  • [34] Long-term follow up of homograft function after pulmonary valve replacement in patients with tetralogy of Fallot
    Oosterhof, T.
    Meijboom, F. J.
    Vliegen, H. W.
    Hazekamp, M. G.
    Zwinderman, A. H.
    Bouma, B. J.
    Van Dijk, A. P. J.
    Mulder, B. J. M.
    EUROPEAN HEART JOURNAL, 2006, 27 : 396 - 397
  • [35] LONG-TERM EVALUATION AFTER TOTAL CORRECTION OF TETRALOGY OF FALLOT
    WATANABE, K
    MORIKAWA, M
    AIZAWA, Y
    SHIBATA, A
    MIYAMURA, H
    EGUCHI, S
    MATSUKAWA, T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1983, 47 (09): : 1047 - 1051
  • [36] Follow-up of tetralogy of Fallot after repair
    Van Aerschot, Isabelle
    Iserin, Laurence
    PRESSE MEDICALE, 2011, 40 (7-8): : 740 - 747
  • [37] Graft dysfunction and failure during long-term follow-up after pulmonary valve replacement in tetralogy of Fallot
    Bokma, J. P.
    Winter, M. M.
    Oosterhof, T.
    Vliegen, H. W.
    Van Dijk, A. P.
    Hazekamp, M. G.
    Koolbergen, D. R.
    Mulder, B. J. M.
    Bouma, B. J.
    EUROPEAN HEART JOURNAL, 2014, 35 : 587 - 587
  • [38] Follow-up aortic dilatation in patients with repaired tetralogy of Fallot using cardiovascular magnetic resonance
    Siripornpitak, Suvipaporn
    Sriprachyakul, Apichaya
    Wongmetta, Saruntorn
    Samankatiwat, Piya
    Mokarapong, Pirapat
    Wanitkun, Suthep
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2021, 8
  • [39] Long-Term Outcomes of Coronary Endarterectomy in Patients With Complete Imaging Follow-Up
    Shehada, Sharaf-Eldin
    Mourad, Fanar
    Balaj, Ilir
    El Gabry, Mohamed
    Wendt, Daniel
    Thielmann, Matthias
    Schlosser, Thomas
    Jakob, Heinz
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (04) : 730 - 737
  • [40] Long-term clinical and magnetic resonance imaging follow-up assessment of patients with lumbar spinal stenosis after laminectomy
    Herno, A
    Partanen, K
    Talaslahti, T
    Kaukanen, E
    Turunen, V
    Suomalainen, O
    Airaksinen, O
    SPINE, 1999, 24 (15) : 1533 - 1537