Effects of Inflow and Radiofrequency Spoiling on the Arterial Input Function in Dynamic Contrast-Enhanced MRI: A Combined Phantom and Simulation Study

被引:35
|
作者
Garpebring, Anders [1 ]
Wirestam, Ronnie [2 ]
Ostlund, Nils [3 ]
Karlsson, Mikael [1 ]
机构
[1] Umea Univ, Dept Radiat Sci, Div Radiat Phys, SE-90187 Umea, Sweden
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Umea Univ Hosp, Dept Radiat Sci, Div Biomed Engn & Informat, S-90185 Umea, Sweden
基金
瑞典研究理事会;
关键词
dynamic contrast-enhanced MRI; arterial input function; blood flow effects; RF spoiling; HIGH-TEMPORAL-RESOLUTION; FAST GRADIENT-ECHO; BLOOD-VOLUME; IMPROVED ACCURACY; T-1; MEASUREMENT; FLOWING BLOOD; PERMEABILITY; PERFUSION; T1; QUANTIFICATION;
D O I
10.1002/mrm.22760
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The arterial input function is crucial in pharmacokinetic analysis of dynamic contrast-enhanced MRI data. Among other artifacts in arterial input function quantification, the blood inflow effect and nonideal radiofrequency spoiling can induce large measurement errors with subsequent reduction of accuracy in the pharmacokinetic parameters. These errors were investigated for a 3D spoiled gradient-echo sequence using a pulsatile flow phantom and a total of 144 typical imaging settings. In the presence of large inflow effects, results showed poor average accuracy and large spread between imaging settings, when the standard spoiled gradient-echo signal equation was used in the analysis. For example, one of the investigated inflow conditions resulted in a mean error of about 40% and a spread, given by the coefficient of variation, of 20% for K-trans. Minimizing inflow effects by appropriate slice placement, combined with compensation for nonideal radiofrequency spoiling, significantly improved the results, but they remained poorer than without flow (e. g., 3-4 times larger coefficient of variation for K-trans). It was concluded that the 3D spoiled gradient-echo sequence is not optimal for accurate arterial input function quantification and that correction for nonideal radiofrequency spoiling in combination with inflow minimizing slice placement should be used to reduce the errors. Magn Reson Med 65:1670-1679, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:1670 / 1679
页数:10
相关论文
共 50 条
  • [21] Simple Change Improves the Arterial Input Function in Dynamic Contrast Enhanced MRI
    Haney, Chad R.
    ACADEMIC RADIOLOGY, 2022, 29 (06) : 804 - 805
  • [22] Dynamic Contrast-Enhanced MRI in Mice at High Field: Estimation of the Arterial Input Function Can be Achieved by Phase Imaging
    Fruytier, A. -C.
    Magat, J.
    Colliez, F.
    Jordan, B.
    Cron, G.
    Gallez, B.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 544 - 550
  • [23] Influence of arterial input function (AIF) on quantitative prostate dynamic contrast-enhanced (DCE) MRI and zonal prostate anatomy
    Ziayee, F.
    Mueller-Lutz, A.
    Gross, J.
    Quentin, M.
    Ullrich, T.
    Heusch, P.
    Arsov, C.
    Rabenalt, R.
    Albers, P.
    Antoch, G.
    Wittsack, H. J.
    Schimmoeller, L.
    MAGNETIC RESONANCE IMAGING, 2018, 53 : 28 - 33
  • [24] Improving the pharmacokinetic parameter measurement in dynamic contrast-enhanced MRI by use of the arterial input function: Theory and clinical application
    Yang, Xiangyu
    Liang, Jiachao
    Heverhagen, Johannes T.
    Jia, Guang
    Schmalbrock, Petra
    Sammet, Steffen
    Koch, Regina
    Knopp, Michael V.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1448 - 1456
  • [25] Dynamic Contrast-Enhanced Perfusion MRI of High Grade Brain Gliomas Obtained with Arterial or Venous Waveform Input Function
    Filice, Silvano
    Crisi, Girolamo
    JOURNAL OF NEUROIMAGING, 2016, 26 (01) : 124 - 129
  • [26] Automatic Determination of Arterial Input Function for Dynamic Contrast Enhanced MRI in Tumor Assessment
    Chen, Jeremy
    Yao, Jianhua
    Thornasson, David
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT I, PROCEEDINGS, 2008, 5241 : 594 - 601
  • [27] Feasibility testing of a motion phantom for quantitative Dynamic contrast-enhanced MRI
    Lye, Jessica
    Cahoon, Glenn
    Shelton, Nikki
    Alinaghi-Zadeh, Reza
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3895 - S3898
  • [28] Improved reliability of perfusion estimation in dynamic susceptibility contrast MRI by using the arterial input function from dynamic contrast enhanced MRI
    Tseng, Chih-Hsien
    Jaspers, Jaap
    Romero, Alejandra Mendez
    Wielopolski, Piotr
    Smits, Marion
    van Osch, Matthias J. P.
    Vos, Frans
    NMR IN BIOMEDICINE, 2024, 37 (01)
  • [29] Influence of Different Measurement Methods of Arterial Input Function on Quantitative Dynamic Contrast-Enhanced MRI Parameters in Head and Neck Cancer
    Dong, Wanxin
    Volk, Andreas
    Djaroum, Meriem
    Girot, Charly
    Balleyguier, Corinne
    Lebon, Vincent
    Garcia, Gabriel
    Ammari, Samy
    Temam, Stephane
    Gorphe, Philippe
    Wei, Lecong
    Pitre-Champagnat, Stephanie
    Lassau, Nathalie
    Bidault, Francois
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 122 - 132
  • [30] Estimating the arterial input function using two reference tissues in dynamic contrast-enhanced MRI studies: Fundamental concepts and simulations
    Yang, C
    Karczmar, GS
    Medved, M
    Stadler, WM
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1110 - 1117