Effects of Inflow and Radiofrequency Spoiling on the Arterial Input Function in Dynamic Contrast-Enhanced MRI: A Combined Phantom and Simulation Study

被引:35
|
作者
Garpebring, Anders [1 ]
Wirestam, Ronnie [2 ]
Ostlund, Nils [3 ]
Karlsson, Mikael [1 ]
机构
[1] Umea Univ, Dept Radiat Sci, Div Radiat Phys, SE-90187 Umea, Sweden
[2] Lund Univ, Dept Med Radiat Phys, Lund, Sweden
[3] Umea Univ Hosp, Dept Radiat Sci, Div Biomed Engn & Informat, S-90185 Umea, Sweden
基金
瑞典研究理事会;
关键词
dynamic contrast-enhanced MRI; arterial input function; blood flow effects; RF spoiling; HIGH-TEMPORAL-RESOLUTION; FAST GRADIENT-ECHO; BLOOD-VOLUME; IMPROVED ACCURACY; T-1; MEASUREMENT; FLOWING BLOOD; PERMEABILITY; PERFUSION; T1; QUANTIFICATION;
D O I
10.1002/mrm.22760
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The arterial input function is crucial in pharmacokinetic analysis of dynamic contrast-enhanced MRI data. Among other artifacts in arterial input function quantification, the blood inflow effect and nonideal radiofrequency spoiling can induce large measurement errors with subsequent reduction of accuracy in the pharmacokinetic parameters. These errors were investigated for a 3D spoiled gradient-echo sequence using a pulsatile flow phantom and a total of 144 typical imaging settings. In the presence of large inflow effects, results showed poor average accuracy and large spread between imaging settings, when the standard spoiled gradient-echo signal equation was used in the analysis. For example, one of the investigated inflow conditions resulted in a mean error of about 40% and a spread, given by the coefficient of variation, of 20% for K-trans. Minimizing inflow effects by appropriate slice placement, combined with compensation for nonideal radiofrequency spoiling, significantly improved the results, but they remained poorer than without flow (e. g., 3-4 times larger coefficient of variation for K-trans). It was concluded that the 3D spoiled gradient-echo sequence is not optimal for accurate arterial input function quantification and that correction for nonideal radiofrequency spoiling in combination with inflow minimizing slice placement should be used to reduce the errors. Magn Reson Med 65:1670-1679, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:1670 / 1679
页数:10
相关论文
共 50 条
  • [11] Blind estimation of the arterial input function in dynamic contrast-enhanced MRI using purity maximization
    Lin, Yu-Chun
    Chan, Tsung-Han
    Chi, Chong-Yung
    Ng, Shu-Hang
    Liu, Hao-Li
    Wei, Kuo-Chen
    Wai, Yau-Yau
    Wang, Chun-Chieh
    Wang, Jiun-Jie
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1439 - 1449
  • [12] Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging
    Hatef Mehrabian
    Chaitanya Chandrana
    Ian Pang
    Rajiv Chopra
    Anne L. Martel
    European Radiology, 2012, 22 : 1735 - 1747
  • [13] Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging
    Mehrabian, Hatef
    Chandrana, Chaitanya
    Pang, Ian
    Chopra, Rajiv
    Martel, Anne L.
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1735 - 1747
  • [14] Effects of artery input function on dynamic contrast-enhanced MRI for determining grades of gliomas
    Jia, Lin
    Wu, Xia
    Wan, Qian
    Wan, Liwen
    Jia, Wenxiao
    Zhang, Na
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1119):
  • [15] Reproducibility and Optimal Arterial Input Function Selection in Dynamic Contrast-Enhanced Perfusion MRI in the Healthy Brain
    Cramer, Stig P.
    Larsson, Henrik B. W.
    Knudsen, Maria H.
    Simonsen, Helle J.
    Vestergaard, Mark B.
    Lindberg, Ulrich
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1229 - 1240
  • [16] Quantitative dynamic contrast-enhanced MRI for mouse models using automatic detection of the arterial input function
    Kim, Jae-Hun
    Im, Geun Ho
    Yang, Jehoon
    Choi, Dongil
    Lee, Won Jae
    Lee, Jung Hee
    NMR IN BIOMEDICINE, 2012, 25 (04) : 674 - 684
  • [17] Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments
    van Schie, Jeroen J. N.
    Lavini, Cristina
    van Vliet, Lucas J.
    Vos, Frans M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (05) : 1190 - 1196
  • [18] A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model
    Dianning He
    Lisheng Xu
    Wei Qian
    James Clarke
    Xiaobing Fan
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 507 - 518
  • [19] Automatic selection of arterial input function on dynamic contrast-enhanced MR images
    Peruzzo, Denis
    Bertoldo, Alessandra
    Zanderigo, Francesca
    Cobelli, Claudio
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2011, 104 (03) : E148 - E157
  • [20] A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model
    He, Dianning
    Xu, Lisheng
    Qian, Wei
    Clarke, James
    Fan, Xiaobing
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 507 - 518