Accuracy of percutaneous lumbar pedicle screw placement using the oblique or "owl's-eye" view and novel guidance technology

被引:37
|
作者
Idler, Cary [2 ]
Rolfe, Kevin W. [1 ]
Gorek, Josef E. [3 ]
机构
[1] Harbor UCLA Med Ctr, Dept Orthopaed Surg, Torrance, CA 90509 USA
[2] Orthopaed Specialists N Carolina, Wake Forest, NC USA
[3] Kaiser Oakland Med Ctr, Spine Ctr, Oakland, CA USA
关键词
percutaneous pedicle screw; image guidance; owl's-eye projection; lumbar spine; FACET-JOINT VIOLATION; TRANSPEDICULAR INSTRUMENTATION; IMAGE GUIDANCE; SPINAL INSTRUMENTATION; BIOMECHANICAL ANALYSIS; VERTEBRAL ROTATION; FIXATION; COMPLICATIONS; FLUOROSCOPY; NAVIGATION;
D O I
10.3171/2010.4.SPINE09580
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. This study was conducted to assess the in vivo safety and accuracy of percutaneous lumbar pedicle screw placement using the owl's-eye view of the pedicle axis and a new guidance technology system that facilitates orientation of the C-arm into the appropriate fluoroscopic view and the pedicle cannulation tool in the corresponding trajectory. Methods. A total of 326 percutaneous pedicle screws were placed from L-3 to S-1 in 85 consecutive adult patients. Placement was performed using simple coaxial imaging of the pedicle with the owl's-eye fluoroscopic view. Neuro Vision, a new guidance system using accelerometer technology, helped align the C-arm trajectory into the owl's-eye view and the cannulation tool in the same trajectory. Postoperative fine-cut CT scans were acquired to assess screw position. Medical records were reviewed for complications. Results. Five of 326 screws breached a pedicle cortex all breaches were less than 2 mm for an accuracy rate of 98.47%. Five screws violated an adjacent facet joint. All were at the S-1 superior facet and included in a fusion. No screw violated an adjacent mobile facet or disc space. There were no cases of new or worsening neurological symptoms or deficits for an overall clinical accuracy of 100%. Conclusions. The owl's-eye technique of coaxial pedicle imaging with the C-arm fluoroscopy, facilitated by Neuro Vision, is a safe and accurate means by which to place percutaneous pedicle screws for degenerative conditions of the lumbar spine. This is the largest series reported to use the oblique or owl's-eye projection for percutaneous pedicle screw insertion. The accuracy of percutaneous screw insertion with this technique meets or exceeds that of other reported clinical series or techniques. (DOI: 10.3171/2010.4.SPINE09580)
引用
收藏
页码:509 / 515
页数:7
相关论文
共 50 条
  • [31] Accuracy of Percutaneous Pedicle Screw Placement Using Modified Single Anterior- Posterior Fluoroscopy with the C-Arm for the Treatment of Traumatic Thoracic and Lumbar Fractures
    Cui, Kaiying
    Chen, Wenming
    Wang, Mingliang
    Hou, Pengfei
    Tian, Zenghui
    Guo, Jinxing
    Hao, Yanke
    Xu, Zhanwang
    WORLD NEUROSURGERY, 2025, 194
  • [32] A Novel Intraoperative CT Navigation System for Spinal Fusion Surgery in Lumbar Degenerative Disease: Accuracy and Safety of Pedicle Screw Placement
    Kanno, Haruo
    Handa, Kyoichi
    Murotani, Motoki
    Ozawa, Hiroshi
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)
  • [33] Comparison of Open and Percutaneous Lumbar Pedicle Screw Revision Rate Using 3-D Image Guidance and Intraoperative CT
    Santos, Edward Rainier G.
    Sembrano, Jonathan N.
    Yson, Sharon C.
    Polly, David W., Jr.
    ORTHOPEDICS, 2015, 38 (02) : E129 - E134
  • [34] Percutaneous Placement of Iliosacral Screws Under the Guidance of Axial View Projection of the S1 Pedicle: a Case Series
    Yin, Yingchao
    Hou, Zhiyong
    Zhang, Ruipeng
    Jin, Lin
    Chen, Wei
    Zhang, Yingze
    SCIENTIFIC REPORTS, 2017, 7
  • [35] Percutaneous Placement of Iliosacral Screws Under the Guidance of Axial View Projection of the S1 Pedicle: a Case Series
    Yingchao Yin
    Zhiyong Hou
    Ruipeng Zhang
    Lin Jin
    Wei Chen
    Yingze Zhang
    Scientific Reports, 7
  • [36] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Wei-Xing Xu
    Wei-Guo Ding
    Bin Xu
    Tian-Hong Hu
    Hong-Feng Sheng
    Jia-Fu Zhu
    Xiao-Long Zhu
    BMC Musculoskeletal Disorders, 21
  • [37] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Xu, Wei-Xing
    Ding, Wei-Guo
    Xu, Bin
    Hu, Tian-Hong
    Sheng, Hong-Feng
    Zhu, Jia-Fu
    Zhu, Xiao-Long
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [38] Accuracy of Percutaneous Pedicle Screw Placement after Single-Position versus Dual-Position Insertion for Lateral Interbody Fusion and Pedicle Screw Fixation Using Fluoroscopy
    Hiyama, Akihiko
    Katoh, Hiroyuki
    Sakai, Daisuke
    Sato, Masato
    Tanaka, Masahiro
    Watanabe, Masahiko
    ASIAN SPINE JOURNAL, 2022, 16 (01) : 20 - 27
  • [39] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Conrads, Nora
    Grunz, Jan-Peter
    Huflage, Henner
    Luetkens, Karsten Sebastian
    Feldle, Philipp
    Grunz, Katharina
    Koehler, Stefan
    Westermaier, Thomas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3007 - 3013
  • [40] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Nora Conrads
    Jan-Peter Grunz
    Henner Huflage
    Karsten Sebastian Luetkens
    Philipp Feldle
    Katharina Grunz
    Stefan Köhler
    Thomas Westermaier
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3007 - 3013