The optimal timing for magnetic resonance imaging in long-term follow-up of patients after a complete correction of the Tetralogy of Fallot

被引:0
|
作者
Kantorova, A. [1 ]
Kaldararova, M. [1 ]
Neuschl, V [1 ]
Nosal, M. [1 ]
Masura, J. [1 ]
机构
[1] Childrens Cardiac Ctr, Natl Inst Cardiovasc Dis, SK-83351 Bratislava, Slovakia
关键词
tetralogy of Fallot; pulmonary regurgitation; cardiovascular magnetic resonance imaging; right ventricle; end-diastolic volume; end-systolic volume; PULMONARY VALVE-REPLACEMENT; ADULTS LATE; REGURGITATION; REPAIR; ECHOCARDIOGRAPHY;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Long-term pulmonary regurgitation (PR) leads to right ventricular (RV) dilatation and dysfunction. In patients after a complete correction of the tetralogy of Fallot (TOF) it represents the most frequent and high risk late complication. Magnetic resonance imaging (MRI) is an objective possibility for RV measurements; on the other hand MRI is complicated and not always accessible method. Background: We analyzed echocardiography (ECHO) and MRI parameters regarding RV dilatation and function and the correlation between these two methods with the aim to define optimal ECHO parameters indicating a necessity for further investigations. Patients and methods: In 50 patients with TOF > 10 years, after a complete surgical correction, ECHO and MRI were performed. Results: ECHO finding of end-diastolic diameter (EDD) of RV > 30mm was detected in 13 patients (26%) and in 30 patients (60 %) RV EDD above 4 standard deviations (SD) their normal values was present. MRI finding of end-diastolic volume (EDV) > 160 ml/m(2) was present in 14 patients (28 %) and end-systolic volume (ESV) > 85 ml/m(2) in 17 patients (34 %). Significant correlations between ECHO and MRI RV diastolic measurements were found (p=0.0001, r=0.34, resp. p=0.001, r=0.39). PR was significantly affecting diastolic RV dilatation (p=0.0001), on the other hand. RV dysfunction resulted in systolic RV dilatation (p=0.007). PR did not correlate with RV function (p=0.56). Conclusions: MRI is a golden standard for exact RV measurements and for the indication of pulmonary valve replacement, but ECHO still can be used during long-term follow-up, defining the point for further and more exact RV measurements (Tab. 2, Fig. 11, Ref. 17). Full Text in free PDF www.bmj.sk.
引用
收藏
页码:679 / 685
页数:7
相关论文
共 50 条
  • [1] Cardiac Magnetic Resonance in long term follow-up of Tetralogy of Fallot
    Arancibia G, Ma. Francisca
    Valderrama E, Paulo
    Urcelay M, Gonzalo
    Becker R, Pedro
    Gonzalez F, Rodrigo
    Toro R, Lida
    Parra R, Rodrigo
    REVISTA CHILENA DE PEDIATRIA-CHILE, 2018, 89 (03): : 361 - 367
  • [2] Long-term follow-up in adults after tetralogy of Fallot repair
    Natalia Dłużniewska
    Piotr Podolec
    Maciej Skubera
    Monika Smaś-Suska
    Jacek Pająk
    Małgorzata Urbańczyk-Zawadzka
    Wojciech Płazak
    Maria Olszowska
    Lidia Tomkiewicz-Pająk
    Cardiovascular Ultrasound, 16
  • [3] Long-Term Electrocardiographic Follow-Up after Repair of Tetralogy of Fallot
    Massin, Martial M.
    Malekzadeh-Milani, Sophie G.
    Schifflers, Stefan
    Dessy, Hugues
    Verbeet, Thierry
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2011, 16 (04) : 336 - 343
  • [4] Long-term follow-up in adults after tetralogy of Fallot repair
    Dluzniewska, Natalia
    Podolec, Piotr
    Skubera, Maciej
    Smas-Suska, Monika
    Pajak, Jacek
    Urbanczyk-Zawadzka, Malgorzata
    Plazak, Wojciech
    Olszowska, Maria
    Tomkiewicz-Pajak, Lidia
    CARDIOVASCULAR ULTRASOUND, 2018, 16
  • [5] LONG-TERM PSYCHOLOGICAL FOLLOW-UP OF PATIENTS AFTER CORRECTIVE SURGERY FOR TETRALOGY OF FALLOT
    BAER, PE
    FREEDMAN, DA
    GARSON, A
    JOURNAL OF THE AMERICAN ACADEMY OF CHILD AND ADOLESCENT PSYCHIATRY, 1984, 23 (05): : 622 - 625
  • [6] Ablation of atrial tachyarrhythmias Late after surgical correction of tetralogy of Fallot: Long-term follow-up
    Orczykowski, Michal
    Borowiec, Karolina
    Biernacka, Elzbieta
    Bodalski, Robert
    Urbanek, Piotr
    Derejko, Pawel
    Kodziszewska, Katarzyna
    Wozniak, Olgierd
    Florczak, Aneta
    Marcinkiewicz, Kamil
    Guzek, Krystyna
    Fil, Agnieszka
    Warminski, Grzegorz
    Hoffman, Piotr
    Bilinska, Maria
    Szumowski, Lukasz
    KARDIOLOGIA POLSKA, 2018, 76 (07) : 1097 - 1105
  • [7] TOTAL CORRECTION OF TETRALOGY OF FALLOT AT AGE 40 AND OLDER - LONG-TERM FOLLOW-UP
    HU, DC
    SEWARD, JB
    PUGA, FJ
    FUSTER, V
    TAJIK, AJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (02) : 651 - 651
  • [8] TOTAL CORRECTION OF TETRALOGY OF FALLOT IN ADULTS - SURGICAL RESULTS AND LONG-TERM FOLLOW-UP
    PARK, IS
    LEACHMAN, RD
    COOLEY, DA
    TEXAS HEART INSTITUTE JOURNAL, 1987, 14 (02) : 160 - 169
  • [9] Long-Term Follow-Up in Repaired Tetralogy of Fallot: Can Deformation Imaging Help Identify Optimal Timing of Pulmonary Valve Replacement?
    Rotes, Anna Sabate
    Bonnichsen, Crystal R.
    Reece, Chelsea L.
    Connolly, Heidi M.
    Burkhart, Harold M.
    Dearani, Joseph A.
    Eidem, Benjamin W.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (12) : 1305 - 1310
  • [10] Long-term follow-up of patients with tetralogy of Fallot and implantable cardioverter defibrillator
    Waldmann, V
    Bouzeman, A.
    Duthoit, G.
    Koutbi, R.
    Bessiere, F.
    Labombarda, F.
    Marquie, C.
    Gourraud, J. B.
    Ladouceur, M.
    Mondoly, P.
    Sacher, F.
    Iserin, L.
    Thambo, J. B.
    Combes, N.
    Marijon, E.
    EUROPEAN HEART JOURNAL, 2020, 41 : 792 - 792