The optimal timing for magnetic resonance imaging in long-term follow-up of patients after a complete correction of the Tetralogy of Fallot

被引:0
|
作者
Kantorova, A. [1 ]
Kaldararova, M. [1 ]
Neuschl, V [1 ]
Nosal, M. [1 ]
Masura, J. [1 ]
机构
[1] Childrens Cardiac Ctr, Natl Inst Cardiovasc Dis, SK-83351 Bratislava, Slovakia
关键词
tetralogy of Fallot; pulmonary regurgitation; cardiovascular magnetic resonance imaging; right ventricle; end-diastolic volume; end-systolic volume; PULMONARY VALVE-REPLACEMENT; ADULTS LATE; REGURGITATION; REPAIR; ECHOCARDIOGRAPHY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Long-term pulmonary regurgitation (PR) leads to right ventricular (RV) dilatation and dysfunction. In patients after a complete correction of the tetralogy of Fallot (TOF) it represents the most frequent and high risk late complication. Magnetic resonance imaging (MRI) is an objective possibility for RV measurements; on the other hand MRI is complicated and not always accessible method. Background: We analyzed echocardiography (ECHO) and MRI parameters regarding RV dilatation and function and the correlation between these two methods with the aim to define optimal ECHO parameters indicating a necessity for further investigations. Patients and methods: In 50 patients with TOF > 10 years, after a complete surgical correction, ECHO and MRI were performed. Results: ECHO finding of end-diastolic diameter (EDD) of RV > 30mm was detected in 13 patients (26%) and in 30 patients (60 %) RV EDD above 4 standard deviations (SD) their normal values was present. MRI finding of end-diastolic volume (EDV) > 160 ml/m(2) was present in 14 patients (28 %) and end-systolic volume (ESV) > 85 ml/m(2) in 17 patients (34 %). Significant correlations between ECHO and MRI RV diastolic measurements were found (p=0.0001, r=0.34, resp. p=0.001, r=0.39). PR was significantly affecting diastolic RV dilatation (p=0.0001), on the other hand. RV dysfunction resulted in systolic RV dilatation (p=0.007). PR did not correlate with RV function (p=0.56). Conclusions: MRI is a golden standard for exact RV measurements and for the indication of pulmonary valve replacement, but ECHO still can be used during long-term follow-up, defining the point for further and more exact RV measurements (Tab. 2, Fig. 11, Ref. 17). Full Text in free PDF www.bmj.sk.
引用
收藏
页码:679 / 685
页数:7
相关论文
共 50 条
  • [21] Long-term follow-up of patients with acute myocarditis by magnetic resonance imaging
    Wagner, A
    Schulz-Menger, J
    Dietz, R
    Friedrich, MG
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2003, 16 (01) : 17 - 20
  • [22] Magnetic resonance imaging long-term follow-up of patients with neuromyelitis optica
    Krampia, Wolfgang
    Aboul-Enein, Fahmy
    Jeeel, Julia
    Kristoferitsch, Wolfgang
    MULTIPLE SCLEROSIS, 2008, 14 : S109 - S110
  • [23] Cardiovascular magnetic resonance in the follow-up of patients with corrected tetralogy of Fallot: A review
    Oosterhof, T
    Mulder, BJM
    Vliegen, HW
    de Roos, A
    AMERICAN HEART JOURNAL, 2006, 151 (02) : 265 - 272
  • [24] ELECTROPHYSIOLOGIC STUDY OF PATIENTS WITH VENTRICULAR DYSRHYTHMIAS DURING LONG-TERM FOLLOW-UP AFTER REPAIR OF TETRALOGY OF FALLOT
    SATOH, M
    AIZAWA, Y
    MURATA, M
    SUZUKI, K
    AIZAWA, M
    FUNAZAKI, T
    SHIBATA, A
    MIYAMURA, H
    EGUCHI, S
    MATSUKAWA, T
    JAPANESE HEART JOURNAL, 1988, 29 (01): : 69 - 77
  • [25] FOLLOW-UP STUDIES OF TETRALOGY OF FALLOT AFTER TOTAL CORRECTION
    ASADA, S
    NAKAMURA, K
    HASHIMOTO, K
    HONDA, M
    SHIBAGAKI, F
    TAKEDA, Y
    TORIYAMA, A
    HASEGAWA, M
    NISHII, K
    MATSUMOTO, Y
    YAMAMOTO, T
    JAPANESE CIRCULATION JOURNAL, 1969, 33 (09): : 970 - +
  • [26] Long-term follow-up and sex differences in adults operated for tetralogy of Fallot
    Quattrone, Alessia
    Lie, Oyvind H.
    Nestaas, Eirik
    de Lange, Charlotte
    Try, Kirsti
    Lindberg, Harald L.
    Skulstad, Helge
    Erikssen, Gunnar
    Edvardsen, Thor
    Haugaa, Kristina
    Estensen, Mette E.
    OPEN HEART, 2021, 8 (02):
  • [27] ADVANCED ECHOCARDIOGRAPHIC AND CMR FEATURES OF PATIENTS WITH REPAIRED TETRALOGY OF FALLOT IN THE LONG-TERM FOLLOW-UP
    Gozzi, Anna
    Cuppini, Elena
    Cattapan, Irene
    Basso, Alessia
    Fumanelli, Jennifer
    Di Candia, Angela
    Avesani, Martina
    Sirico, Domenico
    Castaldi, Biagio
    Reffo, Elena
    Cerutti, Alessia
    Biffanti, Roberta
    Di Salvo, Giovanni
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [28] Long-term follow-up of cardiopulmonary function and cardioechographic examinations in patients with repaired tetralogy of Fallot
    Teng, Li Yun
    Hsiao, Chun Yuan
    Weng, Ken Peng
    Chen, Chia Ching
    Tsai, Sen Wei
    Lin, Ko Long
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2024, 73
  • [29] LONG-TERM EVALUATION, PHYSICAL AND SPORTING ACTIVITIES, AFTER COMPLETE CORRECTION FOR TETRALOGY OF FALLOT
    BOUHOUR, JB
    LEFEVRE, M
    SOULARD, M
    POTIRONJOSSE, M
    LOUVET, S
    GROSSETETE, R
    REYNAUD, JP
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1984, 77 (05): : 543 - 549
  • [30] Cardiac magnetic resonance imaging in repaired tetralogy of Fallot: A longitudinal midterm follow-up study
    Houshmand, Golnaz
    Rahmati, Rahem
    Meftah, Elahe
    Zarimeidani, Fatemeh
    Khorgami, Mohammadrafi
    Ghorashi, Seyyed Mojtaba
    Fazeli, Amir
    Omidi, Negar
    Saedi, Sedigheh
    Motevalli, Marzieh
    Maleki, Majid
    Pouraliakbar, Hamidreza
    PLOS ONE, 2024, 19 (12):